Cargando…
A Miniature, Fiber-Optic Vibrometer for Measuring Unintended Acoustic Output of Active Hearing Implants during Magnetic Resonance Imaging
Making use of magnetic resonance imaging (MRI) for diagnostics on patients with implanted medical devices requires caution due to mutual interactions between the device and the electromagnetic fields used by the scanner that can cause a number of adverse events. The presented study offers a novel te...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512570/ https://www.ncbi.nlm.nih.gov/pubmed/34640909 http://dx.doi.org/10.3390/s21196589 |
_version_ | 1784583025367973888 |
---|---|
author | Fierens, Guy Walraevens, Joris Peeters, Ronald Verhaert, Nicolas Glorieux, Christ |
author_facet | Fierens, Guy Walraevens, Joris Peeters, Ronald Verhaert, Nicolas Glorieux, Christ |
author_sort | Fierens, Guy |
collection | PubMed |
description | Making use of magnetic resonance imaging (MRI) for diagnostics on patients with implanted medical devices requires caution due to mutual interactions between the device and the electromagnetic fields used by the scanner that can cause a number of adverse events. The presented study offers a novel test method to quantify the risk of unintended output of acoustically stimulating hearing implants. The design and operating principle of an all-optical, MRI safe vibrometer is outlined, followed by an experimental verification of a prototype. Results obtained in an MRI environment indicate that the system can detect peak displacements down to 8 pm for audible frequencies. Feasibility testing was performed with an active middle ear implant that was exposed to several pulse sequences in a 1.5 Tesla MRI environment. Magnetic field induced actuator vibrations, measured during scanning, turned out to be equivalent to estimated sound pressure levels between 25 and 85 dB SPL, depending on the signal frequency. These sound pressure levels are situated well below ambient sound pressure levels generated by the MRI scanning process. The presented case study therefore indicates a limited risk of audible unintended output for the examined hearing implant during MRI. |
format | Online Article Text |
id | pubmed-8512570 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-85125702021-10-14 A Miniature, Fiber-Optic Vibrometer for Measuring Unintended Acoustic Output of Active Hearing Implants during Magnetic Resonance Imaging Fierens, Guy Walraevens, Joris Peeters, Ronald Verhaert, Nicolas Glorieux, Christ Sensors (Basel) Article Making use of magnetic resonance imaging (MRI) for diagnostics on patients with implanted medical devices requires caution due to mutual interactions between the device and the electromagnetic fields used by the scanner that can cause a number of adverse events. The presented study offers a novel test method to quantify the risk of unintended output of acoustically stimulating hearing implants. The design and operating principle of an all-optical, MRI safe vibrometer is outlined, followed by an experimental verification of a prototype. Results obtained in an MRI environment indicate that the system can detect peak displacements down to 8 pm for audible frequencies. Feasibility testing was performed with an active middle ear implant that was exposed to several pulse sequences in a 1.5 Tesla MRI environment. Magnetic field induced actuator vibrations, measured during scanning, turned out to be equivalent to estimated sound pressure levels between 25 and 85 dB SPL, depending on the signal frequency. These sound pressure levels are situated well below ambient sound pressure levels generated by the MRI scanning process. The presented case study therefore indicates a limited risk of audible unintended output for the examined hearing implant during MRI. MDPI 2021-10-02 /pmc/articles/PMC8512570/ /pubmed/34640909 http://dx.doi.org/10.3390/s21196589 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Fierens, Guy Walraevens, Joris Peeters, Ronald Verhaert, Nicolas Glorieux, Christ A Miniature, Fiber-Optic Vibrometer for Measuring Unintended Acoustic Output of Active Hearing Implants during Magnetic Resonance Imaging |
title | A Miniature, Fiber-Optic Vibrometer for Measuring Unintended Acoustic Output of Active Hearing Implants during Magnetic Resonance Imaging |
title_full | A Miniature, Fiber-Optic Vibrometer for Measuring Unintended Acoustic Output of Active Hearing Implants during Magnetic Resonance Imaging |
title_fullStr | A Miniature, Fiber-Optic Vibrometer for Measuring Unintended Acoustic Output of Active Hearing Implants during Magnetic Resonance Imaging |
title_full_unstemmed | A Miniature, Fiber-Optic Vibrometer for Measuring Unintended Acoustic Output of Active Hearing Implants during Magnetic Resonance Imaging |
title_short | A Miniature, Fiber-Optic Vibrometer for Measuring Unintended Acoustic Output of Active Hearing Implants during Magnetic Resonance Imaging |
title_sort | miniature, fiber-optic vibrometer for measuring unintended acoustic output of active hearing implants during magnetic resonance imaging |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512570/ https://www.ncbi.nlm.nih.gov/pubmed/34640909 http://dx.doi.org/10.3390/s21196589 |
work_keys_str_mv | AT fierensguy aminiaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging AT walraevensjoris aminiaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging AT peetersronald aminiaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging AT verhaertnicolas aminiaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging AT glorieuxchrist aminiaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging AT fierensguy miniaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging AT walraevensjoris miniaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging AT peetersronald miniaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging AT verhaertnicolas miniaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging AT glorieuxchrist miniaturefiberopticvibrometerformeasuringunintendedacousticoutputofactivehearingimplantsduringmagneticresonanceimaging |