Cargando…

Evaluation of clinicoradiological outcomes of lateral vertebral notch referred pedicular screws entry point in subaxial cervical spine by freehand technique

PURPOSE: Cervical pedicle screws (CPSs), though associated with complications and steep learning curve, have significantly increased strength and stability as compared to any other posterior instrumentation methods. Using anatomical referral techniques, pedicle screws can be inserted safely with a h...

Descripción completa

Detalles Bibliográficos
Autores principales: Sandeep, Sonone, Dahapute, Aditya Anand, Balasubramanian, Sai Gautam, Nashikkar, Piyush, Marathe, Nandan, Sonavane, Shalaka Ramesh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8501819/
https://www.ncbi.nlm.nih.gov/pubmed/34728990
http://dx.doi.org/10.4103/jcvjs.jcvjs_28_21
_version_ 1784580759553572864
author Sandeep, Sonone
Dahapute, Aditya Anand
Balasubramanian, Sai Gautam
Nashikkar, Piyush
Marathe, Nandan
Sonavane, Shalaka Ramesh
author_facet Sandeep, Sonone
Dahapute, Aditya Anand
Balasubramanian, Sai Gautam
Nashikkar, Piyush
Marathe, Nandan
Sonavane, Shalaka Ramesh
author_sort Sandeep, Sonone
collection PubMed
description PURPOSE: Cervical pedicle screws (CPSs), though associated with complications and steep learning curve, have significantly increased strength and stability as compared to any other posterior instrumentation methods. Using anatomical referral techniques, pedicle screws can be inserted safely with a high accuracy rate obviating the need for anterior stabilization. Our present study aims to investigate the safety and outcomes of lateral vertebral notch (LVN) referred entry point for subaxial CPSs by freehand technique. MATERIALS AND METHODS: We retrospectively studied 22 patients who underwent CPS fixation. Computed tomography (CT) scan with angiography was done in each case to know the anatomy, characteristics, and anomalies of each pedicle. Postoperative CT scan was done to look for any breach in cervical pedicles. We used free hand technique for insertion of subaxial cervical pedicles taking LVN as a reference point. The authors used the medial wall of the cervical pedicles as a safe guide for the probes that walked along it. RESULTS: Eighty screws were inserted in total in the study group. Mean angle of screw with sagittal axis of vertebrae was 23.43° ± 9.279°. Range of angle used was 6°–40°. Perforation occurred in 11 pedicle screws: C3 (2 out of 8, 25%), c5 (3 out of 20, 15%), and c4 (4 of 22, 18%). Out of 11 perforations, four were complete and seven were partial perforations. One complete medial perforation was associated with radiculopathy that required revision. CONCLUSION: The technique described in the study can be considered relatively safe, easy, and reliable method of inserting cervical pedicle screws with high accuracy (86.25%) and low complication rates (1.25%). However, meticulous preoperative planning is required.
format Online
Article
Text
id pubmed-8501819
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-85018192021-11-01 Evaluation of clinicoradiological outcomes of lateral vertebral notch referred pedicular screws entry point in subaxial cervical spine by freehand technique Sandeep, Sonone Dahapute, Aditya Anand Balasubramanian, Sai Gautam Nashikkar, Piyush Marathe, Nandan Sonavane, Shalaka Ramesh J Craniovertebr Junction Spine Original Article PURPOSE: Cervical pedicle screws (CPSs), though associated with complications and steep learning curve, have significantly increased strength and stability as compared to any other posterior instrumentation methods. Using anatomical referral techniques, pedicle screws can be inserted safely with a high accuracy rate obviating the need for anterior stabilization. Our present study aims to investigate the safety and outcomes of lateral vertebral notch (LVN) referred entry point for subaxial CPSs by freehand technique. MATERIALS AND METHODS: We retrospectively studied 22 patients who underwent CPS fixation. Computed tomography (CT) scan with angiography was done in each case to know the anatomy, characteristics, and anomalies of each pedicle. Postoperative CT scan was done to look for any breach in cervical pedicles. We used free hand technique for insertion of subaxial cervical pedicles taking LVN as a reference point. The authors used the medial wall of the cervical pedicles as a safe guide for the probes that walked along it. RESULTS: Eighty screws were inserted in total in the study group. Mean angle of screw with sagittal axis of vertebrae was 23.43° ± 9.279°. Range of angle used was 6°–40°. Perforation occurred in 11 pedicle screws: C3 (2 out of 8, 25%), c5 (3 out of 20, 15%), and c4 (4 of 22, 18%). Out of 11 perforations, four were complete and seven were partial perforations. One complete medial perforation was associated with radiculopathy that required revision. CONCLUSION: The technique described in the study can be considered relatively safe, easy, and reliable method of inserting cervical pedicle screws with high accuracy (86.25%) and low complication rates (1.25%). However, meticulous preoperative planning is required. Wolters Kluwer - Medknow 2021 2021-09-08 /pmc/articles/PMC8501819/ /pubmed/34728990 http://dx.doi.org/10.4103/jcvjs.jcvjs_28_21 Text en Copyright: © 2021 Journal of Craniovertebral Junction and Spine https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Sandeep, Sonone
Dahapute, Aditya Anand
Balasubramanian, Sai Gautam
Nashikkar, Piyush
Marathe, Nandan
Sonavane, Shalaka Ramesh
Evaluation of clinicoradiological outcomes of lateral vertebral notch referred pedicular screws entry point in subaxial cervical spine by freehand technique
title Evaluation of clinicoradiological outcomes of lateral vertebral notch referred pedicular screws entry point in subaxial cervical spine by freehand technique
title_full Evaluation of clinicoradiological outcomes of lateral vertebral notch referred pedicular screws entry point in subaxial cervical spine by freehand technique
title_fullStr Evaluation of clinicoradiological outcomes of lateral vertebral notch referred pedicular screws entry point in subaxial cervical spine by freehand technique
title_full_unstemmed Evaluation of clinicoradiological outcomes of lateral vertebral notch referred pedicular screws entry point in subaxial cervical spine by freehand technique
title_short Evaluation of clinicoradiological outcomes of lateral vertebral notch referred pedicular screws entry point in subaxial cervical spine by freehand technique
title_sort evaluation of clinicoradiological outcomes of lateral vertebral notch referred pedicular screws entry point in subaxial cervical spine by freehand technique
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8501819/
https://www.ncbi.nlm.nih.gov/pubmed/34728990
http://dx.doi.org/10.4103/jcvjs.jcvjs_28_21
work_keys_str_mv AT sandeepsonone evaluationofclinicoradiologicaloutcomesoflateralvertebralnotchreferredpedicularscrewsentrypointinsubaxialcervicalspinebyfreehandtechnique
AT dahaputeadityaanand evaluationofclinicoradiologicaloutcomesoflateralvertebralnotchreferredpedicularscrewsentrypointinsubaxialcervicalspinebyfreehandtechnique
AT balasubramaniansaigautam evaluationofclinicoradiologicaloutcomesoflateralvertebralnotchreferredpedicularscrewsentrypointinsubaxialcervicalspinebyfreehandtechnique
AT nashikkarpiyush evaluationofclinicoradiologicaloutcomesoflateralvertebralnotchreferredpedicularscrewsentrypointinsubaxialcervicalspinebyfreehandtechnique
AT marathenandan evaluationofclinicoradiologicaloutcomesoflateralvertebralnotchreferredpedicularscrewsentrypointinsubaxialcervicalspinebyfreehandtechnique
AT sonavaneshalakaramesh evaluationofclinicoradiologicaloutcomesoflateralvertebralnotchreferredpedicularscrewsentrypointinsubaxialcervicalspinebyfreehandtechnique