Cargando…

COMPARISON OF METAL ARTEFACTS FOR DIFFERENT DUAL ENERGY CT TECHNIQUES

This study compares dual-energy computed tomography (DECT) images of a phantom including different material inserts and with additional lateral titanium or stainless steel inserts, simulating bilateral hip prostheses. Dual-source (DS) and fast kV-switching (FKS) DECT with/without metal artefact redu...

Descripción completa

Detalles Bibliográficos
Autores principales: Pettersson, E, Bäck, A, Thilander-Klang, A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8507444/
https://www.ncbi.nlm.nih.gov/pubmed/34345904
http://dx.doi.org/10.1093/rpd/ncab105
_version_ 1784581857019428864
author Pettersson, E
Bäck, A
Thilander-Klang, A
author_facet Pettersson, E
Bäck, A
Thilander-Klang, A
author_sort Pettersson, E
collection PubMed
description This study compares dual-energy computed tomography (DECT) images of a phantom including different material inserts and with additional lateral titanium or stainless steel inserts, simulating bilateral hip prostheses. Dual-source (DS) and fast kV-switching (FKS) DECT with/without metal artefact reduction (MAR) were compared with regards to virtually monoenergetic CT number accuracy and the depiction of different materials. Streak artefacts were observed between the metal inserts that were more severe with steel compared to titanium inserts. The artefact severity and CT number accuracy depended on the photon energy (keV) for both DECT techniques. While MAR generally increased the CT number accuracy and material depiction within the streak artefacts, it sometimes decreased the accuracy outside the streak artefacts for both DS and FKS. FKS depicted the metal inserts more accurately than DS with regards to both CT numbers and external diameter.
format Online
Article
Text
id pubmed-8507444
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-85074442021-10-13 COMPARISON OF METAL ARTEFACTS FOR DIFFERENT DUAL ENERGY CT TECHNIQUES Pettersson, E Bäck, A Thilander-Klang, A Radiat Prot Dosimetry Paper This study compares dual-energy computed tomography (DECT) images of a phantom including different material inserts and with additional lateral titanium or stainless steel inserts, simulating bilateral hip prostheses. Dual-source (DS) and fast kV-switching (FKS) DECT with/without metal artefact reduction (MAR) were compared with regards to virtually monoenergetic CT number accuracy and the depiction of different materials. Streak artefacts were observed between the metal inserts that were more severe with steel compared to titanium inserts. The artefact severity and CT number accuracy depended on the photon energy (keV) for both DECT techniques. While MAR generally increased the CT number accuracy and material depiction within the streak artefacts, it sometimes decreased the accuracy outside the streak artefacts for both DS and FKS. FKS depicted the metal inserts more accurately than DS with regards to both CT numbers and external diameter. Oxford University Press 2021-08-04 /pmc/articles/PMC8507444/ /pubmed/34345904 http://dx.doi.org/10.1093/rpd/ncab105 Text en © The Author(s) 2021. Published by Oxford University Press. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Paper
Pettersson, E
Bäck, A
Thilander-Klang, A
COMPARISON OF METAL ARTEFACTS FOR DIFFERENT DUAL ENERGY CT TECHNIQUES
title COMPARISON OF METAL ARTEFACTS FOR DIFFERENT DUAL ENERGY CT TECHNIQUES
title_full COMPARISON OF METAL ARTEFACTS FOR DIFFERENT DUAL ENERGY CT TECHNIQUES
title_fullStr COMPARISON OF METAL ARTEFACTS FOR DIFFERENT DUAL ENERGY CT TECHNIQUES
title_full_unstemmed COMPARISON OF METAL ARTEFACTS FOR DIFFERENT DUAL ENERGY CT TECHNIQUES
title_short COMPARISON OF METAL ARTEFACTS FOR DIFFERENT DUAL ENERGY CT TECHNIQUES
title_sort comparison of metal artefacts for different dual energy ct techniques
topic Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8507444/
https://www.ncbi.nlm.nih.gov/pubmed/34345904
http://dx.doi.org/10.1093/rpd/ncab105
work_keys_str_mv AT petterssone comparisonofmetalartefactsfordifferentdualenergycttechniques
AT backa comparisonofmetalartefactsfordifferentdualenergycttechniques
AT thilanderklanga comparisonofmetalartefactsfordifferentdualenergycttechniques