Cargando…

How Should We Evaluate Syndesmosis Reduction on CT Scan?

CATEGORY: Ankle, Sports, Trauma, Syndesmosis. INTRODUCTION/PURPOSE: Accurate reduction of the syndesmosis is essential to the restoration of normal ankle mechanics, but radiographic evaluation of reduction quality has been demonstrably unreliable. CT imaging has traditionally been considered the gol...

Descripción completa

Detalles Bibliográficos
Autores principales: Abdelaziz, Mohamed E., Hagemeijer, Noortje, Guss, Daniel, El-Hawary, Ahmed, El-Mowafi, Hani, DiGiovanni, Christopher W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8500386/
http://dx.doi.org/10.1177/2473011419S00009
_version_ 1784580434534858752
author Abdelaziz, Mohamed E.
Hagemeijer, Noortje
Guss, Daniel
El-Hawary, Ahmed
El-Mowafi, Hani
DiGiovanni, Christopher W.
author_facet Abdelaziz, Mohamed E.
Hagemeijer, Noortje
Guss, Daniel
El-Hawary, Ahmed
El-Mowafi, Hani
DiGiovanni, Christopher W.
author_sort Abdelaziz, Mohamed E.
collection PubMed
description CATEGORY: Ankle, Sports, Trauma, Syndesmosis. INTRODUCTION/PURPOSE: Accurate reduction of the syndesmosis is essential to the restoration of normal ankle mechanics, but radiographic evaluation of reduction quality has been demonstrably unreliable. CT imaging has traditionally been considered the gold standard, but there is no uniformly accepted method by which to assess syndesmotic reduction on CT. The aim of this study was to evaluate intra- and interobserver reliability of published measurements for evaluation of syndesmosis reduction using weight-bearing CT scan. METHODS: Medical records were reviewed to identify patients who underwent surgical stabilization of a unilateral syndesmotic injury. Exclusion criteria included patients less than 18 years old, ipsilateral pilon fracture, history of contralateral ankle or pilon fracture or syndesmosis injury, BMI >40, and any neurological impairment. Twenty eligible patients were recruited to participate in the study and underwent weight-bearing CT evaluation for both ankles simultaneously. The quality of syndesmotic reduction was evaluated using axial CT images at a level 1 cm proximal to the tibial plafond using nine published radiological measurements (Figure 1). Inter- and intraobserver reliability were assessed for each evaluation method. Side by side method (qualitatively observing the repaired laterality side by side with the contralateral control) was assessed using Kappa interrater agreement, while the reliabilities for all other continuous methods were assessed with interclass correlation coefficients (ICC). RESULTS: The study cohort consisted of ten males and ten females with mean age of 43 years (range, 23-67 years). The intraobserver reliability of the side by side method was 0.49 and 0.24 for the first and second observers respectively, and the interobserver reliability was 0.24. The syndesmotic area showed the highest interobserver reliability (0.96), the highest intraobserver reliability for observer 2 (0.97), and the second highest intraobserver reliability for observer 1 (0.92). Fibular rotation had the second highest interobserver reliability in our results (0.84), with high intraobserver reliability of 0.91 and 0.8 for first and second observers, respectively. The other six radiological measurements had interobserver reliability that ranged between 0.62 and 0.83. CONCLUSION: Qualitatively assessing syndesmotic reduction via side by side comparison with the uninjured ankle had the least intra- and interobserver reliability and should not be relied upon to determine syndesmotic reduction quality. In contradistinction, syndesmotic area calculation showed the highest reliability for evaluating syndesmosis reduction, followed by fibular rotation. Additional efforts should be considered to standardize such measurements within CT image viewers, so they become seamlessly accessible in the clinical setting.
format Online
Article
Text
id pubmed-8500386
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-85003862022-01-28 How Should We Evaluate Syndesmosis Reduction on CT Scan? Abdelaziz, Mohamed E. Hagemeijer, Noortje Guss, Daniel El-Hawary, Ahmed El-Mowafi, Hani DiGiovanni, Christopher W. Foot Ankle Orthop Article CATEGORY: Ankle, Sports, Trauma, Syndesmosis. INTRODUCTION/PURPOSE: Accurate reduction of the syndesmosis is essential to the restoration of normal ankle mechanics, but radiographic evaluation of reduction quality has been demonstrably unreliable. CT imaging has traditionally been considered the gold standard, but there is no uniformly accepted method by which to assess syndesmotic reduction on CT. The aim of this study was to evaluate intra- and interobserver reliability of published measurements for evaluation of syndesmosis reduction using weight-bearing CT scan. METHODS: Medical records were reviewed to identify patients who underwent surgical stabilization of a unilateral syndesmotic injury. Exclusion criteria included patients less than 18 years old, ipsilateral pilon fracture, history of contralateral ankle or pilon fracture or syndesmosis injury, BMI >40, and any neurological impairment. Twenty eligible patients were recruited to participate in the study and underwent weight-bearing CT evaluation for both ankles simultaneously. The quality of syndesmotic reduction was evaluated using axial CT images at a level 1 cm proximal to the tibial plafond using nine published radiological measurements (Figure 1). Inter- and intraobserver reliability were assessed for each evaluation method. Side by side method (qualitatively observing the repaired laterality side by side with the contralateral control) was assessed using Kappa interrater agreement, while the reliabilities for all other continuous methods were assessed with interclass correlation coefficients (ICC). RESULTS: The study cohort consisted of ten males and ten females with mean age of 43 years (range, 23-67 years). The intraobserver reliability of the side by side method was 0.49 and 0.24 for the first and second observers respectively, and the interobserver reliability was 0.24. The syndesmotic area showed the highest interobserver reliability (0.96), the highest intraobserver reliability for observer 2 (0.97), and the second highest intraobserver reliability for observer 1 (0.92). Fibular rotation had the second highest interobserver reliability in our results (0.84), with high intraobserver reliability of 0.91 and 0.8 for first and second observers, respectively. The other six radiological measurements had interobserver reliability that ranged between 0.62 and 0.83. CONCLUSION: Qualitatively assessing syndesmotic reduction via side by side comparison with the uninjured ankle had the least intra- and interobserver reliability and should not be relied upon to determine syndesmotic reduction quality. In contradistinction, syndesmotic area calculation showed the highest reliability for evaluating syndesmosis reduction, followed by fibular rotation. Additional efforts should be considered to standardize such measurements within CT image viewers, so they become seamlessly accessible in the clinical setting. SAGE Publications 2019-10-28 /pmc/articles/PMC8500386/ http://dx.doi.org/10.1177/2473011419S00009 Text en © The Author(s) 2019 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Abdelaziz, Mohamed E.
Hagemeijer, Noortje
Guss, Daniel
El-Hawary, Ahmed
El-Mowafi, Hani
DiGiovanni, Christopher W.
How Should We Evaluate Syndesmosis Reduction on CT Scan?
title How Should We Evaluate Syndesmosis Reduction on CT Scan?
title_full How Should We Evaluate Syndesmosis Reduction on CT Scan?
title_fullStr How Should We Evaluate Syndesmosis Reduction on CT Scan?
title_full_unstemmed How Should We Evaluate Syndesmosis Reduction on CT Scan?
title_short How Should We Evaluate Syndesmosis Reduction on CT Scan?
title_sort how should we evaluate syndesmosis reduction on ct scan?
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8500386/
http://dx.doi.org/10.1177/2473011419S00009
work_keys_str_mv AT abdelazizmohamede howshouldweevaluatesyndesmosisreductiononctscan
AT hagemeijernoortje howshouldweevaluatesyndesmosisreductiononctscan
AT gussdaniel howshouldweevaluatesyndesmosisreductiononctscan
AT elhawaryahmed howshouldweevaluatesyndesmosisreductiononctscan
AT elmowafihani howshouldweevaluatesyndesmosisreductiononctscan
AT digiovannichristopherw howshouldweevaluatesyndesmosisreductiononctscan