4D Electromagnetic Navigation Bronchoscopy for the Sampling of Pulmonary Lesions: First European Real-Life Experience
PURPOSE: The use of Electromagnetic navigation bronchoscopy (ENB) for the diagnosis of pulmonary peripheral lesions is still debated due to its variable diagnostic yield; a new 4D ENB system, acquiring inspiratory and expiratory computed tomography (CT) scans, overcomes respiratory motion and uses t...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8510943/ https://www.ncbi.nlm.nih.gov/pubmed/34562105 http://dx.doi.org/10.1007/s00408-021-00477-z |
_version_ | 1784582681400442880 |
---|---|
author | Patrucco, Filippo Daverio, Matteo Airoldi, Chiara Falaschi, Zeno Longo, Vittorio Gavelli, Francesco Boldorini, Renzo Luciano Balbo, Piero Emilio |
author_facet | Patrucco, Filippo Daverio, Matteo Airoldi, Chiara Falaschi, Zeno Longo, Vittorio Gavelli, Francesco Boldorini, Renzo Luciano Balbo, Piero Emilio |
author_sort | Patrucco, Filippo |
collection | PubMed |
description | PURPOSE: The use of Electromagnetic navigation bronchoscopy (ENB) for the diagnosis of pulmonary peripheral lesions is still debated due to its variable diagnostic yield; a new 4D ENB system, acquiring inspiratory and expiratory computed tomography (CT) scans, overcomes respiratory motion and uses tracked sampling instruments, reaching higher diagnostic yields. We aimed at evaluating diagnostic yield and accuracy of a 4D ENB system in sampling pulmonary lesions and at describing their influencing factors. METHODS: We conducted a three-year retrospective observational study including all patients with pulmonary lesions who underwent 4D ENB with diagnostic purposes; all the factors potentially influencing diagnosis were recorded. RESULTS: 103 ENB procedures were included; diagnostic yield and accuracy were, respectively, 55.3% and 66.3%. We reported a navigation success rate of 80.6% and a diagnosis with ENB was achieved in 68.3% of cases; sensitivity for malignancy was 61.8%. The majority of lesions had a bronchus sign on CT, but only the size of lesions influenced ENB diagnosis (p < 0.05). Transbronchial needle aspiration biopsy was the most used tool (93.2% of times) with the higher diagnostic rate (70.2%). We reported only one case of pneumothorax. CONCLUSION: The diagnostic performance of a 4D ENB system is lower than other previous navigation systems used in research settings. Several factors still influence the reachability of the lesion and therefore diagnostic yield. Patient selection, as well as the multimodality approach of the lesion, is strongly recommended to obtain higher diagnostic yield and accuracy, with a low rate of complications. |
format | Online Article Text |
id | pubmed-8510943 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-85109432021-10-27 4D Electromagnetic Navigation Bronchoscopy for the Sampling of Pulmonary Lesions: First European Real-Life Experience Patrucco, Filippo Daverio, Matteo Airoldi, Chiara Falaschi, Zeno Longo, Vittorio Gavelli, Francesco Boldorini, Renzo Luciano Balbo, Piero Emilio Lung Interventional Pulmonology PURPOSE: The use of Electromagnetic navigation bronchoscopy (ENB) for the diagnosis of pulmonary peripheral lesions is still debated due to its variable diagnostic yield; a new 4D ENB system, acquiring inspiratory and expiratory computed tomography (CT) scans, overcomes respiratory motion and uses tracked sampling instruments, reaching higher diagnostic yields. We aimed at evaluating diagnostic yield and accuracy of a 4D ENB system in sampling pulmonary lesions and at describing their influencing factors. METHODS: We conducted a three-year retrospective observational study including all patients with pulmonary lesions who underwent 4D ENB with diagnostic purposes; all the factors potentially influencing diagnosis were recorded. RESULTS: 103 ENB procedures were included; diagnostic yield and accuracy were, respectively, 55.3% and 66.3%. We reported a navigation success rate of 80.6% and a diagnosis with ENB was achieved in 68.3% of cases; sensitivity for malignancy was 61.8%. The majority of lesions had a bronchus sign on CT, but only the size of lesions influenced ENB diagnosis (p < 0.05). Transbronchial needle aspiration biopsy was the most used tool (93.2% of times) with the higher diagnostic rate (70.2%). We reported only one case of pneumothorax. CONCLUSION: The diagnostic performance of a 4D ENB system is lower than other previous navigation systems used in research settings. Several factors still influence the reachability of the lesion and therefore diagnostic yield. Patient selection, as well as the multimodality approach of the lesion, is strongly recommended to obtain higher diagnostic yield and accuracy, with a low rate of complications. Springer US 2021-09-25 2021 /pmc/articles/PMC8510943/ /pubmed/34562105 http://dx.doi.org/10.1007/s00408-021-00477-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Interventional Pulmonology Patrucco, Filippo Daverio, Matteo Airoldi, Chiara Falaschi, Zeno Longo, Vittorio Gavelli, Francesco Boldorini, Renzo Luciano Balbo, Piero Emilio 4D Electromagnetic Navigation Bronchoscopy for the Sampling of Pulmonary Lesions: First European Real-Life Experience |
title | 4D Electromagnetic Navigation Bronchoscopy for the Sampling of Pulmonary Lesions: First European Real-Life Experience |
title_full | 4D Electromagnetic Navigation Bronchoscopy for the Sampling of Pulmonary Lesions: First European Real-Life Experience |
title_fullStr | 4D Electromagnetic Navigation Bronchoscopy for the Sampling of Pulmonary Lesions: First European Real-Life Experience |
title_full_unstemmed | 4D Electromagnetic Navigation Bronchoscopy for the Sampling of Pulmonary Lesions: First European Real-Life Experience |
title_short | 4D Electromagnetic Navigation Bronchoscopy for the Sampling of Pulmonary Lesions: First European Real-Life Experience |
title_sort | 4d electromagnetic navigation bronchoscopy for the sampling of pulmonary lesions: first european real-life experience |
topic | Interventional Pulmonology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8510943/ https://www.ncbi.nlm.nih.gov/pubmed/34562105 http://dx.doi.org/10.1007/s00408-021-00477-z |
work_keys_str_mv | AT patruccofilippo 4delectromagneticnavigationbronchoscopyforthesamplingofpulmonarylesionsfirsteuropeanreallifeexperience AT daveriomatteo 4delectromagneticnavigationbronchoscopyforthesamplingofpulmonarylesionsfirsteuropeanreallifeexperience AT airoldichiara 4delectromagneticnavigationbronchoscopyforthesamplingofpulmonarylesionsfirsteuropeanreallifeexperience AT falaschizeno 4delectromagneticnavigationbronchoscopyforthesamplingofpulmonarylesionsfirsteuropeanreallifeexperience AT longovittorio 4delectromagneticnavigationbronchoscopyforthesamplingofpulmonarylesionsfirsteuropeanreallifeexperience AT gavellifrancesco 4delectromagneticnavigationbronchoscopyforthesamplingofpulmonarylesionsfirsteuropeanreallifeexperience AT boldorinirenzoluciano 4delectromagneticnavigationbronchoscopyforthesamplingofpulmonarylesionsfirsteuropeanreallifeexperience AT balbopieroemilio 4delectromagneticnavigationbronchoscopyforthesamplingofpulmonarylesionsfirsteuropeanreallifeexperience |