Cargando…
Meander Thin-Film Biosensor Fabrication to Investigate the Influence of Structural Parameters on the Magneto-Impedance Effect
Thin-film magneto-impedance (MI) biosensors have attracted significant attention due to their high sensitivity and easy miniaturization. However, further improvement is required to detect weak biomagnetic signals. Here, we report a meander thin-film biosensor preparation to investigate the fabricati...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512765/ https://www.ncbi.nlm.nih.gov/pubmed/34640832 http://dx.doi.org/10.3390/s21196514 |
_version_ | 1784583075119759360 |
---|---|
author | Sayad, Abkar Uddin, Shah Mukim Chan, Jianxiong Skafidas, Efstratios Kwan, Patrick |
author_facet | Sayad, Abkar Uddin, Shah Mukim Chan, Jianxiong Skafidas, Efstratios Kwan, Patrick |
author_sort | Sayad, Abkar |
collection | PubMed |
description | Thin-film magneto-impedance (MI) biosensors have attracted significant attention due to their high sensitivity and easy miniaturization. However, further improvement is required to detect weak biomagnetic signals. Here, we report a meander thin-film biosensor preparation to investigate the fabrication parameters influencing the MI effect. Specifically, we hypothesized that an optimal film thickness and sensing area size ratio could be achieved to obtain a maximum MI ratio. A meander multilayer MI biosensor based on a NiFe/Cu/NiFe thin-film was designed and fabricated into 3-, 6-, and 9-turn models with film thicknesses of 3 µm and 6 µm. The 9-turn biosensor resembled the largest sensing area, while the 3- and 6-turn biosensors were designed with identical sensing areas. The results indicated that the NiFe film thickness of 6 µm with a sensing area size of 14.4 mm(2) resembling a 9-turn MI biosensor is the optimal ratio yielding the maximum MI ratio of 238%, which is 70% larger than the 3- and 6-turn structures. The 3- and 6-turn MI biosensors exhibited similar characteristics where the MI ratio peaked at a similar value. Our results suggest that the MI ratio can be increased by increasing the sensing area size and film thickness rather than the number of turns. We showed that an optimal film thickness to sensing area size ratio is required to obtain a high MI ratio. Our findings will be useful for designing highly sensitive MI biosensors capable of detecting low biomagnetic signals. |
format | Online Article Text |
id | pubmed-8512765 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-85127652021-10-14 Meander Thin-Film Biosensor Fabrication to Investigate the Influence of Structural Parameters on the Magneto-Impedance Effect Sayad, Abkar Uddin, Shah Mukim Chan, Jianxiong Skafidas, Efstratios Kwan, Patrick Sensors (Basel) Article Thin-film magneto-impedance (MI) biosensors have attracted significant attention due to their high sensitivity and easy miniaturization. However, further improvement is required to detect weak biomagnetic signals. Here, we report a meander thin-film biosensor preparation to investigate the fabrication parameters influencing the MI effect. Specifically, we hypothesized that an optimal film thickness and sensing area size ratio could be achieved to obtain a maximum MI ratio. A meander multilayer MI biosensor based on a NiFe/Cu/NiFe thin-film was designed and fabricated into 3-, 6-, and 9-turn models with film thicknesses of 3 µm and 6 µm. The 9-turn biosensor resembled the largest sensing area, while the 3- and 6-turn biosensors were designed with identical sensing areas. The results indicated that the NiFe film thickness of 6 µm with a sensing area size of 14.4 mm(2) resembling a 9-turn MI biosensor is the optimal ratio yielding the maximum MI ratio of 238%, which is 70% larger than the 3- and 6-turn structures. The 3- and 6-turn MI biosensors exhibited similar characteristics where the MI ratio peaked at a similar value. Our results suggest that the MI ratio can be increased by increasing the sensing area size and film thickness rather than the number of turns. We showed that an optimal film thickness to sensing area size ratio is required to obtain a high MI ratio. Our findings will be useful for designing highly sensitive MI biosensors capable of detecting low biomagnetic signals. MDPI 2021-09-29 /pmc/articles/PMC8512765/ /pubmed/34640832 http://dx.doi.org/10.3390/s21196514 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Sayad, Abkar Uddin, Shah Mukim Chan, Jianxiong Skafidas, Efstratios Kwan, Patrick Meander Thin-Film Biosensor Fabrication to Investigate the Influence of Structural Parameters on the Magneto-Impedance Effect |
title | Meander Thin-Film Biosensor Fabrication to Investigate the Influence of Structural Parameters on the Magneto-Impedance Effect |
title_full | Meander Thin-Film Biosensor Fabrication to Investigate the Influence of Structural Parameters on the Magneto-Impedance Effect |
title_fullStr | Meander Thin-Film Biosensor Fabrication to Investigate the Influence of Structural Parameters on the Magneto-Impedance Effect |
title_full_unstemmed | Meander Thin-Film Biosensor Fabrication to Investigate the Influence of Structural Parameters on the Magneto-Impedance Effect |
title_short | Meander Thin-Film Biosensor Fabrication to Investigate the Influence of Structural Parameters on the Magneto-Impedance Effect |
title_sort | meander thin-film biosensor fabrication to investigate the influence of structural parameters on the magneto-impedance effect |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512765/ https://www.ncbi.nlm.nih.gov/pubmed/34640832 http://dx.doi.org/10.3390/s21196514 |
work_keys_str_mv | AT sayadabkar meanderthinfilmbiosensorfabricationtoinvestigatetheinfluenceofstructuralparametersonthemagnetoimpedanceeffect AT uddinshahmukim meanderthinfilmbiosensorfabricationtoinvestigatetheinfluenceofstructuralparametersonthemagnetoimpedanceeffect AT chanjianxiong meanderthinfilmbiosensorfabricationtoinvestigatetheinfluenceofstructuralparametersonthemagnetoimpedanceeffect AT skafidasefstratios meanderthinfilmbiosensorfabricationtoinvestigatetheinfluenceofstructuralparametersonthemagnetoimpedanceeffect AT kwanpatrick meanderthinfilmbiosensorfabricationtoinvestigatetheinfluenceofstructuralparametersonthemagnetoimpedanceeffect |