Cargando…

Ultrasonic-assisted extraction and automated determination of catalase and lipase activities in bovine and poultry livers using a digital movie-based flow-batch analyzer

An ultrasonic reactor (UR) was developed and coupled to a digital movie-based flow-batch analyzer (DM-FBA) for the ultrasonic-assisted extraction (UAE) and fast determination of catalase and lipase activities in bovine and poultry livers. The lab-made UR mainly consisted of a borosilicate glass cont...

Descripción completa

Detalles Bibliográficos
Autores principales: Siqueira, Lucas A., Almeida, Luciano F., Fernandes, Julys Pablo Atayde, Araújo, Mario Cesar U., Lima, Ricardo Alexandre C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8501505/
https://www.ncbi.nlm.nih.gov/pubmed/34628308
http://dx.doi.org/10.1016/j.ultsonch.2021.105774
_version_ 1784580696565612544
author Siqueira, Lucas A.
Almeida, Luciano F.
Fernandes, Julys Pablo Atayde
Araújo, Mario Cesar U.
Lima, Ricardo Alexandre C.
author_facet Siqueira, Lucas A.
Almeida, Luciano F.
Fernandes, Julys Pablo Atayde
Araújo, Mario Cesar U.
Lima, Ricardo Alexandre C.
author_sort Siqueira, Lucas A.
collection PubMed
description An ultrasonic reactor (UR) was developed and coupled to a digital movie-based flow-batch analyzer (DM-FBA) for the ultrasonic-assisted extraction (UAE) and fast determination of catalase and lipase activities in bovine and poultry livers. The lab-made UR mainly consisted of a borosilicate glass container and a piezoelectric disc. The DM-FBA mainly consisted of a webcam, an ultrasonic actuator controller, a peristaltic pump, six solenoid valves, a valve driver, a mixing chamber, a magnetic stirrer, an Arduino Mega 2560, and a personal computer. This setup, named UR-DM-FBA, was controlled by custom software. Ultrasound (US) frequency, US power, sonication time, and concentration of extraction agent were optimized using the Taguchi method. Experiments at silent conditions (mechanical stirring at 1500 rpm) were carried out to evaluate extraction efficiency. Optimized parameters for the UAE of catalase were US frequency of 30 kHz, 2.0 mL of Triton X-100, sonication time of 270 s, and US power of 10.8 W. For the UAE of lipase, the optimized parameters were US frequency of 20 kHz, 0.30 mL of triethanolamine, sonication time of 270 s, and US power of 18 W. Catalase and lipase activities obtained with the UR were, on average, 1.9 × 10(3)% and 2.0 × 10(3)% higher than those obtained at silent conditions, respectively, which indicates that that the lab-made UR was capable of extracting these enzymes more efficiently. Determinations using the UR-DM-FBA were highly accurate (relative error ranging from −1.98% to 1.96% for bovine catalase, −0.65% to 0.76% for bovine lipase, −2.03 to 2.08% for poultry catalase, and −0.55% to 0.64% for poultry lipase) and precise (overall coefficient of variation <0.02% for bovine and poultry catalase and <0.2% for bovine and poultry lipase). Results obtained with the proposed system and reference methods were in good agreement according to the paired t-test (95% confidence level). High sampling rates (>69 h(−1)) and low sample/reagent consumption (<1.6 mL) were also obtained. Due to the highly efficient UAE, the proposed system can be applied for fast and accurate quantification of lipase and catalase in biological samples with low waste generation.
format Online
Article
Text
id pubmed-8501505
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-85015052021-10-12 Ultrasonic-assisted extraction and automated determination of catalase and lipase activities in bovine and poultry livers using a digital movie-based flow-batch analyzer Siqueira, Lucas A. Almeida, Luciano F. Fernandes, Julys Pablo Atayde Araújo, Mario Cesar U. Lima, Ricardo Alexandre C. Ultrason Sonochem Original Research Article An ultrasonic reactor (UR) was developed and coupled to a digital movie-based flow-batch analyzer (DM-FBA) for the ultrasonic-assisted extraction (UAE) and fast determination of catalase and lipase activities in bovine and poultry livers. The lab-made UR mainly consisted of a borosilicate glass container and a piezoelectric disc. The DM-FBA mainly consisted of a webcam, an ultrasonic actuator controller, a peristaltic pump, six solenoid valves, a valve driver, a mixing chamber, a magnetic stirrer, an Arduino Mega 2560, and a personal computer. This setup, named UR-DM-FBA, was controlled by custom software. Ultrasound (US) frequency, US power, sonication time, and concentration of extraction agent were optimized using the Taguchi method. Experiments at silent conditions (mechanical stirring at 1500 rpm) were carried out to evaluate extraction efficiency. Optimized parameters for the UAE of catalase were US frequency of 30 kHz, 2.0 mL of Triton X-100, sonication time of 270 s, and US power of 10.8 W. For the UAE of lipase, the optimized parameters were US frequency of 20 kHz, 0.30 mL of triethanolamine, sonication time of 270 s, and US power of 18 W. Catalase and lipase activities obtained with the UR were, on average, 1.9 × 10(3)% and 2.0 × 10(3)% higher than those obtained at silent conditions, respectively, which indicates that that the lab-made UR was capable of extracting these enzymes more efficiently. Determinations using the UR-DM-FBA were highly accurate (relative error ranging from −1.98% to 1.96% for bovine catalase, −0.65% to 0.76% for bovine lipase, −2.03 to 2.08% for poultry catalase, and −0.55% to 0.64% for poultry lipase) and precise (overall coefficient of variation <0.02% for bovine and poultry catalase and <0.2% for bovine and poultry lipase). Results obtained with the proposed system and reference methods were in good agreement according to the paired t-test (95% confidence level). High sampling rates (>69 h(−1)) and low sample/reagent consumption (<1.6 mL) were also obtained. Due to the highly efficient UAE, the proposed system can be applied for fast and accurate quantification of lipase and catalase in biological samples with low waste generation. Elsevier 2021-10-02 /pmc/articles/PMC8501505/ /pubmed/34628308 http://dx.doi.org/10.1016/j.ultsonch.2021.105774 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research Article
Siqueira, Lucas A.
Almeida, Luciano F.
Fernandes, Julys Pablo Atayde
Araújo, Mario Cesar U.
Lima, Ricardo Alexandre C.
Ultrasonic-assisted extraction and automated determination of catalase and lipase activities in bovine and poultry livers using a digital movie-based flow-batch analyzer
title Ultrasonic-assisted extraction and automated determination of catalase and lipase activities in bovine and poultry livers using a digital movie-based flow-batch analyzer
title_full Ultrasonic-assisted extraction and automated determination of catalase and lipase activities in bovine and poultry livers using a digital movie-based flow-batch analyzer
title_fullStr Ultrasonic-assisted extraction and automated determination of catalase and lipase activities in bovine and poultry livers using a digital movie-based flow-batch analyzer
title_full_unstemmed Ultrasonic-assisted extraction and automated determination of catalase and lipase activities in bovine and poultry livers using a digital movie-based flow-batch analyzer
title_short Ultrasonic-assisted extraction and automated determination of catalase and lipase activities in bovine and poultry livers using a digital movie-based flow-batch analyzer
title_sort ultrasonic-assisted extraction and automated determination of catalase and lipase activities in bovine and poultry livers using a digital movie-based flow-batch analyzer
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8501505/
https://www.ncbi.nlm.nih.gov/pubmed/34628308
http://dx.doi.org/10.1016/j.ultsonch.2021.105774
work_keys_str_mv AT siqueiralucasa ultrasonicassistedextractionandautomateddeterminationofcatalaseandlipaseactivitiesinbovineandpoultryliversusingadigitalmoviebasedflowbatchanalyzer
AT almeidalucianof ultrasonicassistedextractionandautomateddeterminationofcatalaseandlipaseactivitiesinbovineandpoultryliversusingadigitalmoviebasedflowbatchanalyzer
AT fernandesjulyspabloatayde ultrasonicassistedextractionandautomateddeterminationofcatalaseandlipaseactivitiesinbovineandpoultryliversusingadigitalmoviebasedflowbatchanalyzer
AT araujomariocesaru ultrasonicassistedextractionandautomateddeterminationofcatalaseandlipaseactivitiesinbovineandpoultryliversusingadigitalmoviebasedflowbatchanalyzer
AT limaricardoalexandrec ultrasonicassistedextractionandautomateddeterminationofcatalaseandlipaseactivitiesinbovineandpoultryliversusingadigitalmoviebasedflowbatchanalyzer