Cargando…

Modified Thermocouple Sensor and External Reference Junction Enhance Accuracy in Indoor Air Temperature Measurements

Indoor air temperature belongs to the most important climatic variables in indoor climate research, affecting thermal comfort, energy balance, and air movement in buildings. This paper focuses on measurement errors when using thermocouples in indoor temperature measurements, with special attention o...

Descripción completa

Detalles Bibliográficos
Autores principales: Lundström, Hans, Mattsson, Magnus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512746/
https://www.ncbi.nlm.nih.gov/pubmed/34640897
http://dx.doi.org/10.3390/s21196577
_version_ 1784583069175382016
author Lundström, Hans
Mattsson, Magnus
author_facet Lundström, Hans
Mattsson, Magnus
author_sort Lundström, Hans
collection PubMed
description Indoor air temperature belongs to the most important climatic variables in indoor climate research, affecting thermal comfort, energy balance, and air movement in buildings. This paper focuses on measurement errors when using thermocouples in indoor temperature measurements, with special attention on measurements of air temperature. We briefly discuss errors in thermocouple measurements, noting that, for temperatures restricted to indoor temperature ranges, a thermocouple Type T performs much better than stated in “standards”. When thermocouples are described in the literature, industrial applications are primarily considered, involving temperatures up to several hundred degrees and with moderate demands on accuracy. In indoor applications, the temperature difference between the measuring and the reference junction is often only a few degrees. Thus, the error contribution from the thermocouple itself is almost immeasurable, while the dominant error source is in the internal reference temperature compensation in the measuring instrument. It was shown that using an external reference junction can decrease the measurement error substantially (i.e., down to a few hundredths of a degree) in room temperature measurements. One example of how such a device may be assembled is provided. A special application of room temperature measurements involves measuring indoor air temperature. Here, errors, due to radiation influence on the sensor from surrounding surfaces, were surprisingly high. The means to estimate the radiative influence on typical thermocouples are presented, along with suggestions for modification of thermocouple sensors to lower the radiation impact and thereby improve the measurement accuracy.
format Online
Article
Text
id pubmed-8512746
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85127462021-10-14 Modified Thermocouple Sensor and External Reference Junction Enhance Accuracy in Indoor Air Temperature Measurements Lundström, Hans Mattsson, Magnus Sensors (Basel) Article Indoor air temperature belongs to the most important climatic variables in indoor climate research, affecting thermal comfort, energy balance, and air movement in buildings. This paper focuses on measurement errors when using thermocouples in indoor temperature measurements, with special attention on measurements of air temperature. We briefly discuss errors in thermocouple measurements, noting that, for temperatures restricted to indoor temperature ranges, a thermocouple Type T performs much better than stated in “standards”. When thermocouples are described in the literature, industrial applications are primarily considered, involving temperatures up to several hundred degrees and with moderate demands on accuracy. In indoor applications, the temperature difference between the measuring and the reference junction is often only a few degrees. Thus, the error contribution from the thermocouple itself is almost immeasurable, while the dominant error source is in the internal reference temperature compensation in the measuring instrument. It was shown that using an external reference junction can decrease the measurement error substantially (i.e., down to a few hundredths of a degree) in room temperature measurements. One example of how such a device may be assembled is provided. A special application of room temperature measurements involves measuring indoor air temperature. Here, errors, due to radiation influence on the sensor from surrounding surfaces, were surprisingly high. The means to estimate the radiative influence on typical thermocouples are presented, along with suggestions for modification of thermocouple sensors to lower the radiation impact and thereby improve the measurement accuracy. MDPI 2021-10-01 /pmc/articles/PMC8512746/ /pubmed/34640897 http://dx.doi.org/10.3390/s21196577 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lundström, Hans
Mattsson, Magnus
Modified Thermocouple Sensor and External Reference Junction Enhance Accuracy in Indoor Air Temperature Measurements
title Modified Thermocouple Sensor and External Reference Junction Enhance Accuracy in Indoor Air Temperature Measurements
title_full Modified Thermocouple Sensor and External Reference Junction Enhance Accuracy in Indoor Air Temperature Measurements
title_fullStr Modified Thermocouple Sensor and External Reference Junction Enhance Accuracy in Indoor Air Temperature Measurements
title_full_unstemmed Modified Thermocouple Sensor and External Reference Junction Enhance Accuracy in Indoor Air Temperature Measurements
title_short Modified Thermocouple Sensor and External Reference Junction Enhance Accuracy in Indoor Air Temperature Measurements
title_sort modified thermocouple sensor and external reference junction enhance accuracy in indoor air temperature measurements
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512746/
https://www.ncbi.nlm.nih.gov/pubmed/34640897
http://dx.doi.org/10.3390/s21196577
work_keys_str_mv AT lundstromhans modifiedthermocouplesensorandexternalreferencejunctionenhanceaccuracyinindoorairtemperaturemeasurements
AT mattssonmagnus modifiedthermocouplesensorandexternalreferencejunctionenhanceaccuracyinindoorairtemperaturemeasurements