Cargando…
Sensorless Adaptive Voltage Control for Classical DC-DC Converters Feeding Unknown Loads: A Generalized PI Passivity-Based Approach
The problem of voltage regulation in unknown constant resistive loads is addressed in this paper from the nonlinear control point of view for second-order DC-DC converters. The converters’ topologies analyzed are: (i) buck converter, (ii) boost converter, (iii) buck-boost converter, and (iv) non-inv...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512427/ https://www.ncbi.nlm.nih.gov/pubmed/34640687 http://dx.doi.org/10.3390/s21196367 |
_version_ | 1784582988318638080 |
---|---|
author | Gil-González, Walter Montoya, Oscar Danilo Restrepo, Carlos Hernández, Jesus C. |
author_facet | Gil-González, Walter Montoya, Oscar Danilo Restrepo, Carlos Hernández, Jesus C. |
author_sort | Gil-González, Walter |
collection | PubMed |
description | The problem of voltage regulation in unknown constant resistive loads is addressed in this paper from the nonlinear control point of view for second-order DC-DC converters. The converters’ topologies analyzed are: (i) buck converter, (ii) boost converter, (iii) buck-boost converter, and (iv) non-inverting buck-boost converter. The averaging modeling method is used to model these converters, representing all these converter topologies with a generalized port-Controlled Hamiltonian (PCH) representation. The PCH representation shows that the second-order DC-DC converters exhibit a general bilinear structure which permits to design of a passivity-based controller with PI actions that ensures the asymptotic stability in the sense of Lyapunov. A linear estimator based on an integral estimator that allows reducing the number of current sensors required in the control implementation stage is used to determine the value of the unknown resistive load. The main advantage of this load estimator is that it ensures exponential convergence to the estimated variable. Numerical simulations and experimental validations show that the PI passivity-based control allows voltage regulation with first-order behavior, while the classical PI controller produces oscillations in the controlled variable, significantly when the load varies. |
format | Online Article Text |
id | pubmed-8512427 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-85124272021-10-14 Sensorless Adaptive Voltage Control for Classical DC-DC Converters Feeding Unknown Loads: A Generalized PI Passivity-Based Approach Gil-González, Walter Montoya, Oscar Danilo Restrepo, Carlos Hernández, Jesus C. Sensors (Basel) Article The problem of voltage regulation in unknown constant resistive loads is addressed in this paper from the nonlinear control point of view for second-order DC-DC converters. The converters’ topologies analyzed are: (i) buck converter, (ii) boost converter, (iii) buck-boost converter, and (iv) non-inverting buck-boost converter. The averaging modeling method is used to model these converters, representing all these converter topologies with a generalized port-Controlled Hamiltonian (PCH) representation. The PCH representation shows that the second-order DC-DC converters exhibit a general bilinear structure which permits to design of a passivity-based controller with PI actions that ensures the asymptotic stability in the sense of Lyapunov. A linear estimator based on an integral estimator that allows reducing the number of current sensors required in the control implementation stage is used to determine the value of the unknown resistive load. The main advantage of this load estimator is that it ensures exponential convergence to the estimated variable. Numerical simulations and experimental validations show that the PI passivity-based control allows voltage regulation with first-order behavior, while the classical PI controller produces oscillations in the controlled variable, significantly when the load varies. MDPI 2021-09-24 /pmc/articles/PMC8512427/ /pubmed/34640687 http://dx.doi.org/10.3390/s21196367 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Gil-González, Walter Montoya, Oscar Danilo Restrepo, Carlos Hernández, Jesus C. Sensorless Adaptive Voltage Control for Classical DC-DC Converters Feeding Unknown Loads: A Generalized PI Passivity-Based Approach |
title | Sensorless Adaptive Voltage Control for Classical DC-DC Converters Feeding Unknown Loads: A Generalized PI Passivity-Based Approach |
title_full | Sensorless Adaptive Voltage Control for Classical DC-DC Converters Feeding Unknown Loads: A Generalized PI Passivity-Based Approach |
title_fullStr | Sensorless Adaptive Voltage Control for Classical DC-DC Converters Feeding Unknown Loads: A Generalized PI Passivity-Based Approach |
title_full_unstemmed | Sensorless Adaptive Voltage Control for Classical DC-DC Converters Feeding Unknown Loads: A Generalized PI Passivity-Based Approach |
title_short | Sensorless Adaptive Voltage Control for Classical DC-DC Converters Feeding Unknown Loads: A Generalized PI Passivity-Based Approach |
title_sort | sensorless adaptive voltage control for classical dc-dc converters feeding unknown loads: a generalized pi passivity-based approach |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512427/ https://www.ncbi.nlm.nih.gov/pubmed/34640687 http://dx.doi.org/10.3390/s21196367 |
work_keys_str_mv | AT gilgonzalezwalter sensorlessadaptivevoltagecontrolforclassicaldcdcconvertersfeedingunknownloadsageneralizedpipassivitybasedapproach AT montoyaoscardanilo sensorlessadaptivevoltagecontrolforclassicaldcdcconvertersfeedingunknownloadsageneralizedpipassivitybasedapproach AT restrepocarlos sensorlessadaptivevoltagecontrolforclassicaldcdcconvertersfeedingunknownloadsageneralizedpipassivitybasedapproach AT hernandezjesusc sensorlessadaptivevoltagecontrolforclassicaldcdcconvertersfeedingunknownloadsageneralizedpipassivitybasedapproach |