Cargando…
Vertical and Orovestibular Forces Generated by Beta-Titanium and Stainless-Steel Rectangular Wires in Labial and Fully Customized Lingual Bracket Systems
This study aimed to investigate the force values exerted from rectangular wires when combined with conventional labial and fully customized lingual appliances under predefined, idealized activation. Fully customized lingual brackets of two brands Incognito™ (3M Unitek, Monrovia, CA, USA) and WIN (DW...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8510413/ https://www.ncbi.nlm.nih.gov/pubmed/34640028 http://dx.doi.org/10.3390/ma14195632 |
_version_ | 1784582566168231936 |
---|---|
author | Kyprianou, Chrystalla Chatzigianni, Athina Daratsianos, Nikolaos Bourauel, Christoph |
author_facet | Kyprianou, Chrystalla Chatzigianni, Athina Daratsianos, Nikolaos Bourauel, Christoph |
author_sort | Kyprianou, Chrystalla |
collection | PubMed |
description | This study aimed to investigate the force values exerted from rectangular wires when combined with conventional labial and fully customized lingual appliances under predefined, idealized activation. Fully customized lingual brackets of two brands Incognito™ (3M Unitek, Monrovia, CA, USA) and WIN (DW Lingual Systems, Bad Essen, Germany) and labial brackets of another brand, discovery(®) MIM and discovery(®) smart systems (Dentaurum, Ispringen, Germany), were chosen. Stainless-steel and beta-titanium wires of 0.018” × 0.025” were examined. For Incognito(TM), 0.0182” × 0.025” beta-titanium wires were tested. Intrusion/extrusion and orovestibular movements were performed in a range of 0.2 mm, and the forces were recorded for each 0.1 mm of the movement. Mean values and standard deviations were calculated for all measurements, and ANOVA was performed for statistical analysis. Slight differences were observed between the forces generated from beta-titanium and stainless-steel wires. The same wire generated in some cases 5–53% higher forces with the lingual appliance due to the vertical orientation of the long walls during intrusion/extrusion and increased wire stiffness at the anterior region. Beta-titanium and stainless-steel 0.018” × 0.025” wires can generate similar force values during the final stages of the orthodontic therapy; thus, possibly only one of the two alloys could be used in each orthodontic wire sequence. |
format | Online Article Text |
id | pubmed-8510413 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-85104132021-10-13 Vertical and Orovestibular Forces Generated by Beta-Titanium and Stainless-Steel Rectangular Wires in Labial and Fully Customized Lingual Bracket Systems Kyprianou, Chrystalla Chatzigianni, Athina Daratsianos, Nikolaos Bourauel, Christoph Materials (Basel) Article This study aimed to investigate the force values exerted from rectangular wires when combined with conventional labial and fully customized lingual appliances under predefined, idealized activation. Fully customized lingual brackets of two brands Incognito™ (3M Unitek, Monrovia, CA, USA) and WIN (DW Lingual Systems, Bad Essen, Germany) and labial brackets of another brand, discovery(®) MIM and discovery(®) smart systems (Dentaurum, Ispringen, Germany), were chosen. Stainless-steel and beta-titanium wires of 0.018” × 0.025” were examined. For Incognito(TM), 0.0182” × 0.025” beta-titanium wires were tested. Intrusion/extrusion and orovestibular movements were performed in a range of 0.2 mm, and the forces were recorded for each 0.1 mm of the movement. Mean values and standard deviations were calculated for all measurements, and ANOVA was performed for statistical analysis. Slight differences were observed between the forces generated from beta-titanium and stainless-steel wires. The same wire generated in some cases 5–53% higher forces with the lingual appliance due to the vertical orientation of the long walls during intrusion/extrusion and increased wire stiffness at the anterior region. Beta-titanium and stainless-steel 0.018” × 0.025” wires can generate similar force values during the final stages of the orthodontic therapy; thus, possibly only one of the two alloys could be used in each orthodontic wire sequence. MDPI 2021-09-28 /pmc/articles/PMC8510413/ /pubmed/34640028 http://dx.doi.org/10.3390/ma14195632 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kyprianou, Chrystalla Chatzigianni, Athina Daratsianos, Nikolaos Bourauel, Christoph Vertical and Orovestibular Forces Generated by Beta-Titanium and Stainless-Steel Rectangular Wires in Labial and Fully Customized Lingual Bracket Systems |
title | Vertical and Orovestibular Forces Generated by Beta-Titanium and Stainless-Steel Rectangular Wires in Labial and Fully Customized Lingual Bracket Systems |
title_full | Vertical and Orovestibular Forces Generated by Beta-Titanium and Stainless-Steel Rectangular Wires in Labial and Fully Customized Lingual Bracket Systems |
title_fullStr | Vertical and Orovestibular Forces Generated by Beta-Titanium and Stainless-Steel Rectangular Wires in Labial and Fully Customized Lingual Bracket Systems |
title_full_unstemmed | Vertical and Orovestibular Forces Generated by Beta-Titanium and Stainless-Steel Rectangular Wires in Labial and Fully Customized Lingual Bracket Systems |
title_short | Vertical and Orovestibular Forces Generated by Beta-Titanium and Stainless-Steel Rectangular Wires in Labial and Fully Customized Lingual Bracket Systems |
title_sort | vertical and orovestibular forces generated by beta-titanium and stainless-steel rectangular wires in labial and fully customized lingual bracket systems |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8510413/ https://www.ncbi.nlm.nih.gov/pubmed/34640028 http://dx.doi.org/10.3390/ma14195632 |
work_keys_str_mv | AT kyprianouchrystalla verticalandorovestibularforcesgeneratedbybetatitaniumandstainlesssteelrectangularwiresinlabialandfullycustomizedlingualbracketsystems AT chatzigianniathina verticalandorovestibularforcesgeneratedbybetatitaniumandstainlesssteelrectangularwiresinlabialandfullycustomizedlingualbracketsystems AT daratsianosnikolaos verticalandorovestibularforcesgeneratedbybetatitaniumandstainlesssteelrectangularwiresinlabialandfullycustomizedlingualbracketsystems AT bourauelchristoph verticalandorovestibularforcesgeneratedbybetatitaniumandstainlesssteelrectangularwiresinlabialandfullycustomizedlingualbracketsystems |