Cargando…

Evidence for the Effectiveness of Feedback from Wearable Inertial Sensors during Work-Related Activities: A Scoping Review

Background: Wearable inertial sensor technology (WIST) systems provide feedback, aiming to modify aberrant postures and movements. The literature on the effects of feedback from WIST during work or work-related activities has not been previously summarised. This review examines the effectiveness of...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Roger, James, Carole, Edwards, Suzi, Skinner, Geoff, Young, Jodi L., Snodgrass, Suzanne J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512480/
https://www.ncbi.nlm.nih.gov/pubmed/34640695
http://dx.doi.org/10.3390/s21196377
_version_ 1784583001163694080
author Lee, Roger
James, Carole
Edwards, Suzi
Skinner, Geoff
Young, Jodi L.
Snodgrass, Suzanne J.
author_facet Lee, Roger
James, Carole
Edwards, Suzi
Skinner, Geoff
Young, Jodi L.
Snodgrass, Suzanne J.
author_sort Lee, Roger
collection PubMed
description Background: Wearable inertial sensor technology (WIST) systems provide feedback, aiming to modify aberrant postures and movements. The literature on the effects of feedback from WIST during work or work-related activities has not been previously summarised. This review examines the effectiveness of feedback on upper body kinematics during work or work-related activities, along with the wearability and a quantification of the kinematics of the related device. Methods: The Cinahl, Cochrane, Embase, Medline, Scopus, Sportdiscus and Google Scholar databases were searched, including reports from January 2005 to July 2021. The included studies were summarised descriptively and the evidence was assessed. Results: Fourteen included studies demonstrated a ‘limited’ level of evidence supporting posture and/or movement behaviour improvements using WIST feedback, with no improvements in pain. One study assessed wearability and another two investigated comfort. Studies used tri-axial accelerometers or IMU integration (n = 5 studies). Visual and/or vibrotactile feedback was mostly used. Most studies had a risk of bias, lacked detail for methodological reproducibility and displayed inconsistent reporting of sensor technology, with validation provided only in one study. Thus, we have proposed a minimum ‘Technology and Design Checklist’ for reporting. Conclusions: Our findings suggest that WIST may improve posture, though not pain; however, the quality of the studies limits the strength of this conclusion. Wearability evaluations are needed for the translation of WIST outcomes. Minimum reporting standards for WIST should be followed to ensure methodological reproducibility.
format Online
Article
Text
id pubmed-8512480
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85124802021-10-14 Evidence for the Effectiveness of Feedback from Wearable Inertial Sensors during Work-Related Activities: A Scoping Review Lee, Roger James, Carole Edwards, Suzi Skinner, Geoff Young, Jodi L. Snodgrass, Suzanne J. Sensors (Basel) Review Background: Wearable inertial sensor technology (WIST) systems provide feedback, aiming to modify aberrant postures and movements. The literature on the effects of feedback from WIST during work or work-related activities has not been previously summarised. This review examines the effectiveness of feedback on upper body kinematics during work or work-related activities, along with the wearability and a quantification of the kinematics of the related device. Methods: The Cinahl, Cochrane, Embase, Medline, Scopus, Sportdiscus and Google Scholar databases were searched, including reports from January 2005 to July 2021. The included studies were summarised descriptively and the evidence was assessed. Results: Fourteen included studies demonstrated a ‘limited’ level of evidence supporting posture and/or movement behaviour improvements using WIST feedback, with no improvements in pain. One study assessed wearability and another two investigated comfort. Studies used tri-axial accelerometers or IMU integration (n = 5 studies). Visual and/or vibrotactile feedback was mostly used. Most studies had a risk of bias, lacked detail for methodological reproducibility and displayed inconsistent reporting of sensor technology, with validation provided only in one study. Thus, we have proposed a minimum ‘Technology and Design Checklist’ for reporting. Conclusions: Our findings suggest that WIST may improve posture, though not pain; however, the quality of the studies limits the strength of this conclusion. Wearability evaluations are needed for the translation of WIST outcomes. Minimum reporting standards for WIST should be followed to ensure methodological reproducibility. MDPI 2021-09-24 /pmc/articles/PMC8512480/ /pubmed/34640695 http://dx.doi.org/10.3390/s21196377 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Lee, Roger
James, Carole
Edwards, Suzi
Skinner, Geoff
Young, Jodi L.
Snodgrass, Suzanne J.
Evidence for the Effectiveness of Feedback from Wearable Inertial Sensors during Work-Related Activities: A Scoping Review
title Evidence for the Effectiveness of Feedback from Wearable Inertial Sensors during Work-Related Activities: A Scoping Review
title_full Evidence for the Effectiveness of Feedback from Wearable Inertial Sensors during Work-Related Activities: A Scoping Review
title_fullStr Evidence for the Effectiveness of Feedback from Wearable Inertial Sensors during Work-Related Activities: A Scoping Review
title_full_unstemmed Evidence for the Effectiveness of Feedback from Wearable Inertial Sensors during Work-Related Activities: A Scoping Review
title_short Evidence for the Effectiveness of Feedback from Wearable Inertial Sensors during Work-Related Activities: A Scoping Review
title_sort evidence for the effectiveness of feedback from wearable inertial sensors during work-related activities: a scoping review
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512480/
https://www.ncbi.nlm.nih.gov/pubmed/34640695
http://dx.doi.org/10.3390/s21196377
work_keys_str_mv AT leeroger evidencefortheeffectivenessoffeedbackfromwearableinertialsensorsduringworkrelatedactivitiesascopingreview
AT jamescarole evidencefortheeffectivenessoffeedbackfromwearableinertialsensorsduringworkrelatedactivitiesascopingreview
AT edwardssuzi evidencefortheeffectivenessoffeedbackfromwearableinertialsensorsduringworkrelatedactivitiesascopingreview
AT skinnergeoff evidencefortheeffectivenessoffeedbackfromwearableinertialsensorsduringworkrelatedactivitiesascopingreview
AT youngjodil evidencefortheeffectivenessoffeedbackfromwearableinertialsensorsduringworkrelatedactivitiesascopingreview
AT snodgrasssuzannej evidencefortheeffectivenessoffeedbackfromwearableinertialsensorsduringworkrelatedactivitiesascopingreview