Cargando…

Solid-Contact Ion-Selective Electrodes for Histamine Determination

Solid-contact ion-selective electrodes for histamine (HA) determination were fabricated and studied. Gold wire (0.5 mm diameter) was coated with poly(3,4-ethlenedioxythiophene) doped with poly(styrenesulfonate) (PEDOT:PSS) as a solid conductive layer. The polyvinyl chloride matrix embedded with 5,10...

Descripción completa

Detalles Bibliográficos
Autores principales: Ma, Siyuan, Wang, You, Zhang, Wei, Wang, Ye, Li, Guang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512055/
https://www.ncbi.nlm.nih.gov/pubmed/34640978
http://dx.doi.org/10.3390/s21196658
_version_ 1784582898262736896
author Ma, Siyuan
Wang, You
Zhang, Wei
Wang, Ye
Li, Guang
author_facet Ma, Siyuan
Wang, You
Zhang, Wei
Wang, Ye
Li, Guang
author_sort Ma, Siyuan
collection PubMed
description Solid-contact ion-selective electrodes for histamine (HA) determination were fabricated and studied. Gold wire (0.5 mm diameter) was coated with poly(3,4-ethlenedioxythiophene) doped with poly(styrenesulfonate) (PEDOT:PSS) as a solid conductive layer. The polyvinyl chloride matrix embedded with 5,10,15,20-tetraphenyl(porphyrinato)iron(iii) chloride as an ionophore, 2-nitrophenyloctyl ether as a plasticizer and potassium tetrakis(p-chlorophenyl) borate as an ion exchanger was used to cover the PEDOT:PSS layer as a selective membrane. The characteristics of the HA electrodes were also investigated. The detection limit of 8.58 × 10(−6) M, the fast response time of less than 5 s, the good reproducibility, the long-term stability and the selectivity in the presence of common interferences in biological fluids were satisfactory. The electrode also performed stably in the pH range of 7–8 and the temperature range of 35–41 °C. Additionally, the recovery rate of 99.7% in artificial cerebrospinal fluid showed the potential for the electrode to be used in biological applications.
format Online
Article
Text
id pubmed-8512055
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85120552021-10-14 Solid-Contact Ion-Selective Electrodes for Histamine Determination Ma, Siyuan Wang, You Zhang, Wei Wang, Ye Li, Guang Sensors (Basel) Communication Solid-contact ion-selective electrodes for histamine (HA) determination were fabricated and studied. Gold wire (0.5 mm diameter) was coated with poly(3,4-ethlenedioxythiophene) doped with poly(styrenesulfonate) (PEDOT:PSS) as a solid conductive layer. The polyvinyl chloride matrix embedded with 5,10,15,20-tetraphenyl(porphyrinato)iron(iii) chloride as an ionophore, 2-nitrophenyloctyl ether as a plasticizer and potassium tetrakis(p-chlorophenyl) borate as an ion exchanger was used to cover the PEDOT:PSS layer as a selective membrane. The characteristics of the HA electrodes were also investigated. The detection limit of 8.58 × 10(−6) M, the fast response time of less than 5 s, the good reproducibility, the long-term stability and the selectivity in the presence of common interferences in biological fluids were satisfactory. The electrode also performed stably in the pH range of 7–8 and the temperature range of 35–41 °C. Additionally, the recovery rate of 99.7% in artificial cerebrospinal fluid showed the potential for the electrode to be used in biological applications. MDPI 2021-10-07 /pmc/articles/PMC8512055/ /pubmed/34640978 http://dx.doi.org/10.3390/s21196658 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Ma, Siyuan
Wang, You
Zhang, Wei
Wang, Ye
Li, Guang
Solid-Contact Ion-Selective Electrodes for Histamine Determination
title Solid-Contact Ion-Selective Electrodes for Histamine Determination
title_full Solid-Contact Ion-Selective Electrodes for Histamine Determination
title_fullStr Solid-Contact Ion-Selective Electrodes for Histamine Determination
title_full_unstemmed Solid-Contact Ion-Selective Electrodes for Histamine Determination
title_short Solid-Contact Ion-Selective Electrodes for Histamine Determination
title_sort solid-contact ion-selective electrodes for histamine determination
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512055/
https://www.ncbi.nlm.nih.gov/pubmed/34640978
http://dx.doi.org/10.3390/s21196658
work_keys_str_mv AT masiyuan solidcontactionselectiveelectrodesforhistaminedetermination
AT wangyou solidcontactionselectiveelectrodesforhistaminedetermination
AT zhangwei solidcontactionselectiveelectrodesforhistaminedetermination
AT wangye solidcontactionselectiveelectrodesforhistaminedetermination
AT liguang solidcontactionselectiveelectrodesforhistaminedetermination