IMAGE QUALITY AND POTENTIAL DOSE REDUCTION USING ADVANCED MODELED ITERATIVE RECONSTRUCTION (ADMIRE) IN ABDOMINAL CT - A REVIEW
Traditional filtered back projection (FBP) reconstruction methods have served the computed tomography (CT) community well for over 40 years. With the increased use of CT during the last decades, efforts to minimise patient exposure, while maintaining sufficient or improved image quality, have led to...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8507455/ https://www.ncbi.nlm.nih.gov/pubmed/33778892 http://dx.doi.org/10.1093/rpd/ncab020 |
_version_ | 1784581859571662848 |
---|---|
author | Kataria, B Nilsson Althén, J Smedby, Ö Persson, A Sökjer, H Sandborg, M |
author_facet | Kataria, B Nilsson Althén, J Smedby, Ö Persson, A Sökjer, H Sandborg, M |
author_sort | Kataria, B |
collection | PubMed |
description | Traditional filtered back projection (FBP) reconstruction methods have served the computed tomography (CT) community well for over 40 years. With the increased use of CT during the last decades, efforts to minimise patient exposure, while maintaining sufficient or improved image quality, have led to the development of model-based iterative reconstruction (MBIR) algorithms from several vendors. The usefulness of the advanced modeled iterative reconstruction (ADMIRE) (Siemens Healthineers) MBIR in abdominal CT is reviewed and its noise suppression and/or dose reduction possibilities explored. Quantitative and qualitative methods with phantom and human subjects were used. Assessment of the quality of phantom images will not always correlate positively with those of patient images, particularly at the higher strength of the ADMIRE algorithm. With few exceptions, ADMIRE Strength 3 typically allows for substantial noise reduction compared to FBP and hence to significant (≈30%) patient dose reductions. The size of the dose reductions depends on the diagnostic task. |
format | Online Article Text |
id | pubmed-8507455 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-85074552021-10-13 IMAGE QUALITY AND POTENTIAL DOSE REDUCTION USING ADVANCED MODELED ITERATIVE RECONSTRUCTION (ADMIRE) IN ABDOMINAL CT - A REVIEW Kataria, B Nilsson Althén, J Smedby, Ö Persson, A Sökjer, H Sandborg, M Radiat Prot Dosimetry Paper Traditional filtered back projection (FBP) reconstruction methods have served the computed tomography (CT) community well for over 40 years. With the increased use of CT during the last decades, efforts to minimise patient exposure, while maintaining sufficient or improved image quality, have led to the development of model-based iterative reconstruction (MBIR) algorithms from several vendors. The usefulness of the advanced modeled iterative reconstruction (ADMIRE) (Siemens Healthineers) MBIR in abdominal CT is reviewed and its noise suppression and/or dose reduction possibilities explored. Quantitative and qualitative methods with phantom and human subjects were used. Assessment of the quality of phantom images will not always correlate positively with those of patient images, particularly at the higher strength of the ADMIRE algorithm. With few exceptions, ADMIRE Strength 3 typically allows for substantial noise reduction compared to FBP and hence to significant (≈30%) patient dose reductions. The size of the dose reductions depends on the diagnostic task. Oxford University Press 2021-03-29 /pmc/articles/PMC8507455/ /pubmed/33778892 http://dx.doi.org/10.1093/rpd/ncab020 Text en © The Author(s) 2021. Published by Oxford University Press. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Paper Kataria, B Nilsson Althén, J Smedby, Ö Persson, A Sökjer, H Sandborg, M IMAGE QUALITY AND POTENTIAL DOSE REDUCTION USING ADVANCED MODELED ITERATIVE RECONSTRUCTION (ADMIRE) IN ABDOMINAL CT - A REVIEW |
title | IMAGE QUALITY AND POTENTIAL DOSE REDUCTION USING ADVANCED MODELED ITERATIVE RECONSTRUCTION (ADMIRE) IN ABDOMINAL CT - A REVIEW |
title_full | IMAGE QUALITY AND POTENTIAL DOSE REDUCTION USING ADVANCED MODELED ITERATIVE RECONSTRUCTION (ADMIRE) IN ABDOMINAL CT - A REVIEW |
title_fullStr | IMAGE QUALITY AND POTENTIAL DOSE REDUCTION USING ADVANCED MODELED ITERATIVE RECONSTRUCTION (ADMIRE) IN ABDOMINAL CT - A REVIEW |
title_full_unstemmed | IMAGE QUALITY AND POTENTIAL DOSE REDUCTION USING ADVANCED MODELED ITERATIVE RECONSTRUCTION (ADMIRE) IN ABDOMINAL CT - A REVIEW |
title_short | IMAGE QUALITY AND POTENTIAL DOSE REDUCTION USING ADVANCED MODELED ITERATIVE RECONSTRUCTION (ADMIRE) IN ABDOMINAL CT - A REVIEW |
title_sort | image quality and potential dose reduction using advanced modeled iterative reconstruction (admire) in abdominal ct - a review |
topic | Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8507455/ https://www.ncbi.nlm.nih.gov/pubmed/33778892 http://dx.doi.org/10.1093/rpd/ncab020 |
work_keys_str_mv | AT katariab imagequalityandpotentialdosereductionusingadvancedmodelediterativereconstructionadmireinabdominalctareview AT nilssonalthenj imagequalityandpotentialdosereductionusingadvancedmodelediterativereconstructionadmireinabdominalctareview AT smedbyo imagequalityandpotentialdosereductionusingadvancedmodelediterativereconstructionadmireinabdominalctareview AT perssona imagequalityandpotentialdosereductionusingadvancedmodelediterativereconstructionadmireinabdominalctareview AT sokjerh imagequalityandpotentialdosereductionusingadvancedmodelediterativereconstructionadmireinabdominalctareview AT sandborgm imagequalityandpotentialdosereductionusingadvancedmodelediterativereconstructionadmireinabdominalctareview |