Cargando…
Use of Intraoral Scanners for Full Dental Arches: Could Different Strategies or Overlapping Software Affect Accuracy?
Objectives: The use of digital devices is strongly influencing the dental rehabilitation workflow both for single-crown rehabilitation and for full-arch prosthetic treatments. Methods: In this study, trueness was analyzed by overlapping the scan dataset made with Medit I-500 (by using two different...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8507837/ https://www.ncbi.nlm.nih.gov/pubmed/34639250 http://dx.doi.org/10.3390/ijerph18199946 |
_version_ | 1784581953543995392 |
---|---|
author | Stefanelli, Luigi Vito Franchina, Alessio Pranno, Andrea Pellegrino, Gerardo Ferri, Agnese Pranno, Nicola Di Carlo, Stefano De Angelis, Francesca |
author_facet | Stefanelli, Luigi Vito Franchina, Alessio Pranno, Andrea Pellegrino, Gerardo Ferri, Agnese Pranno, Nicola Di Carlo, Stefano De Angelis, Francesca |
author_sort | Stefanelli, Luigi Vito |
collection | PubMed |
description | Objectives: The use of digital devices is strongly influencing the dental rehabilitation workflow both for single-crown rehabilitation and for full-arch prosthetic treatments. Methods: In this study, trueness was analyzed by overlapping the scan dataset made with Medit I-500 (by using two different tips and two different scan strategies) with the scan dataset made with lab scanning, and the values of the (90°–10°)/2 method were reported. Precision was evaluated by using the same values of trueness coming from the intra-group overlapping (scan dataset made with an IOS overlapped and compared to each other). Moreover, two different software programs of overlapping were used to calculate accuracy values. Results: The mean difference of trueness was 26.61 ± 5.07 µm with the suggested strategy of intraoral scanning and using a new design of the tip, 37.99 ± 4.94 µm with the suggested strategy of intraoral scanning and using the old design of the tip, and 51.22 ± 6.57 µm with a new strategy of intraoral scanning and using the old design of the tip. The mean difference of precision was 23.57 ± 5.77 µm with the suggested strategy of intraoral scanning and using a new design of the tip, 38.34 ± 11.39 µm with the suggested strategy of intraoral scanning and using the old design of the tip, and 46.93 ± 7.15 µm with a new strategy of intraoral scanning and using the old design of the tip. No difference was found in the trueness and precision data extracted using the two different programs of superimposition Geomagic Control X and Medit Compare. Conclusions: The outcomes of this study showed that the latest version of I-Medit 500 with the use of a new tip seems to be promising in terms of accuracy when a full arch needs to be scanned. Moreover, Medit Compare, which is an application of Medit IOS software, can be used to calculate IOS accuracy. |
format | Online Article Text |
id | pubmed-8507837 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-85078372021-10-13 Use of Intraoral Scanners for Full Dental Arches: Could Different Strategies or Overlapping Software Affect Accuracy? Stefanelli, Luigi Vito Franchina, Alessio Pranno, Andrea Pellegrino, Gerardo Ferri, Agnese Pranno, Nicola Di Carlo, Stefano De Angelis, Francesca Int J Environ Res Public Health Article Objectives: The use of digital devices is strongly influencing the dental rehabilitation workflow both for single-crown rehabilitation and for full-arch prosthetic treatments. Methods: In this study, trueness was analyzed by overlapping the scan dataset made with Medit I-500 (by using two different tips and two different scan strategies) with the scan dataset made with lab scanning, and the values of the (90°–10°)/2 method were reported. Precision was evaluated by using the same values of trueness coming from the intra-group overlapping (scan dataset made with an IOS overlapped and compared to each other). Moreover, two different software programs of overlapping were used to calculate accuracy values. Results: The mean difference of trueness was 26.61 ± 5.07 µm with the suggested strategy of intraoral scanning and using a new design of the tip, 37.99 ± 4.94 µm with the suggested strategy of intraoral scanning and using the old design of the tip, and 51.22 ± 6.57 µm with a new strategy of intraoral scanning and using the old design of the tip. The mean difference of precision was 23.57 ± 5.77 µm with the suggested strategy of intraoral scanning and using a new design of the tip, 38.34 ± 11.39 µm with the suggested strategy of intraoral scanning and using the old design of the tip, and 46.93 ± 7.15 µm with a new strategy of intraoral scanning and using the old design of the tip. No difference was found in the trueness and precision data extracted using the two different programs of superimposition Geomagic Control X and Medit Compare. Conclusions: The outcomes of this study showed that the latest version of I-Medit 500 with the use of a new tip seems to be promising in terms of accuracy when a full arch needs to be scanned. Moreover, Medit Compare, which is an application of Medit IOS software, can be used to calculate IOS accuracy. MDPI 2021-09-22 /pmc/articles/PMC8507837/ /pubmed/34639250 http://dx.doi.org/10.3390/ijerph18199946 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Stefanelli, Luigi Vito Franchina, Alessio Pranno, Andrea Pellegrino, Gerardo Ferri, Agnese Pranno, Nicola Di Carlo, Stefano De Angelis, Francesca Use of Intraoral Scanners for Full Dental Arches: Could Different Strategies or Overlapping Software Affect Accuracy? |
title | Use of Intraoral Scanners for Full Dental Arches: Could Different Strategies or Overlapping Software Affect Accuracy? |
title_full | Use of Intraoral Scanners for Full Dental Arches: Could Different Strategies or Overlapping Software Affect Accuracy? |
title_fullStr | Use of Intraoral Scanners for Full Dental Arches: Could Different Strategies or Overlapping Software Affect Accuracy? |
title_full_unstemmed | Use of Intraoral Scanners for Full Dental Arches: Could Different Strategies or Overlapping Software Affect Accuracy? |
title_short | Use of Intraoral Scanners for Full Dental Arches: Could Different Strategies or Overlapping Software Affect Accuracy? |
title_sort | use of intraoral scanners for full dental arches: could different strategies or overlapping software affect accuracy? |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8507837/ https://www.ncbi.nlm.nih.gov/pubmed/34639250 http://dx.doi.org/10.3390/ijerph18199946 |
work_keys_str_mv | AT stefanelliluigivito useofintraoralscannersforfulldentalarchescoulddifferentstrategiesoroverlappingsoftwareaffectaccuracy AT franchinaalessio useofintraoralscannersforfulldentalarchescoulddifferentstrategiesoroverlappingsoftwareaffectaccuracy AT prannoandrea useofintraoralscannersforfulldentalarchescoulddifferentstrategiesoroverlappingsoftwareaffectaccuracy AT pellegrinogerardo useofintraoralscannersforfulldentalarchescoulddifferentstrategiesoroverlappingsoftwareaffectaccuracy AT ferriagnese useofintraoralscannersforfulldentalarchescoulddifferentstrategiesoroverlappingsoftwareaffectaccuracy AT prannonicola useofintraoralscannersforfulldentalarchescoulddifferentstrategiesoroverlappingsoftwareaffectaccuracy AT dicarlostefano useofintraoralscannersforfulldentalarchescoulddifferentstrategiesoroverlappingsoftwareaffectaccuracy AT deangelisfrancesca useofintraoralscannersforfulldentalarchescoulddifferentstrategiesoroverlappingsoftwareaffectaccuracy |