Cargando…

Cochlear Implantation in Elderly Patients with Residual Hearing

This retrospective study aimed to investigate the range of hearing levels in a cochlear implant (CI) elderly population receiving electric-acoustic-stimulation (EAS) or electric-stimulation (ES) alone. The investigation evaluates the degree of hearing preservation (HP) and the speech comprehension r...

Descripción completa

Detalles Bibliográficos
Autores principales: Matin, Farnaz, Artukarslan, Eralp-Niyazi, Illg, Angelika, Lesinski-Schiedat, Anke, Lenarz, Thomas, Suhling, Marie Charlot
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8509733/
https://www.ncbi.nlm.nih.gov/pubmed/34640325
http://dx.doi.org/10.3390/jcm10194305
_version_ 1784582414400487424
author Matin, Farnaz
Artukarslan, Eralp-Niyazi
Illg, Angelika
Lesinski-Schiedat, Anke
Lenarz, Thomas
Suhling, Marie Charlot
author_facet Matin, Farnaz
Artukarslan, Eralp-Niyazi
Illg, Angelika
Lesinski-Schiedat, Anke
Lenarz, Thomas
Suhling, Marie Charlot
author_sort Matin, Farnaz
collection PubMed
description This retrospective study aimed to investigate the range of hearing levels in a cochlear implant (CI) elderly population receiving electric-acoustic-stimulation (EAS) or electric-stimulation (ES) alone. The investigation evaluates the degree of hearing preservation (HP) and the speech comprehension resulting from EAS or ES-only to identify audiometric factors that predict adequate EAS and ES use. We analyzed the pure tone audiometry and speech perception in quiet and noise preoperatively and 12-months after activation of 89 elderly adults (age of 65 years old or older), yielding in total 97 CIs. Thirty-two (33.1%) patients were potential EAS candidates preoperatively, of which 18 patients used EAS at the time of first fitting and the other 14 patients continued to use their residual hearing for EAS at 12-months. Post-treatment, patients with EAS system and ES-only users’ with longer electrodes showed better results in monosyllable word scores in quiet than ES-only users with shorter electrodes. A similar trend was revealed for the speech recognition in noise. Patients with an EAS system benefit from maintaining their natural residual hearing. Nevertheless, strict preoperative patient selection is warranted particularly in elderly patients, in whom the hearing thresholds for EAS indication differ slightly from that in younger adults.
format Online
Article
Text
id pubmed-8509733
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85097332021-10-13 Cochlear Implantation in Elderly Patients with Residual Hearing Matin, Farnaz Artukarslan, Eralp-Niyazi Illg, Angelika Lesinski-Schiedat, Anke Lenarz, Thomas Suhling, Marie Charlot J Clin Med Article This retrospective study aimed to investigate the range of hearing levels in a cochlear implant (CI) elderly population receiving electric-acoustic-stimulation (EAS) or electric-stimulation (ES) alone. The investigation evaluates the degree of hearing preservation (HP) and the speech comprehension resulting from EAS or ES-only to identify audiometric factors that predict adequate EAS and ES use. We analyzed the pure tone audiometry and speech perception in quiet and noise preoperatively and 12-months after activation of 89 elderly adults (age of 65 years old or older), yielding in total 97 CIs. Thirty-two (33.1%) patients were potential EAS candidates preoperatively, of which 18 patients used EAS at the time of first fitting and the other 14 patients continued to use their residual hearing for EAS at 12-months. Post-treatment, patients with EAS system and ES-only users’ with longer electrodes showed better results in monosyllable word scores in quiet than ES-only users with shorter electrodes. A similar trend was revealed for the speech recognition in noise. Patients with an EAS system benefit from maintaining their natural residual hearing. Nevertheless, strict preoperative patient selection is warranted particularly in elderly patients, in whom the hearing thresholds for EAS indication differ slightly from that in younger adults. MDPI 2021-09-22 /pmc/articles/PMC8509733/ /pubmed/34640325 http://dx.doi.org/10.3390/jcm10194305 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Matin, Farnaz
Artukarslan, Eralp-Niyazi
Illg, Angelika
Lesinski-Schiedat, Anke
Lenarz, Thomas
Suhling, Marie Charlot
Cochlear Implantation in Elderly Patients with Residual Hearing
title Cochlear Implantation in Elderly Patients with Residual Hearing
title_full Cochlear Implantation in Elderly Patients with Residual Hearing
title_fullStr Cochlear Implantation in Elderly Patients with Residual Hearing
title_full_unstemmed Cochlear Implantation in Elderly Patients with Residual Hearing
title_short Cochlear Implantation in Elderly Patients with Residual Hearing
title_sort cochlear implantation in elderly patients with residual hearing
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8509733/
https://www.ncbi.nlm.nih.gov/pubmed/34640325
http://dx.doi.org/10.3390/jcm10194305
work_keys_str_mv AT matinfarnaz cochlearimplantationinelderlypatientswithresidualhearing
AT artukarslaneralpniyazi cochlearimplantationinelderlypatientswithresidualhearing
AT illgangelika cochlearimplantationinelderlypatientswithresidualhearing
AT lesinskischiedatanke cochlearimplantationinelderlypatientswithresidualhearing
AT lenarzthomas cochlearimplantationinelderlypatientswithresidualhearing
AT suhlingmariecharlot cochlearimplantationinelderlypatientswithresidualhearing