Cargando…

Isolating Specific vs. Non-Specific Binding Responses in Conducting Polymer Biosensors for Bio-Fingerprinting

A longstanding challenge for accurate sensing of biomolecules such as proteins concerns specifically detecting a target analyte in a complex sample (e.g., food) without suffering from nonspecific binding or interactions from the target itself or other analytes present in the sample. Every sensor suf...

Descripción completa

Detalles Bibliográficos
Autores principales: Smith, Phil M., Sutradhar, Indorica, Telmer, Maxwell, Magar, Rishikesh, Farimani, Amir Barati, Reeja-Jayan, B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512428/
https://www.ncbi.nlm.nih.gov/pubmed/34640658
http://dx.doi.org/10.3390/s21196335
_version_ 1784582988564004864
author Smith, Phil M.
Sutradhar, Indorica
Telmer, Maxwell
Magar, Rishikesh
Farimani, Amir Barati
Reeja-Jayan, B.
author_facet Smith, Phil M.
Sutradhar, Indorica
Telmer, Maxwell
Magar, Rishikesh
Farimani, Amir Barati
Reeja-Jayan, B.
author_sort Smith, Phil M.
collection PubMed
description A longstanding challenge for accurate sensing of biomolecules such as proteins concerns specifically detecting a target analyte in a complex sample (e.g., food) without suffering from nonspecific binding or interactions from the target itself or other analytes present in the sample. Every sensor suffers from this fundamental drawback, which limits its sensitivity, specificity, and longevity. Existing efforts to improve signal-to-noise ratio involve introducing additional steps to reduce nonspecific binding, which increases the cost of the sensor. Conducting polymer-based chemiresistive biosensors can be mechanically flexible, are inexpensive, label-free, and capable of detecting specific biomolecules in complex samples without purification steps, making them very versatile. In this paper, a poly (3,4-ethylenedioxyphene) (PEDOT) and poly (3-thiopheneethanol) (3TE) interpenetrating network on polypropylene–cellulose fabric is used as a platform for a chemiresistive biosensor, and the specific and nonspecific binding events are studied using the Biotin/Avidin and Gliadin/G12-specific complementary binding pairs. We observed that specific binding between these pairs results in a negative ΔR with the addition of the analyte and this response increases with increasing analyte concentration. Nonspecific binding was found to have the opposite response, a positive ΔR upon the addition of analyte was seen in nonspecific binding cases. We further demonstrate the ability of the sensor to detect a targeted protein in a dual-protein analyte solution. The machine-learning classifier, random forest, predicted the presence of Biotin with 75% accuracy in dual-analyte solutions. This capability of distinguishing between specific and nonspecific binding can be a step towards solving the problem of false positives or false negatives to which all biosensors are susceptible.
format Online
Article
Text
id pubmed-8512428
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85124282021-10-14 Isolating Specific vs. Non-Specific Binding Responses in Conducting Polymer Biosensors for Bio-Fingerprinting Smith, Phil M. Sutradhar, Indorica Telmer, Maxwell Magar, Rishikesh Farimani, Amir Barati Reeja-Jayan, B. Sensors (Basel) Communication A longstanding challenge for accurate sensing of biomolecules such as proteins concerns specifically detecting a target analyte in a complex sample (e.g., food) without suffering from nonspecific binding or interactions from the target itself or other analytes present in the sample. Every sensor suffers from this fundamental drawback, which limits its sensitivity, specificity, and longevity. Existing efforts to improve signal-to-noise ratio involve introducing additional steps to reduce nonspecific binding, which increases the cost of the sensor. Conducting polymer-based chemiresistive biosensors can be mechanically flexible, are inexpensive, label-free, and capable of detecting specific biomolecules in complex samples without purification steps, making them very versatile. In this paper, a poly (3,4-ethylenedioxyphene) (PEDOT) and poly (3-thiopheneethanol) (3TE) interpenetrating network on polypropylene–cellulose fabric is used as a platform for a chemiresistive biosensor, and the specific and nonspecific binding events are studied using the Biotin/Avidin and Gliadin/G12-specific complementary binding pairs. We observed that specific binding between these pairs results in a negative ΔR with the addition of the analyte and this response increases with increasing analyte concentration. Nonspecific binding was found to have the opposite response, a positive ΔR upon the addition of analyte was seen in nonspecific binding cases. We further demonstrate the ability of the sensor to detect a targeted protein in a dual-protein analyte solution. The machine-learning classifier, random forest, predicted the presence of Biotin with 75% accuracy in dual-analyte solutions. This capability of distinguishing between specific and nonspecific binding can be a step towards solving the problem of false positives or false negatives to which all biosensors are susceptible. MDPI 2021-09-22 /pmc/articles/PMC8512428/ /pubmed/34640658 http://dx.doi.org/10.3390/s21196335 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Smith, Phil M.
Sutradhar, Indorica
Telmer, Maxwell
Magar, Rishikesh
Farimani, Amir Barati
Reeja-Jayan, B.
Isolating Specific vs. Non-Specific Binding Responses in Conducting Polymer Biosensors for Bio-Fingerprinting
title Isolating Specific vs. Non-Specific Binding Responses in Conducting Polymer Biosensors for Bio-Fingerprinting
title_full Isolating Specific vs. Non-Specific Binding Responses in Conducting Polymer Biosensors for Bio-Fingerprinting
title_fullStr Isolating Specific vs. Non-Specific Binding Responses in Conducting Polymer Biosensors for Bio-Fingerprinting
title_full_unstemmed Isolating Specific vs. Non-Specific Binding Responses in Conducting Polymer Biosensors for Bio-Fingerprinting
title_short Isolating Specific vs. Non-Specific Binding Responses in Conducting Polymer Biosensors for Bio-Fingerprinting
title_sort isolating specific vs. non-specific binding responses in conducting polymer biosensors for bio-fingerprinting
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512428/
https://www.ncbi.nlm.nih.gov/pubmed/34640658
http://dx.doi.org/10.3390/s21196335
work_keys_str_mv AT smithphilm isolatingspecificvsnonspecificbindingresponsesinconductingpolymerbiosensorsforbiofingerprinting
AT sutradharindorica isolatingspecificvsnonspecificbindingresponsesinconductingpolymerbiosensorsforbiofingerprinting
AT telmermaxwell isolatingspecificvsnonspecificbindingresponsesinconductingpolymerbiosensorsforbiofingerprinting
AT magarrishikesh isolatingspecificvsnonspecificbindingresponsesinconductingpolymerbiosensorsforbiofingerprinting
AT farimaniamirbarati isolatingspecificvsnonspecificbindingresponsesinconductingpolymerbiosensorsforbiofingerprinting
AT reejajayanb isolatingspecificvsnonspecificbindingresponsesinconductingpolymerbiosensorsforbiofingerprinting