Cargando…
Patient–Ventilator Dyssynchrony in Critically Ill Patients
Patient–ventilator dyssynchrony is a mismatch between the patient’s respiratory efforts and mechanical ventilator delivery. Dyssynchrony can occur at any phase throughout the respiratory cycle. There are different types of dyssynchrony with different mechanisms and different potential management: tr...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8509510/ https://www.ncbi.nlm.nih.gov/pubmed/34640566 http://dx.doi.org/10.3390/jcm10194550 |
_version_ | 1784582359200301056 |
---|---|
author | De Oliveira, Bruno Aljaberi, Nahla Taha, Ahmed Abduljawad, Baraa Hamed, Fadi Rahman, Nadeem Mallat, Jihad |
author_facet | De Oliveira, Bruno Aljaberi, Nahla Taha, Ahmed Abduljawad, Baraa Hamed, Fadi Rahman, Nadeem Mallat, Jihad |
author_sort | De Oliveira, Bruno |
collection | PubMed |
description | Patient–ventilator dyssynchrony is a mismatch between the patient’s respiratory efforts and mechanical ventilator delivery. Dyssynchrony can occur at any phase throughout the respiratory cycle. There are different types of dyssynchrony with different mechanisms and different potential management: trigger dyssynchrony (ineffective efforts, autotriggering, and double triggering); flow dyssynchrony, which happens during the inspiratory phase; and cycling dyssynchrony (premature cycling and delayed cycling). Dyssynchrony has been associated with patient outcomes. Thus, it is important to recognize and address these dyssynchronies at the bedside. Patient–ventilator dyssynchrony can be detected by carefully scrutinizing the airway pressure–time and flow–time waveforms displayed on the ventilator screens along with assessing the patient’s comfort. Clinicians need to know how to depict these dyssynchronies at the bedside. This review aims to define the different types of dyssynchrony and then discuss the evidence for their relationship with patient outcomes and address their potential management. |
format | Online Article Text |
id | pubmed-8509510 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-85095102021-10-13 Patient–Ventilator Dyssynchrony in Critically Ill Patients De Oliveira, Bruno Aljaberi, Nahla Taha, Ahmed Abduljawad, Baraa Hamed, Fadi Rahman, Nadeem Mallat, Jihad J Clin Med Review Patient–ventilator dyssynchrony is a mismatch between the patient’s respiratory efforts and mechanical ventilator delivery. Dyssynchrony can occur at any phase throughout the respiratory cycle. There are different types of dyssynchrony with different mechanisms and different potential management: trigger dyssynchrony (ineffective efforts, autotriggering, and double triggering); flow dyssynchrony, which happens during the inspiratory phase; and cycling dyssynchrony (premature cycling and delayed cycling). Dyssynchrony has been associated with patient outcomes. Thus, it is important to recognize and address these dyssynchronies at the bedside. Patient–ventilator dyssynchrony can be detected by carefully scrutinizing the airway pressure–time and flow–time waveforms displayed on the ventilator screens along with assessing the patient’s comfort. Clinicians need to know how to depict these dyssynchronies at the bedside. This review aims to define the different types of dyssynchrony and then discuss the evidence for their relationship with patient outcomes and address their potential management. MDPI 2021-09-30 /pmc/articles/PMC8509510/ /pubmed/34640566 http://dx.doi.org/10.3390/jcm10194550 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Review De Oliveira, Bruno Aljaberi, Nahla Taha, Ahmed Abduljawad, Baraa Hamed, Fadi Rahman, Nadeem Mallat, Jihad Patient–Ventilator Dyssynchrony in Critically Ill Patients |
title | Patient–Ventilator Dyssynchrony in Critically Ill Patients |
title_full | Patient–Ventilator Dyssynchrony in Critically Ill Patients |
title_fullStr | Patient–Ventilator Dyssynchrony in Critically Ill Patients |
title_full_unstemmed | Patient–Ventilator Dyssynchrony in Critically Ill Patients |
title_short | Patient–Ventilator Dyssynchrony in Critically Ill Patients |
title_sort | patient–ventilator dyssynchrony in critically ill patients |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8509510/ https://www.ncbi.nlm.nih.gov/pubmed/34640566 http://dx.doi.org/10.3390/jcm10194550 |
work_keys_str_mv | AT deoliveirabruno patientventilatordyssynchronyincriticallyillpatients AT aljaberinahla patientventilatordyssynchronyincriticallyillpatients AT tahaahmed patientventilatordyssynchronyincriticallyillpatients AT abduljawadbaraa patientventilatordyssynchronyincriticallyillpatients AT hamedfadi patientventilatordyssynchronyincriticallyillpatients AT rahmannadeem patientventilatordyssynchronyincriticallyillpatients AT mallatjihad patientventilatordyssynchronyincriticallyillpatients |