Complications after Dynamic Hip Screw Osteosynthesis of Proximal Femoral Fractures at Army Instructional Hospital-Libreville
The DHS system is an effective means of open reduction and internal fixation of proximal femur fractures. Postoperative complications are little described and deserve to be studied for better preventive and curative treatment. We report the observations of five (5) patients who presented postoperati...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8505106/ https://www.ncbi.nlm.nih.gov/pubmed/34646582 http://dx.doi.org/10.1155/2021/4177203 |
_version_ | 1784581457103028224 |
---|---|
author | Bombah, F. M. Diawara, M. Ekani, B. Y. Nana, T. Mikiela, A. |
author_facet | Bombah, F. M. Diawara, M. Ekani, B. Y. Nana, T. Mikiela, A. |
author_sort | Bombah, F. M. |
collection | PubMed |
description | The DHS system is an effective means of open reduction and internal fixation of proximal femur fractures. Postoperative complications are little described and deserve to be studied for better preventive and curative treatment. We report the observations of five (5) patients who presented postoperative complications specific to the DHS system at army instructional Hospital-Libreville. These described complications are related to deterioration of internal fixation leading to callus, nonunion, or infection. Those found are the cut out phenomenon, avascular necrosis of the femoral head, and the fracture of the DHS system. All these complications required surgical revision without functional repercussions at the last follow-up. Complications of internal fixation by the DHS system can be avoided by rigorous asepsis, adequate indications for surgery, and rigorous surgical techniques. Good management can restore hip function. |
format | Online Article Text |
id | pubmed-8505106 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-85051062021-10-12 Complications after Dynamic Hip Screw Osteosynthesis of Proximal Femoral Fractures at Army Instructional Hospital-Libreville Bombah, F. M. Diawara, M. Ekani, B. Y. Nana, T. Mikiela, A. Case Rep Orthop Case Series The DHS system is an effective means of open reduction and internal fixation of proximal femur fractures. Postoperative complications are little described and deserve to be studied for better preventive and curative treatment. We report the observations of five (5) patients who presented postoperative complications specific to the DHS system at army instructional Hospital-Libreville. These described complications are related to deterioration of internal fixation leading to callus, nonunion, or infection. Those found are the cut out phenomenon, avascular necrosis of the femoral head, and the fracture of the DHS system. All these complications required surgical revision without functional repercussions at the last follow-up. Complications of internal fixation by the DHS system can be avoided by rigorous asepsis, adequate indications for surgery, and rigorous surgical techniques. Good management can restore hip function. Hindawi 2021-10-04 /pmc/articles/PMC8505106/ /pubmed/34646582 http://dx.doi.org/10.1155/2021/4177203 Text en Copyright © 2021 F. M. Bombah et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Series Bombah, F. M. Diawara, M. Ekani, B. Y. Nana, T. Mikiela, A. Complications after Dynamic Hip Screw Osteosynthesis of Proximal Femoral Fractures at Army Instructional Hospital-Libreville |
title | Complications after Dynamic Hip Screw Osteosynthesis of Proximal Femoral Fractures at Army Instructional Hospital-Libreville |
title_full | Complications after Dynamic Hip Screw Osteosynthesis of Proximal Femoral Fractures at Army Instructional Hospital-Libreville |
title_fullStr | Complications after Dynamic Hip Screw Osteosynthesis of Proximal Femoral Fractures at Army Instructional Hospital-Libreville |
title_full_unstemmed | Complications after Dynamic Hip Screw Osteosynthesis of Proximal Femoral Fractures at Army Instructional Hospital-Libreville |
title_short | Complications after Dynamic Hip Screw Osteosynthesis of Proximal Femoral Fractures at Army Instructional Hospital-Libreville |
title_sort | complications after dynamic hip screw osteosynthesis of proximal femoral fractures at army instructional hospital-libreville |
topic | Case Series |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8505106/ https://www.ncbi.nlm.nih.gov/pubmed/34646582 http://dx.doi.org/10.1155/2021/4177203 |
work_keys_str_mv | AT bombahfm complicationsafterdynamichipscrewosteosynthesisofproximalfemoralfracturesatarmyinstructionalhospitallibreville AT diawaram complicationsafterdynamichipscrewosteosynthesisofproximalfemoralfracturesatarmyinstructionalhospitallibreville AT ekaniby complicationsafterdynamichipscrewosteosynthesisofproximalfemoralfracturesatarmyinstructionalhospitallibreville AT nanat complicationsafterdynamichipscrewosteosynthesisofproximalfemoralfracturesatarmyinstructionalhospitallibreville AT mikielaa complicationsafterdynamichipscrewosteosynthesisofproximalfemoralfracturesatarmyinstructionalhospitallibreville |