Space-Filling Curve Resistor on Ultra-Thin Polyetherimide Foil for Strain Impervious Temperature Sensing

Monitoring process parameters in the manufacture of composite structures is key to ensuring product quality and safety. Ideally, this can be done by sensors that are embedded during production and can remain as devices to monitor structural health. Extremely thin foil-based sensors weaken the finish...

Descripción completa

Detalles Bibliográficos
Autores principales: Rager, Korbinian, Jaworski, David, von der Heide, Chresten, Kyriazis, Alexander, Sinapius, Michael, Constantinou, Iordania, Dietzel, Andreas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512779/
https://www.ncbi.nlm.nih.gov/pubmed/34640795
http://dx.doi.org/10.3390/s21196479
_version_ 1784583078616760320
author Rager, Korbinian
Jaworski, David
von der Heide, Chresten
Kyriazis, Alexander
Sinapius, Michael
Constantinou, Iordania
Dietzel, Andreas
author_facet Rager, Korbinian
Jaworski, David
von der Heide, Chresten
Kyriazis, Alexander
Sinapius, Michael
Constantinou, Iordania
Dietzel, Andreas
author_sort Rager, Korbinian
collection PubMed
description Monitoring process parameters in the manufacture of composite structures is key to ensuring product quality and safety. Ideally, this can be done by sensors that are embedded during production and can remain as devices to monitor structural health. Extremely thin foil-based sensors weaken the finished workpiece very little. Under ideal conditions, the foil substrate bonds with the resin in the autoclaving process, as is the case when polyetherimide is used. Here, we present a temperature sensor as part of an 8 µm thick multi-sensor node foil for monitoring processing conditions during the production and structural health during the lifetime of a construction. A metallic thin film conductor was shaped in the form of a space-filling curve to suppress the influences of resistance changes due to strain, which could otherwise interfere with the measurement of the temperature. FEM simulations as well as experiments confirm that this type of sensor is completely insensitive to the direction of strain and sufficiently insensitive to the amount of strain, so that mechanical strains that can occur in the composite curing process practically do not interfere with the temperature measurement. The temperature sensor is combined with a capacitive sensor for curing monitoring based on impedance measurement and a half-bridge strain gauge sensor element. All three types are made of the same materials and are manufactured together in one process flow. This is the key to cost-effective distributed sensor arrays that can be embedded during production and remain in the workpiece, thus ensuring not only the quality of the initial product but also the operational reliability during the service life of light-weight composite constructions.
format Online
Article
Text
id pubmed-8512779
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85127792021-10-14 Space-Filling Curve Resistor on Ultra-Thin Polyetherimide Foil for Strain Impervious Temperature Sensing Rager, Korbinian Jaworski, David von der Heide, Chresten Kyriazis, Alexander Sinapius, Michael Constantinou, Iordania Dietzel, Andreas Sensors (Basel) Article Monitoring process parameters in the manufacture of composite structures is key to ensuring product quality and safety. Ideally, this can be done by sensors that are embedded during production and can remain as devices to monitor structural health. Extremely thin foil-based sensors weaken the finished workpiece very little. Under ideal conditions, the foil substrate bonds with the resin in the autoclaving process, as is the case when polyetherimide is used. Here, we present a temperature sensor as part of an 8 µm thick multi-sensor node foil for monitoring processing conditions during the production and structural health during the lifetime of a construction. A metallic thin film conductor was shaped in the form of a space-filling curve to suppress the influences of resistance changes due to strain, which could otherwise interfere with the measurement of the temperature. FEM simulations as well as experiments confirm that this type of sensor is completely insensitive to the direction of strain and sufficiently insensitive to the amount of strain, so that mechanical strains that can occur in the composite curing process practically do not interfere with the temperature measurement. The temperature sensor is combined with a capacitive sensor for curing monitoring based on impedance measurement and a half-bridge strain gauge sensor element. All three types are made of the same materials and are manufactured together in one process flow. This is the key to cost-effective distributed sensor arrays that can be embedded during production and remain in the workpiece, thus ensuring not only the quality of the initial product but also the operational reliability during the service life of light-weight composite constructions. MDPI 2021-09-28 /pmc/articles/PMC8512779/ /pubmed/34640795 http://dx.doi.org/10.3390/s21196479 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Rager, Korbinian
Jaworski, David
von der Heide, Chresten
Kyriazis, Alexander
Sinapius, Michael
Constantinou, Iordania
Dietzel, Andreas
Space-Filling Curve Resistor on Ultra-Thin Polyetherimide Foil for Strain Impervious Temperature Sensing
title Space-Filling Curve Resistor on Ultra-Thin Polyetherimide Foil for Strain Impervious Temperature Sensing
title_full Space-Filling Curve Resistor on Ultra-Thin Polyetherimide Foil for Strain Impervious Temperature Sensing
title_fullStr Space-Filling Curve Resistor on Ultra-Thin Polyetherimide Foil for Strain Impervious Temperature Sensing
title_full_unstemmed Space-Filling Curve Resistor on Ultra-Thin Polyetherimide Foil for Strain Impervious Temperature Sensing
title_short Space-Filling Curve Resistor on Ultra-Thin Polyetherimide Foil for Strain Impervious Temperature Sensing
title_sort space-filling curve resistor on ultra-thin polyetherimide foil for strain impervious temperature sensing
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512779/
https://www.ncbi.nlm.nih.gov/pubmed/34640795
http://dx.doi.org/10.3390/s21196479
work_keys_str_mv AT ragerkorbinian spacefillingcurveresistoronultrathinpolyetherimidefoilforstrainimpervioustemperaturesensing
AT jaworskidavid spacefillingcurveresistoronultrathinpolyetherimidefoilforstrainimpervioustemperaturesensing
AT vonderheidechresten spacefillingcurveresistoronultrathinpolyetherimidefoilforstrainimpervioustemperaturesensing
AT kyriazisalexander spacefillingcurveresistoronultrathinpolyetherimidefoilforstrainimpervioustemperaturesensing
AT sinapiusmichael spacefillingcurveresistoronultrathinpolyetherimidefoilforstrainimpervioustemperaturesensing
AT constantinouiordania spacefillingcurveresistoronultrathinpolyetherimidefoilforstrainimpervioustemperaturesensing
AT dietzelandreas spacefillingcurveresistoronultrathinpolyetherimidefoilforstrainimpervioustemperaturesensing