Cargando…

Capacitively-Coupled ECG and Respiration for Sleep–Wake Prediction and Risk Detection in Sleep Apnea Patients

Obstructive sleep apnea (OSA) patients would strongly benefit from comfortable home diagnosis, during which detection of wakefulness is essential. Therefore, capacitively-coupled electrocardiogram (ccECG) and bioimpedance (ccBioZ) sensors were used to record the sleep of suspected OSA patients, in p...

Descripción completa

Detalles Bibliográficos
Autores principales: Huysmans, Dorien, Castro, Ivan, Borzée, Pascal, Patel, Aakash, Torfs, Tom, Buyse, Bertien, Testelmans, Dries, Van Huffel, Sabine, Varon, Carolina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512805/
https://www.ncbi.nlm.nih.gov/pubmed/34640728
http://dx.doi.org/10.3390/s21196409
Descripción
Sumario:Obstructive sleep apnea (OSA) patients would strongly benefit from comfortable home diagnosis, during which detection of wakefulness is essential. Therefore, capacitively-coupled electrocardiogram (ccECG) and bioimpedance (ccBioZ) sensors were used to record the sleep of suspected OSA patients, in parallel with polysomnography (PSG). The three objectives were quality assessment of the unobtrusive signals during sleep, prediction of sleep–wake using ccECG and ccBioZ, and detection of high-risk OSA patients. First, signal quality indicators (SQIs) determined the data coverage of ccECG and ccBioZ. Then, a multimodal convolutional neural network (CNN) for sleep–wake prediction was tested on these preprocessed ccECG and ccBioZ data. Finally, two indices derived from this prediction detected patients at risk. The data included 187 PSG recordings of suspected OSA patients, 36 (dataset “Test”) of which were recorded simultaneously with PSG, ccECG, and ccBioZ. As a result, two improvements were made compared to prior studies. First, the ccBioZ signal coverage increased significantly due to adaptation of the acquisition system. Secondly, the utility of the sleep–wake classifier increased as it became a unimodal network only requiring respiratory input. This was achieved by using data augmentation during training. Sleep–wake prediction on “Test” using PSG respiration resulted in a Cohen’s kappa ([Formula: see text]) of 0.39 and using ccBioZ in [Formula: see text] = 0.23. The OSA risk model identified severe OSA patients with a [Formula: see text] of 0.61 for PSG respiration and [Formula: see text] of 0.39 using ccBioZ (accuracy of 80.6% and 69.4%, respectively). This study is one of the first to perform sleep–wake staging on capacitively-coupled respiratory signals in suspected OSA patients and to detect high risk OSA patients based on ccBioZ. The technology and the proposed framework could be applied in multi-night follow-up of OSA patients.