Cargando…

Monte Carlo Dose Calculation Using MRI Based Synthetic CT Generated by Fully Convolutional Neural Network for Gamma Knife Radiosurgery

The aim of this work is to study the dosimetric effect from generated synthetic computed tomography (sCT) from magnetic resonance (MR) images using a deep learning algorithm for Gamma Knife (GK) stereotactic radiosurgery (SRS). The Monte Carlo (MC) method is used for dose calculations. Thirty patien...

Descripción completa

Detalles Bibliográficos
Autores principales: Yuan, Jiankui, Fredman, Elisha, Jin, Jian-Yue, Choi, Serah, Mansur, David, Sloan, Andrew, Machtay, Mitchell, Zheng, Yiran
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8504229/
https://www.ncbi.nlm.nih.gov/pubmed/34632872
http://dx.doi.org/10.1177/15330338211046433
_version_ 1784581288956526592
author Yuan, Jiankui
Fredman, Elisha
Jin, Jian-Yue
Choi, Serah
Mansur, David
Sloan, Andrew
Machtay, Mitchell
Zheng, Yiran
author_facet Yuan, Jiankui
Fredman, Elisha
Jin, Jian-Yue
Choi, Serah
Mansur, David
Sloan, Andrew
Machtay, Mitchell
Zheng, Yiran
author_sort Yuan, Jiankui
collection PubMed
description The aim of this work is to study the dosimetric effect from generated synthetic computed tomography (sCT) from magnetic resonance (MR) images using a deep learning algorithm for Gamma Knife (GK) stereotactic radiosurgery (SRS). The Monte Carlo (MC) method is used for dose calculations. Thirty patients were retrospectively selected with our institution IRB’s approval. All patients were treated with GK SRS based on T1-weighted MR images and also underwent conventional external beam treatment with a CT scan. Image datasets were preprocessed with registration and were normalized to obtain similar intensity for the pairs of MR and CT images. A deep convolutional neural network arranged in an encoder–decoder fashion was used to learn the direct mapping from MR to the corresponding CT. A number of metrics including the voxel-wise mean error (ME) and mean absolute error (MAE) were used for evaluating the difference between generated sCT and the true CT. To study the dosimetric accuracy, MC simulations were performed based on the true CT and sCT using the same treatment parameters. The method produced an MAE of 86.6 ± 34.1 Hundsfield units (HU) and a mean squared error (MSE) of 160.9 ± 32.8. The mean Dice similarity coefficient was 0.82 ± 0.05 for HU > 200. The difference for dose-volume parameter D95 between the ground true dose and the dose calculated with sCT was 1.1% if a synthetic CT-to-density table was used, and 4.9% compared with the calculations based on the water-brain phantom.
format Online
Article
Text
id pubmed-8504229
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-85042292021-10-12 Monte Carlo Dose Calculation Using MRI Based Synthetic CT Generated by Fully Convolutional Neural Network for Gamma Knife Radiosurgery Yuan, Jiankui Fredman, Elisha Jin, Jian-Yue Choi, Serah Mansur, David Sloan, Andrew Machtay, Mitchell Zheng, Yiran Technol Cancer Res Treat Original Article The aim of this work is to study the dosimetric effect from generated synthetic computed tomography (sCT) from magnetic resonance (MR) images using a deep learning algorithm for Gamma Knife (GK) stereotactic radiosurgery (SRS). The Monte Carlo (MC) method is used for dose calculations. Thirty patients were retrospectively selected with our institution IRB’s approval. All patients were treated with GK SRS based on T1-weighted MR images and also underwent conventional external beam treatment with a CT scan. Image datasets were preprocessed with registration and were normalized to obtain similar intensity for the pairs of MR and CT images. A deep convolutional neural network arranged in an encoder–decoder fashion was used to learn the direct mapping from MR to the corresponding CT. A number of metrics including the voxel-wise mean error (ME) and mean absolute error (MAE) were used for evaluating the difference between generated sCT and the true CT. To study the dosimetric accuracy, MC simulations were performed based on the true CT and sCT using the same treatment parameters. The method produced an MAE of 86.6 ± 34.1 Hundsfield units (HU) and a mean squared error (MSE) of 160.9 ± 32.8. The mean Dice similarity coefficient was 0.82 ± 0.05 for HU > 200. The difference for dose-volume parameter D95 between the ground true dose and the dose calculated with sCT was 1.1% if a synthetic CT-to-density table was used, and 4.9% compared with the calculations based on the water-brain phantom. SAGE Publications 2021-10-09 /pmc/articles/PMC8504229/ /pubmed/34632872 http://dx.doi.org/10.1177/15330338211046433 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Article
Yuan, Jiankui
Fredman, Elisha
Jin, Jian-Yue
Choi, Serah
Mansur, David
Sloan, Andrew
Machtay, Mitchell
Zheng, Yiran
Monte Carlo Dose Calculation Using MRI Based Synthetic CT Generated by Fully Convolutional Neural Network for Gamma Knife Radiosurgery
title Monte Carlo Dose Calculation Using MRI Based Synthetic CT Generated by Fully Convolutional Neural Network for Gamma Knife Radiosurgery
title_full Monte Carlo Dose Calculation Using MRI Based Synthetic CT Generated by Fully Convolutional Neural Network for Gamma Knife Radiosurgery
title_fullStr Monte Carlo Dose Calculation Using MRI Based Synthetic CT Generated by Fully Convolutional Neural Network for Gamma Knife Radiosurgery
title_full_unstemmed Monte Carlo Dose Calculation Using MRI Based Synthetic CT Generated by Fully Convolutional Neural Network for Gamma Knife Radiosurgery
title_short Monte Carlo Dose Calculation Using MRI Based Synthetic CT Generated by Fully Convolutional Neural Network for Gamma Knife Radiosurgery
title_sort monte carlo dose calculation using mri based synthetic ct generated by fully convolutional neural network for gamma knife radiosurgery
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8504229/
https://www.ncbi.nlm.nih.gov/pubmed/34632872
http://dx.doi.org/10.1177/15330338211046433
work_keys_str_mv AT yuanjiankui montecarlodosecalculationusingmribasedsyntheticctgeneratedbyfullyconvolutionalneuralnetworkforgammakniferadiosurgery
AT fredmanelisha montecarlodosecalculationusingmribasedsyntheticctgeneratedbyfullyconvolutionalneuralnetworkforgammakniferadiosurgery
AT jinjianyue montecarlodosecalculationusingmribasedsyntheticctgeneratedbyfullyconvolutionalneuralnetworkforgammakniferadiosurgery
AT choiserah montecarlodosecalculationusingmribasedsyntheticctgeneratedbyfullyconvolutionalneuralnetworkforgammakniferadiosurgery
AT mansurdavid montecarlodosecalculationusingmribasedsyntheticctgeneratedbyfullyconvolutionalneuralnetworkforgammakniferadiosurgery
AT sloanandrew montecarlodosecalculationusingmribasedsyntheticctgeneratedbyfullyconvolutionalneuralnetworkforgammakniferadiosurgery
AT machtaymitchell montecarlodosecalculationusingmribasedsyntheticctgeneratedbyfullyconvolutionalneuralnetworkforgammakniferadiosurgery
AT zhengyiran montecarlodosecalculationusingmribasedsyntheticctgeneratedbyfullyconvolutionalneuralnetworkforgammakniferadiosurgery