Vertical and Orovestibular Forces Generated by Beta-Titanium and Stainless-Steel Rectangular Wires in Labial and Fully Customized Lingual Bracket Systems

This study aimed to investigate the force values exerted from rectangular wires when combined with conventional labial and fully customized lingual appliances under predefined, idealized activation. Fully customized lingual brackets of two brands Incognito™ (3M Unitek, Monrovia, CA, USA) and WIN (DW...

Descripción completa

Detalles Bibliográficos
Autores principales: Kyprianou, Chrystalla, Chatzigianni, Athina, Daratsianos, Nikolaos, Bourauel, Christoph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8510413/
https://www.ncbi.nlm.nih.gov/pubmed/34640028
http://dx.doi.org/10.3390/ma14195632
_version_ 1784582566168231936
author Kyprianou, Chrystalla
Chatzigianni, Athina
Daratsianos, Nikolaos
Bourauel, Christoph
author_facet Kyprianou, Chrystalla
Chatzigianni, Athina
Daratsianos, Nikolaos
Bourauel, Christoph
author_sort Kyprianou, Chrystalla
collection PubMed
description This study aimed to investigate the force values exerted from rectangular wires when combined with conventional labial and fully customized lingual appliances under predefined, idealized activation. Fully customized lingual brackets of two brands Incognito™ (3M Unitek, Monrovia, CA, USA) and WIN (DW Lingual Systems, Bad Essen, Germany) and labial brackets of another brand, discovery(®) MIM and discovery(®) smart systems (Dentaurum, Ispringen, Germany), were chosen. Stainless-steel and beta-titanium wires of 0.018” × 0.025” were examined. For Incognito(TM), 0.0182” × 0.025” beta-titanium wires were tested. Intrusion/extrusion and orovestibular movements were performed in a range of 0.2 mm, and the forces were recorded for each 0.1 mm of the movement. Mean values and standard deviations were calculated for all measurements, and ANOVA was performed for statistical analysis. Slight differences were observed between the forces generated from beta-titanium and stainless-steel wires. The same wire generated in some cases 5–53% higher forces with the lingual appliance due to the vertical orientation of the long walls during intrusion/extrusion and increased wire stiffness at the anterior region. Beta-titanium and stainless-steel 0.018” × 0.025” wires can generate similar force values during the final stages of the orthodontic therapy; thus, possibly only one of the two alloys could be used in each orthodontic wire sequence.
format Online
Article
Text
id pubmed-8510413
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85104132021-10-13 Vertical and Orovestibular Forces Generated by Beta-Titanium and Stainless-Steel Rectangular Wires in Labial and Fully Customized Lingual Bracket Systems Kyprianou, Chrystalla Chatzigianni, Athina Daratsianos, Nikolaos Bourauel, Christoph Materials (Basel) Article This study aimed to investigate the force values exerted from rectangular wires when combined with conventional labial and fully customized lingual appliances under predefined, idealized activation. Fully customized lingual brackets of two brands Incognito™ (3M Unitek, Monrovia, CA, USA) and WIN (DW Lingual Systems, Bad Essen, Germany) and labial brackets of another brand, discovery(®) MIM and discovery(®) smart systems (Dentaurum, Ispringen, Germany), were chosen. Stainless-steel and beta-titanium wires of 0.018” × 0.025” were examined. For Incognito(TM), 0.0182” × 0.025” beta-titanium wires were tested. Intrusion/extrusion and orovestibular movements were performed in a range of 0.2 mm, and the forces were recorded for each 0.1 mm of the movement. Mean values and standard deviations were calculated for all measurements, and ANOVA was performed for statistical analysis. Slight differences were observed between the forces generated from beta-titanium and stainless-steel wires. The same wire generated in some cases 5–53% higher forces with the lingual appliance due to the vertical orientation of the long walls during intrusion/extrusion and increased wire stiffness at the anterior region. Beta-titanium and stainless-steel 0.018” × 0.025” wires can generate similar force values during the final stages of the orthodontic therapy; thus, possibly only one of the two alloys could be used in each orthodontic wire sequence. MDPI 2021-09-28 /pmc/articles/PMC8510413/ /pubmed/34640028 http://dx.doi.org/10.3390/ma14195632 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kyprianou, Chrystalla
Chatzigianni, Athina
Daratsianos, Nikolaos
Bourauel, Christoph
Vertical and Orovestibular Forces Generated by Beta-Titanium and Stainless-Steel Rectangular Wires in Labial and Fully Customized Lingual Bracket Systems
title Vertical and Orovestibular Forces Generated by Beta-Titanium and Stainless-Steel Rectangular Wires in Labial and Fully Customized Lingual Bracket Systems
title_full Vertical and Orovestibular Forces Generated by Beta-Titanium and Stainless-Steel Rectangular Wires in Labial and Fully Customized Lingual Bracket Systems
title_fullStr Vertical and Orovestibular Forces Generated by Beta-Titanium and Stainless-Steel Rectangular Wires in Labial and Fully Customized Lingual Bracket Systems
title_full_unstemmed Vertical and Orovestibular Forces Generated by Beta-Titanium and Stainless-Steel Rectangular Wires in Labial and Fully Customized Lingual Bracket Systems
title_short Vertical and Orovestibular Forces Generated by Beta-Titanium and Stainless-Steel Rectangular Wires in Labial and Fully Customized Lingual Bracket Systems
title_sort vertical and orovestibular forces generated by beta-titanium and stainless-steel rectangular wires in labial and fully customized lingual bracket systems
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8510413/
https://www.ncbi.nlm.nih.gov/pubmed/34640028
http://dx.doi.org/10.3390/ma14195632
work_keys_str_mv AT kyprianouchrystalla verticalandorovestibularforcesgeneratedbybetatitaniumandstainlesssteelrectangularwiresinlabialandfullycustomizedlingualbracketsystems
AT chatzigianniathina verticalandorovestibularforcesgeneratedbybetatitaniumandstainlesssteelrectangularwiresinlabialandfullycustomizedlingualbracketsystems
AT daratsianosnikolaos verticalandorovestibularforcesgeneratedbybetatitaniumandstainlesssteelrectangularwiresinlabialandfullycustomizedlingualbracketsystems
AT bourauelchristoph verticalandorovestibularforcesgeneratedbybetatitaniumandstainlesssteelrectangularwiresinlabialandfullycustomizedlingualbracketsystems