Cargando…

Characterizing the Chemical Profile of Incidental Ultrafine Particles for Toxicity Assessment Using an Aerosol Concentrator

Incidental ultrafine particles (UFPs) constitute a key pollutant in industrial workplaces. However, characterizing their chemical properties for exposure and toxicity assessments still remains a challenge. In this work, the performance of an aerosol concentrator (Versatile Aerosol Concentration Enri...

Descripción completa

Detalles Bibliográficos
Autores principales: Viana, M, Salmatonidis, A, Bezantakos, S, Ribalta, C, Moreno, N, Córdoba, P, Cassee, F R, Boere, J, Fraga, S, Teixeira, J P, Bessa, M J, Monfort, E
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8501988/
https://www.ncbi.nlm.nih.gov/pubmed/34314505
http://dx.doi.org/10.1093/annweh/wxab011
_version_ 1784580789115027456
author Viana, M
Salmatonidis, A
Bezantakos, S
Ribalta, C
Moreno, N
Córdoba, P
Cassee, F R
Boere, J
Fraga, S
Teixeira, J P
Bessa, M J
Monfort, E
author_facet Viana, M
Salmatonidis, A
Bezantakos, S
Ribalta, C
Moreno, N
Córdoba, P
Cassee, F R
Boere, J
Fraga, S
Teixeira, J P
Bessa, M J
Monfort, E
author_sort Viana, M
collection PubMed
description Incidental ultrafine particles (UFPs) constitute a key pollutant in industrial workplaces. However, characterizing their chemical properties for exposure and toxicity assessments still remains a challenge. In this work, the performance of an aerosol concentrator (Versatile Aerosol Concentration Enrichment System, VACES) was assessed to simultaneously sample UFPs on filter substrates (for chemical analysis) and as liquid suspensions (for toxicity assessment), in a high UFP concentration scenario. An industrial case study was selected where metal-containing UFPs were emitted during thermal spraying of ceramic coatings. Results evidenced the comparability of the VACES system with online monitors in terms of UFP particle mass (for concentrations up to 95 µg UFP/m(3)) and between filters and liquid suspensions, in terms of particle composition (for concentrations up to 1000 µg/m(3)). This supports the applicability of this tool for UFP collection in view of chemical and toxicological characterization for incidental UFPs. In the industrial setting evaluated, results showed that the spraying temperature was a driver of fractionation of metals between UF (<0.2 µm) and fine (0.2–2.5 µm) particles. Potentially health hazardous metals (Ni, Cr) were enriched in UFPs and depleted in the fine particle fraction. Metals vaporized at high temperatures and concentrated in the UF fraction through nucleation processes. Results evidenced the need to understand incidental particle formation mechanisms due to their direct implications on particle composition and, thus, exposure. It is advisable that personal exposure and subsequent risk assessments in occupational settings should include dedicated metrics to monitor UFPs (especially, incidental).
format Online
Article
Text
id pubmed-8501988
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-85019882021-10-12 Characterizing the Chemical Profile of Incidental Ultrafine Particles for Toxicity Assessment Using an Aerosol Concentrator Viana, M Salmatonidis, A Bezantakos, S Ribalta, C Moreno, N Córdoba, P Cassee, F R Boere, J Fraga, S Teixeira, J P Bessa, M J Monfort, E Ann Work Expo Health Original Articles Incidental ultrafine particles (UFPs) constitute a key pollutant in industrial workplaces. However, characterizing their chemical properties for exposure and toxicity assessments still remains a challenge. In this work, the performance of an aerosol concentrator (Versatile Aerosol Concentration Enrichment System, VACES) was assessed to simultaneously sample UFPs on filter substrates (for chemical analysis) and as liquid suspensions (for toxicity assessment), in a high UFP concentration scenario. An industrial case study was selected where metal-containing UFPs were emitted during thermal spraying of ceramic coatings. Results evidenced the comparability of the VACES system with online monitors in terms of UFP particle mass (for concentrations up to 95 µg UFP/m(3)) and between filters and liquid suspensions, in terms of particle composition (for concentrations up to 1000 µg/m(3)). This supports the applicability of this tool for UFP collection in view of chemical and toxicological characterization for incidental UFPs. In the industrial setting evaluated, results showed that the spraying temperature was a driver of fractionation of metals between UF (<0.2 µm) and fine (0.2–2.5 µm) particles. Potentially health hazardous metals (Ni, Cr) were enriched in UFPs and depleted in the fine particle fraction. Metals vaporized at high temperatures and concentrated in the UF fraction through nucleation processes. Results evidenced the need to understand incidental particle formation mechanisms due to their direct implications on particle composition and, thus, exposure. It is advisable that personal exposure and subsequent risk assessments in occupational settings should include dedicated metrics to monitor UFPs (especially, incidental). Oxford University Press 2021-07-27 /pmc/articles/PMC8501988/ /pubmed/34314505 http://dx.doi.org/10.1093/annweh/wxab011 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of the British Occupational Hygiene Society. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Original Articles
Viana, M
Salmatonidis, A
Bezantakos, S
Ribalta, C
Moreno, N
Córdoba, P
Cassee, F R
Boere, J
Fraga, S
Teixeira, J P
Bessa, M J
Monfort, E
Characterizing the Chemical Profile of Incidental Ultrafine Particles for Toxicity Assessment Using an Aerosol Concentrator
title Characterizing the Chemical Profile of Incidental Ultrafine Particles for Toxicity Assessment Using an Aerosol Concentrator
title_full Characterizing the Chemical Profile of Incidental Ultrafine Particles for Toxicity Assessment Using an Aerosol Concentrator
title_fullStr Characterizing the Chemical Profile of Incidental Ultrafine Particles for Toxicity Assessment Using an Aerosol Concentrator
title_full_unstemmed Characterizing the Chemical Profile of Incidental Ultrafine Particles for Toxicity Assessment Using an Aerosol Concentrator
title_short Characterizing the Chemical Profile of Incidental Ultrafine Particles for Toxicity Assessment Using an Aerosol Concentrator
title_sort characterizing the chemical profile of incidental ultrafine particles for toxicity assessment using an aerosol concentrator
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8501988/
https://www.ncbi.nlm.nih.gov/pubmed/34314505
http://dx.doi.org/10.1093/annweh/wxab011
work_keys_str_mv AT vianam characterizingthechemicalprofileofincidentalultrafineparticlesfortoxicityassessmentusinganaerosolconcentrator
AT salmatonidisa characterizingthechemicalprofileofincidentalultrafineparticlesfortoxicityassessmentusinganaerosolconcentrator
AT bezantakoss characterizingthechemicalprofileofincidentalultrafineparticlesfortoxicityassessmentusinganaerosolconcentrator
AT ribaltac characterizingthechemicalprofileofincidentalultrafineparticlesfortoxicityassessmentusinganaerosolconcentrator
AT morenon characterizingthechemicalprofileofincidentalultrafineparticlesfortoxicityassessmentusinganaerosolconcentrator
AT cordobap characterizingthechemicalprofileofincidentalultrafineparticlesfortoxicityassessmentusinganaerosolconcentrator
AT casseefr characterizingthechemicalprofileofincidentalultrafineparticlesfortoxicityassessmentusinganaerosolconcentrator
AT boerej characterizingthechemicalprofileofincidentalultrafineparticlesfortoxicityassessmentusinganaerosolconcentrator
AT fragas characterizingthechemicalprofileofincidentalultrafineparticlesfortoxicityassessmentusinganaerosolconcentrator
AT teixeirajp characterizingthechemicalprofileofincidentalultrafineparticlesfortoxicityassessmentusinganaerosolconcentrator
AT bessamj characterizingthechemicalprofileofincidentalultrafineparticlesfortoxicityassessmentusinganaerosolconcentrator
AT monforte characterizingthechemicalprofileofincidentalultrafineparticlesfortoxicityassessmentusinganaerosolconcentrator