Patient–Ventilator Dyssynchrony in Critically Ill Patients

Patient–ventilator dyssynchrony is a mismatch between the patient’s respiratory efforts and mechanical ventilator delivery. Dyssynchrony can occur at any phase throughout the respiratory cycle. There are different types of dyssynchrony with different mechanisms and different potential management: tr...

Descripción completa

Detalles Bibliográficos
Autores principales: De Oliveira, Bruno, Aljaberi, Nahla, Taha, Ahmed, Abduljawad, Baraa, Hamed, Fadi, Rahman, Nadeem, Mallat, Jihad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8509510/
https://www.ncbi.nlm.nih.gov/pubmed/34640566
http://dx.doi.org/10.3390/jcm10194550
_version_ 1784582359200301056
author De Oliveira, Bruno
Aljaberi, Nahla
Taha, Ahmed
Abduljawad, Baraa
Hamed, Fadi
Rahman, Nadeem
Mallat, Jihad
author_facet De Oliveira, Bruno
Aljaberi, Nahla
Taha, Ahmed
Abduljawad, Baraa
Hamed, Fadi
Rahman, Nadeem
Mallat, Jihad
author_sort De Oliveira, Bruno
collection PubMed
description Patient–ventilator dyssynchrony is a mismatch between the patient’s respiratory efforts and mechanical ventilator delivery. Dyssynchrony can occur at any phase throughout the respiratory cycle. There are different types of dyssynchrony with different mechanisms and different potential management: trigger dyssynchrony (ineffective efforts, autotriggering, and double triggering); flow dyssynchrony, which happens during the inspiratory phase; and cycling dyssynchrony (premature cycling and delayed cycling). Dyssynchrony has been associated with patient outcomes. Thus, it is important to recognize and address these dyssynchronies at the bedside. Patient–ventilator dyssynchrony can be detected by carefully scrutinizing the airway pressure–time and flow–time waveforms displayed on the ventilator screens along with assessing the patient’s comfort. Clinicians need to know how to depict these dyssynchronies at the bedside. This review aims to define the different types of dyssynchrony and then discuss the evidence for their relationship with patient outcomes and address their potential management.
format Online
Article
Text
id pubmed-8509510
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85095102021-10-13 Patient–Ventilator Dyssynchrony in Critically Ill Patients De Oliveira, Bruno Aljaberi, Nahla Taha, Ahmed Abduljawad, Baraa Hamed, Fadi Rahman, Nadeem Mallat, Jihad J Clin Med Review Patient–ventilator dyssynchrony is a mismatch between the patient’s respiratory efforts and mechanical ventilator delivery. Dyssynchrony can occur at any phase throughout the respiratory cycle. There are different types of dyssynchrony with different mechanisms and different potential management: trigger dyssynchrony (ineffective efforts, autotriggering, and double triggering); flow dyssynchrony, which happens during the inspiratory phase; and cycling dyssynchrony (premature cycling and delayed cycling). Dyssynchrony has been associated with patient outcomes. Thus, it is important to recognize and address these dyssynchronies at the bedside. Patient–ventilator dyssynchrony can be detected by carefully scrutinizing the airway pressure–time and flow–time waveforms displayed on the ventilator screens along with assessing the patient’s comfort. Clinicians need to know how to depict these dyssynchronies at the bedside. This review aims to define the different types of dyssynchrony and then discuss the evidence for their relationship with patient outcomes and address their potential management. MDPI 2021-09-30 /pmc/articles/PMC8509510/ /pubmed/34640566 http://dx.doi.org/10.3390/jcm10194550 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
De Oliveira, Bruno
Aljaberi, Nahla
Taha, Ahmed
Abduljawad, Baraa
Hamed, Fadi
Rahman, Nadeem
Mallat, Jihad
Patient–Ventilator Dyssynchrony in Critically Ill Patients
title Patient–Ventilator Dyssynchrony in Critically Ill Patients
title_full Patient–Ventilator Dyssynchrony in Critically Ill Patients
title_fullStr Patient–Ventilator Dyssynchrony in Critically Ill Patients
title_full_unstemmed Patient–Ventilator Dyssynchrony in Critically Ill Patients
title_short Patient–Ventilator Dyssynchrony in Critically Ill Patients
title_sort patient–ventilator dyssynchrony in critically ill patients
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8509510/
https://www.ncbi.nlm.nih.gov/pubmed/34640566
http://dx.doi.org/10.3390/jcm10194550
work_keys_str_mv AT deoliveirabruno patientventilatordyssynchronyincriticallyillpatients
AT aljaberinahla patientventilatordyssynchronyincriticallyillpatients
AT tahaahmed patientventilatordyssynchronyincriticallyillpatients
AT abduljawadbaraa patientventilatordyssynchronyincriticallyillpatients
AT hamedfadi patientventilatordyssynchronyincriticallyillpatients
AT rahmannadeem patientventilatordyssynchronyincriticallyillpatients
AT mallatjihad patientventilatordyssynchronyincriticallyillpatients