Optimal Localization of Smart Aggregate Sensor for Concrete Damage Monitoring in PSC Anchorage Zone

This study investigates the feasibility of smart aggregate (SA) sensors and their optimal locations for impedance-based damage monitoring in prestressed concrete (PSC) anchorage zones. Firstly, numerical stress analyses are performed on the PSC anchorage zone to determine the location of potential d...

Descripción completa

Detalles Bibliográficos
Autores principales: Pham, Quang-Quang, Dang, Ngoc-Loi, Ta, Quoc-Bao, Kim, Jeong-Tae
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512732/
https://www.ncbi.nlm.nih.gov/pubmed/34640655
http://dx.doi.org/10.3390/s21196337
_version_ 1784583065714032640
author Pham, Quang-Quang
Dang, Ngoc-Loi
Ta, Quoc-Bao
Kim, Jeong-Tae
author_facet Pham, Quang-Quang
Dang, Ngoc-Loi
Ta, Quoc-Bao
Kim, Jeong-Tae
author_sort Pham, Quang-Quang
collection PubMed
description This study investigates the feasibility of smart aggregate (SA) sensors and their optimal locations for impedance-based damage monitoring in prestressed concrete (PSC) anchorage zones. Firstly, numerical stress analyses are performed on the PSC anchorage zone to determine the location of potential damage that is induced by prestressing forces. Secondly, a simplified impedance model is briefly described for the SA sensor in the anchorage. Thirdly, numerical impedance analyses are performed to explore the sensitivities of a few SA sensors in the anchorage zone under the variation of prestressing forces and under the occurrence of artificial damage events. Finally, a real-scale PSC anchorage zone is experimentally examined to evaluate the optimal localization of the SA sensor for concrete damage detection. Impedance responses measured under a series of prestressing forces are statistically quantified to estimate the performance of damage monitoring via the SA sensor in the PSC anchorage.
format Online
Article
Text
id pubmed-8512732
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85127322021-10-14 Optimal Localization of Smart Aggregate Sensor for Concrete Damage Monitoring in PSC Anchorage Zone Pham, Quang-Quang Dang, Ngoc-Loi Ta, Quoc-Bao Kim, Jeong-Tae Sensors (Basel) Article This study investigates the feasibility of smart aggregate (SA) sensors and their optimal locations for impedance-based damage monitoring in prestressed concrete (PSC) anchorage zones. Firstly, numerical stress analyses are performed on the PSC anchorage zone to determine the location of potential damage that is induced by prestressing forces. Secondly, a simplified impedance model is briefly described for the SA sensor in the anchorage. Thirdly, numerical impedance analyses are performed to explore the sensitivities of a few SA sensors in the anchorage zone under the variation of prestressing forces and under the occurrence of artificial damage events. Finally, a real-scale PSC anchorage zone is experimentally examined to evaluate the optimal localization of the SA sensor for concrete damage detection. Impedance responses measured under a series of prestressing forces are statistically quantified to estimate the performance of damage monitoring via the SA sensor in the PSC anchorage. MDPI 2021-09-22 /pmc/articles/PMC8512732/ /pubmed/34640655 http://dx.doi.org/10.3390/s21196337 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Pham, Quang-Quang
Dang, Ngoc-Loi
Ta, Quoc-Bao
Kim, Jeong-Tae
Optimal Localization of Smart Aggregate Sensor for Concrete Damage Monitoring in PSC Anchorage Zone
title Optimal Localization of Smart Aggregate Sensor for Concrete Damage Monitoring in PSC Anchorage Zone
title_full Optimal Localization of Smart Aggregate Sensor for Concrete Damage Monitoring in PSC Anchorage Zone
title_fullStr Optimal Localization of Smart Aggregate Sensor for Concrete Damage Monitoring in PSC Anchorage Zone
title_full_unstemmed Optimal Localization of Smart Aggregate Sensor for Concrete Damage Monitoring in PSC Anchorage Zone
title_short Optimal Localization of Smart Aggregate Sensor for Concrete Damage Monitoring in PSC Anchorage Zone
title_sort optimal localization of smart aggregate sensor for concrete damage monitoring in psc anchorage zone
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512732/
https://www.ncbi.nlm.nih.gov/pubmed/34640655
http://dx.doi.org/10.3390/s21196337
work_keys_str_mv AT phamquangquang optimallocalizationofsmartaggregatesensorforconcretedamagemonitoringinpscanchoragezone
AT dangngocloi optimallocalizationofsmartaggregatesensorforconcretedamagemonitoringinpscanchoragezone
AT taquocbao optimallocalizationofsmartaggregatesensorforconcretedamagemonitoringinpscanchoragezone
AT kimjeongtae optimallocalizationofsmartaggregatesensorforconcretedamagemonitoringinpscanchoragezone