Cargando…

Determination of Face and Content Validity of Cadaveric Model for Holmium Anatomic Endoscopic Enucleation of the Prostate Training: An ESUT AEEP Group Study

BACKGROUND: Bench and virtual reality nonbiological simulator models for anatomic endoscopic enucleation of the prostate (AEEP) surgery have been reported in the literature. These models are acceptable but have limited practical applications. OBJECTIVE: To validate a fresh-frozen human cadaver model...

Descripción completa

Detalles Bibliográficos
Autores principales: Tunc, Lutfi, Bozzini, Giorgio, Scoffone, Cesare Marco, Guven, Selcuk, Hermann, Thomas, Porreca, Angelo, Misrai, Vincent, Ahyai, Sascha, Zor, Murat, Aksoy, Emin, Gozen, Ali S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8505198/
https://www.ncbi.nlm.nih.gov/pubmed/34667956
http://dx.doi.org/10.1016/j.euros.2021.07.005
_version_ 1784581479555137536
author Tunc, Lutfi
Bozzini, Giorgio
Scoffone, Cesare Marco
Guven, Selcuk
Hermann, Thomas
Porreca, Angelo
Misrai, Vincent
Ahyai, Sascha
Zor, Murat
Aksoy, Emin
Gozen, Ali S.
author_facet Tunc, Lutfi
Bozzini, Giorgio
Scoffone, Cesare Marco
Guven, Selcuk
Hermann, Thomas
Porreca, Angelo
Misrai, Vincent
Ahyai, Sascha
Zor, Murat
Aksoy, Emin
Gozen, Ali S.
author_sort Tunc, Lutfi
collection PubMed
description BACKGROUND: Bench and virtual reality nonbiological simulator models for anatomic endoscopic enucleation of the prostate (AEEP) surgery have been reported in the literature. These models are acceptable but have limited practical applications. OBJECTIVE: To validate a fresh-frozen human cadaver model for holmium AEEP training and assess its content validity. DESIGN, SETTING, AND PARTICIPANTS: Holmium AEEP operations on fresh-frozen cadavers performed by an experienced surgeon were recorded, and a video, including the main steps of the operation, was produced. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: The video and an accompanying questionnaire were subsequently distributed electronically to ESUT AEEP study group experts and associates (N = 32) for assessment of the AEEP training model. A ten-point Likert global rating scale was used to measure the content validity. RESULTS AND LIMITATIONS: A total of 26 answers were returned (81%). The experts agreed on the model’s suitability for AEEP training (mean Likert score: 8). According to the responses, “identifying anatomic structures and landmarks” was the most valuable aspect of the model in terms of AEEP training (median Likert score: 9). Conversely, the experts found the model’s ability, in terms of demonstrating laser and tissue reactions, to be weak (median Likert score: 6) CONCLUSIONS: Based on the content validity assessment, the fresh-frozen cadaver-training model for laser AEEP seems to be a promising model for demonstrating and learning the correct prostate enucleation technique. PATIENT SUMMARY: An increasing number of researchers have proposed that anatomic endoscopic enucleation of the prostate (AEEP) should replace transurethral resection of the prostate surgery and become the gold standard for treatment of bladder outlet obstruction due to benign prostatic hyperplasia. AEEP requires anatomic familiarity for enucleation, technical knowledge, and a solid training program before starting with the first cases. This is the first cadaver study to assess the content validity of a fresh-frozen human cadaver model for AEEP training.
format Online
Article
Text
id pubmed-8505198
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-85051982021-10-18 Determination of Face and Content Validity of Cadaveric Model for Holmium Anatomic Endoscopic Enucleation of the Prostate Training: An ESUT AEEP Group Study Tunc, Lutfi Bozzini, Giorgio Scoffone, Cesare Marco Guven, Selcuk Hermann, Thomas Porreca, Angelo Misrai, Vincent Ahyai, Sascha Zor, Murat Aksoy, Emin Gozen, Ali S. Eur Urol Open Sci Education BACKGROUND: Bench and virtual reality nonbiological simulator models for anatomic endoscopic enucleation of the prostate (AEEP) surgery have been reported in the literature. These models are acceptable but have limited practical applications. OBJECTIVE: To validate a fresh-frozen human cadaver model for holmium AEEP training and assess its content validity. DESIGN, SETTING, AND PARTICIPANTS: Holmium AEEP operations on fresh-frozen cadavers performed by an experienced surgeon were recorded, and a video, including the main steps of the operation, was produced. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: The video and an accompanying questionnaire were subsequently distributed electronically to ESUT AEEP study group experts and associates (N = 32) for assessment of the AEEP training model. A ten-point Likert global rating scale was used to measure the content validity. RESULTS AND LIMITATIONS: A total of 26 answers were returned (81%). The experts agreed on the model’s suitability for AEEP training (mean Likert score: 8). According to the responses, “identifying anatomic structures and landmarks” was the most valuable aspect of the model in terms of AEEP training (median Likert score: 9). Conversely, the experts found the model’s ability, in terms of demonstrating laser and tissue reactions, to be weak (median Likert score: 6) CONCLUSIONS: Based on the content validity assessment, the fresh-frozen cadaver-training model for laser AEEP seems to be a promising model for demonstrating and learning the correct prostate enucleation technique. PATIENT SUMMARY: An increasing number of researchers have proposed that anatomic endoscopic enucleation of the prostate (AEEP) should replace transurethral resection of the prostate surgery and become the gold standard for treatment of bladder outlet obstruction due to benign prostatic hyperplasia. AEEP requires anatomic familiarity for enucleation, technical knowledge, and a solid training program before starting with the first cases. This is the first cadaver study to assess the content validity of a fresh-frozen human cadaver model for AEEP training. Elsevier 2021-08-18 /pmc/articles/PMC8505198/ /pubmed/34667956 http://dx.doi.org/10.1016/j.euros.2021.07.005 Text en © 2021 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Education
Tunc, Lutfi
Bozzini, Giorgio
Scoffone, Cesare Marco
Guven, Selcuk
Hermann, Thomas
Porreca, Angelo
Misrai, Vincent
Ahyai, Sascha
Zor, Murat
Aksoy, Emin
Gozen, Ali S.
Determination of Face and Content Validity of Cadaveric Model for Holmium Anatomic Endoscopic Enucleation of the Prostate Training: An ESUT AEEP Group Study
title Determination of Face and Content Validity of Cadaveric Model for Holmium Anatomic Endoscopic Enucleation of the Prostate Training: An ESUT AEEP Group Study
title_full Determination of Face and Content Validity of Cadaveric Model for Holmium Anatomic Endoscopic Enucleation of the Prostate Training: An ESUT AEEP Group Study
title_fullStr Determination of Face and Content Validity of Cadaveric Model for Holmium Anatomic Endoscopic Enucleation of the Prostate Training: An ESUT AEEP Group Study
title_full_unstemmed Determination of Face and Content Validity of Cadaveric Model for Holmium Anatomic Endoscopic Enucleation of the Prostate Training: An ESUT AEEP Group Study
title_short Determination of Face and Content Validity of Cadaveric Model for Holmium Anatomic Endoscopic Enucleation of the Prostate Training: An ESUT AEEP Group Study
title_sort determination of face and content validity of cadaveric model for holmium anatomic endoscopic enucleation of the prostate training: an esut aeep group study
topic Education
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8505198/
https://www.ncbi.nlm.nih.gov/pubmed/34667956
http://dx.doi.org/10.1016/j.euros.2021.07.005
work_keys_str_mv AT tunclutfi determinationoffaceandcontentvalidityofcadavericmodelforholmiumanatomicendoscopicenucleationoftheprostatetraininganesutaeepgroupstudy
AT bozzinigiorgio determinationoffaceandcontentvalidityofcadavericmodelforholmiumanatomicendoscopicenucleationoftheprostatetraininganesutaeepgroupstudy
AT scoffonecesaremarco determinationoffaceandcontentvalidityofcadavericmodelforholmiumanatomicendoscopicenucleationoftheprostatetraininganesutaeepgroupstudy
AT guvenselcuk determinationoffaceandcontentvalidityofcadavericmodelforholmiumanatomicendoscopicenucleationoftheprostatetraininganesutaeepgroupstudy
AT hermannthomas determinationoffaceandcontentvalidityofcadavericmodelforholmiumanatomicendoscopicenucleationoftheprostatetraininganesutaeepgroupstudy
AT porrecaangelo determinationoffaceandcontentvalidityofcadavericmodelforholmiumanatomicendoscopicenucleationoftheprostatetraininganesutaeepgroupstudy
AT misraivincent determinationoffaceandcontentvalidityofcadavericmodelforholmiumanatomicendoscopicenucleationoftheprostatetraininganesutaeepgroupstudy
AT ahyaisascha determinationoffaceandcontentvalidityofcadavericmodelforholmiumanatomicendoscopicenucleationoftheprostatetraininganesutaeepgroupstudy
AT zormurat determinationoffaceandcontentvalidityofcadavericmodelforholmiumanatomicendoscopicenucleationoftheprostatetraininganesutaeepgroupstudy
AT aksoyemin determinationoffaceandcontentvalidityofcadavericmodelforholmiumanatomicendoscopicenucleationoftheprostatetraininganesutaeepgroupstudy
AT gozenalis determinationoffaceandcontentvalidityofcadavericmodelforholmiumanatomicendoscopicenucleationoftheprostatetraininganesutaeepgroupstudy