Cargando…

A Miniature, Fiber-Optic Vibrometer for Measuring Unintended Acoustic Output of Active Hearing Implants during Magnetic Resonance Imaging

Making use of magnetic resonance imaging (MRI) for diagnostics on patients with implanted medical devices requires caution due to mutual interactions between the device and the electromagnetic fields used by the scanner that can cause a number of adverse events. The presented study offers a novel te...

Descripción completa

Detalles Bibliográficos
Autores principales: Fierens, Guy, Walraevens, Joris, Peeters, Ronald, Verhaert, Nicolas, Glorieux, Christ
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512570/
https://www.ncbi.nlm.nih.gov/pubmed/34640909
http://dx.doi.org/10.3390/s21196589
_version_ 1784583025367973888
author Fierens, Guy
Walraevens, Joris
Peeters, Ronald
Verhaert, Nicolas
Glorieux, Christ
author_facet Fierens, Guy
Walraevens, Joris
Peeters, Ronald
Verhaert, Nicolas
Glorieux, Christ
author_sort Fierens, Guy
collection PubMed
description Making use of magnetic resonance imaging (MRI) for diagnostics on patients with implanted medical devices requires caution due to mutual interactions between the device and the electromagnetic fields used by the scanner that can cause a number of adverse events. The presented study offers a novel test method to quantify the risk of unintended output of acoustically stimulating hearing implants. The design and operating principle of an all-optical, MRI safe vibrometer is outlined, followed by an experimental verification of a prototype. Results obtained in an MRI environment indicate that the system can detect peak displacements down to 8 pm for audible frequencies. Feasibility testing was performed with an active middle ear implant that was exposed to several pulse sequences in a 1.5 Tesla MRI environment. Magnetic field induced actuator vibrations, measured during scanning, turned out to be equivalent to estimated sound pressure levels between 25 and 85 dB SPL, depending on the signal frequency. These sound pressure levels are situated well below ambient sound pressure levels generated by the MRI scanning process. The presented case study therefore indicates a limited risk of audible unintended output for the examined hearing implant during MRI.
format Online
Article
Text
id pubmed-8512570
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85125702021-10-14 A Miniature, Fiber-Optic Vibrometer for Measuring Unintended Acoustic Output of Active Hearing Implants during Magnetic Resonance Imaging Fierens, Guy Walraevens, Joris Peeters, Ronald Verhaert, Nicolas Glorieux, Christ Sensors (Basel) Article Making use of magnetic resonance imaging (MRI) for diagnostics on patients with implanted medical devices requires caution due to mutual interactions between the device and the electromagnetic fields used by the scanner that can cause a number of adverse events. The presented study offers a novel test method to quantify the risk of unintended output of acoustically stimulating hearing implants. The design and operating principle of an all-optical, MRI safe vibrometer is outlined, followed by an experimental verification of a prototype. Results obtained in an MRI environment indicate that the system can detect peak displacements down to 8 pm for audible frequencies. Feasibility testing was performed with an active middle ear implant that was exposed to several pulse sequences in a 1.5 Tesla MRI environment. Magnetic field induced actuator vibrations, measured during scanning, turned out to be equivalent to estimated sound pressure levels between 25 and 85 dB SPL, depending on the signal frequency. These sound pressure levels are situated well below ambient sound pressure levels generated by the MRI scanning process. The presented case study therefore indicates a limited risk of audible unintended output for the examined hearing implant during MRI. MDPI 2021-10-02 /pmc/articles/PMC8512570/ /pubmed/34640909 http://dx.doi.org/10.3390/s21196589 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Fierens, Guy
Walraevens, Joris
Peeters, Ronald
Verhaert, Nicolas
Glorieux, Christ
A Miniature, Fiber-Optic Vibrometer for Measuring Unintended Acoustic Output of Active Hearing Implants during Magnetic Resonance Imaging
title A Miniature, Fiber-Optic Vibrometer for Measuring Unintended Acoustic Output of Active Hearing Implants during Magnetic Resonance Imaging
title_full A Miniature, Fiber-Optic Vibrometer for Measuring Unintended Acoustic Output of Active Hearing Implants during Magnetic Resonance Imaging
title_fullStr A Miniature, Fiber-Optic Vibrometer for Measuring Unintended Acoustic Output of Active Hearing Implants during Magnetic Resonance Imaging
title_full_unstemmed A Miniature, Fiber-Optic Vibrometer for Measuring Unintended Acoustic Output of Active Hearing Implants during Magnetic Resonance Imaging
title_short A Miniature, Fiber-Optic Vibrometer for Measuring Unintended Acoustic Output of Active Hearing Implants during Magnetic Resonance Imaging
title_sort miniature, fiber-optic vibrometer for measuring unintended acoustic output of active hearing implants during magnetic resonance imaging
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512570/
https://www.ncbi.nlm.nih.gov/pubmed/34640909
http://dx.doi.org/10.3390/s21196589
work_keys_str_mv AT fierensguy aminiaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging
AT walraevensjoris aminiaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging
AT peetersronald aminiaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging
AT verhaertnicolas aminiaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging
AT glorieuxchrist aminiaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging
AT fierensguy miniaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging
AT walraevensjoris miniaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging
AT peetersronald miniaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging
AT verhaertnicolas miniaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging
AT glorieuxchrist miniaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging