Isotope-Dilution Gas Chromatography-Mass Spectrometry Method for the Selective Detection of Nicotine and Menthol in E-Cigarette, or Vaping, Product Liquids and Aerosols
We developed a quantitative method for analyzing nicotine and menthol in e-cigarette, or vaping, products (EVPs). These products may adversely impact health through inhalational exposure to addictive and harmful chemicals. The presence of unknown substances in do-it-yourself e-liquids, counterfeits,...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8503638/ https://www.ncbi.nlm.nih.gov/pubmed/34646814 http://dx.doi.org/10.3389/fchem.2021.754096 |
_version_ | 1784581169771184128 |
---|---|
author | Pérez, José J. Watson, Clifford H. Blount, Benjamin C. Valentín-Blasini, Liza |
author_facet | Pérez, José J. Watson, Clifford H. Blount, Benjamin C. Valentín-Blasini, Liza |
author_sort | Pérez, José J. |
collection | PubMed |
description | We developed a quantitative method for analyzing nicotine and menthol in e-cigarette, or vaping, products (EVPs). These products may adversely impact health through inhalational exposure to addictive and harmful chemicals. The presence of unknown substances in do-it-yourself e-liquids, counterfeits, or unregulated products may increase exposure to harmful chemicals, as underscored by the 2019 EVP use-associated lung injury (EVALI) outbreak. To minimize these risks, it is important to accurately quantify nicotine and menthol in e-liquids and aerosol emissions to evaluate EVP authenticity, verify product label accuracy, and identify potentially hazardous products. We developed a simple, versatile, high-throughput method using isotope-dilution gas chromatography-mass spectrometry for quantifying nicotine and menthol concentrations in both e-liquid contents and machine-generated aerosol emissions of EVPs. Rigorous validation has demonstrated that the method is specific, precise (CV<2.71%), accurate (percent error ≤7.0%), and robust. Linear calibration ranges from 0.01 to 1.00 mg/ml for both analytes was achieved, corresponding to expected analyte levels in e-liquids and machine-generated EVP aerosols. Limits of detection (LODs) in the final 10-ml sample extract were 0.4 μg/ml for nicotine and 0.2 μg/ml for menthol. The method was used to analyze aerosol emissions of 141 EVPs associated with the 2019 EVALI outbreak; detectable levels of nicotine (2.19–59.5 mg/g of aerosol) and menthol (1.09–10.69 mg/g of aerosol) were observed in 28 and 11%, respectively, of the samples analyzed. Nicotine was not detected in any of the tetrahydrocannabinol (THC), cannabidiol (CBD), or oil-based products, while menthol (2.95 mg/g of aerosol) was only detected in one of these products (THC-labeled). The analytical method can be used to quantify nicotine and menthol concentrations in the e-liquids and aerosols from a range of EVPs, and these findings highlight a difference between e-cigarette and other vaping products. |
format | Online Article Text |
id | pubmed-8503638 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-85036382021-10-12 Isotope-Dilution Gas Chromatography-Mass Spectrometry Method for the Selective Detection of Nicotine and Menthol in E-Cigarette, or Vaping, Product Liquids and Aerosols Pérez, José J. Watson, Clifford H. Blount, Benjamin C. Valentín-Blasini, Liza Front Chem Chemistry We developed a quantitative method for analyzing nicotine and menthol in e-cigarette, or vaping, products (EVPs). These products may adversely impact health through inhalational exposure to addictive and harmful chemicals. The presence of unknown substances in do-it-yourself e-liquids, counterfeits, or unregulated products may increase exposure to harmful chemicals, as underscored by the 2019 EVP use-associated lung injury (EVALI) outbreak. To minimize these risks, it is important to accurately quantify nicotine and menthol in e-liquids and aerosol emissions to evaluate EVP authenticity, verify product label accuracy, and identify potentially hazardous products. We developed a simple, versatile, high-throughput method using isotope-dilution gas chromatography-mass spectrometry for quantifying nicotine and menthol concentrations in both e-liquid contents and machine-generated aerosol emissions of EVPs. Rigorous validation has demonstrated that the method is specific, precise (CV<2.71%), accurate (percent error ≤7.0%), and robust. Linear calibration ranges from 0.01 to 1.00 mg/ml for both analytes was achieved, corresponding to expected analyte levels in e-liquids and machine-generated EVP aerosols. Limits of detection (LODs) in the final 10-ml sample extract were 0.4 μg/ml for nicotine and 0.2 μg/ml for menthol. The method was used to analyze aerosol emissions of 141 EVPs associated with the 2019 EVALI outbreak; detectable levels of nicotine (2.19–59.5 mg/g of aerosol) and menthol (1.09–10.69 mg/g of aerosol) were observed in 28 and 11%, respectively, of the samples analyzed. Nicotine was not detected in any of the tetrahydrocannabinol (THC), cannabidiol (CBD), or oil-based products, while menthol (2.95 mg/g of aerosol) was only detected in one of these products (THC-labeled). The analytical method can be used to quantify nicotine and menthol concentrations in the e-liquids and aerosols from a range of EVPs, and these findings highlight a difference between e-cigarette and other vaping products. Frontiers Media S.A. 2021-09-27 /pmc/articles/PMC8503638/ /pubmed/34646814 http://dx.doi.org/10.3389/fchem.2021.754096 Text en Copyright © 2021 Pérez, Watson, Blount and Valentín-Blasini. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Chemistry Pérez, José J. Watson, Clifford H. Blount, Benjamin C. Valentín-Blasini, Liza Isotope-Dilution Gas Chromatography-Mass Spectrometry Method for the Selective Detection of Nicotine and Menthol in E-Cigarette, or Vaping, Product Liquids and Aerosols |
title | Isotope-Dilution Gas Chromatography-Mass Spectrometry Method for the Selective Detection of Nicotine and Menthol in E-Cigarette, or Vaping, Product Liquids and Aerosols |
title_full | Isotope-Dilution Gas Chromatography-Mass Spectrometry Method for the Selective Detection of Nicotine and Menthol in E-Cigarette, or Vaping, Product Liquids and Aerosols |
title_fullStr | Isotope-Dilution Gas Chromatography-Mass Spectrometry Method for the Selective Detection of Nicotine and Menthol in E-Cigarette, or Vaping, Product Liquids and Aerosols |
title_full_unstemmed | Isotope-Dilution Gas Chromatography-Mass Spectrometry Method for the Selective Detection of Nicotine and Menthol in E-Cigarette, or Vaping, Product Liquids and Aerosols |
title_short | Isotope-Dilution Gas Chromatography-Mass Spectrometry Method for the Selective Detection of Nicotine and Menthol in E-Cigarette, or Vaping, Product Liquids and Aerosols |
title_sort | isotope-dilution gas chromatography-mass spectrometry method for the selective detection of nicotine and menthol in e-cigarette, or vaping, product liquids and aerosols |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8503638/ https://www.ncbi.nlm.nih.gov/pubmed/34646814 http://dx.doi.org/10.3389/fchem.2021.754096 |
work_keys_str_mv | AT perezjosej isotopedilutiongaschromatographymassspectrometrymethodfortheselectivedetectionofnicotineandmentholinecigaretteorvapingproductliquidsandaerosols AT watsoncliffordh isotopedilutiongaschromatographymassspectrometrymethodfortheselectivedetectionofnicotineandmentholinecigaretteorvapingproductliquidsandaerosols AT blountbenjaminc isotopedilutiongaschromatographymassspectrometrymethodfortheselectivedetectionofnicotineandmentholinecigaretteorvapingproductliquidsandaerosols AT valentinblasiniliza isotopedilutiongaschromatographymassspectrometrymethodfortheselectivedetectionofnicotineandmentholinecigaretteorvapingproductliquidsandaerosols |