Cargando…
Comparison between PtCO(2) and PaCO(2) and Derived Parameters in Heart Failure Patients during Exercise: A Preliminary Study
Evaluation of arterial carbon dioxide pressure (PaCO(2)) and dead space to tidal volume ratio (V(D)/V(T)) during exercise is important for the identification of exercise limitation causes in heart failure (HF). However, repeated sampling of arterial or arterialized ear lobe capillary blood may be cl...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512849/ https://www.ncbi.nlm.nih.gov/pubmed/34640985 http://dx.doi.org/10.3390/s21196666 |
_version_ | 1784583095513513984 |
---|---|
author | Contini, Mauro Angelucci, Alessandra Aliverti, Andrea Gugliandolo, Paola Pezzuto, Beatrice Berna, Giovanni Romani, Simona Tedesco, Calogero Claudio Agostoni, Piergiuseppe |
author_facet | Contini, Mauro Angelucci, Alessandra Aliverti, Andrea Gugliandolo, Paola Pezzuto, Beatrice Berna, Giovanni Romani, Simona Tedesco, Calogero Claudio Agostoni, Piergiuseppe |
author_sort | Contini, Mauro |
collection | PubMed |
description | Evaluation of arterial carbon dioxide pressure (PaCO(2)) and dead space to tidal volume ratio (V(D)/V(T)) during exercise is important for the identification of exercise limitation causes in heart failure (HF). However, repeated sampling of arterial or arterialized ear lobe capillary blood may be clumsy. The aim of our study was to estimate PaCO(2) by means of a non-invasive technique, transcutaneous PCO(2) (PtCO(2)), and to verify the correlation between PtCO(2) and PaCO(2) and between their derived parameters, such as V(D)/V(T), during exercise in HF patients. 29 cardiopulmonary exercise tests (CPET) performed on a bike with a ramp protocol aimed at achieving maximal effort in ≈10 min were analyzed. PaCO(2) and PtCO(2) values were collected at rest and every 2 min during active pedaling. The uncertainty of PCO(2) and V(D)/V(T) measurements were determined by analyzing the error between the two methods. The accuracy of PtCO(2) measurements vs. PaCO(2) decreases towards the end of exercise. Therefore, a correction to PtCO(2) that keeps into account the time of the measurement was implemented with a multiple regression model. PtCO(2) and V(D)/V(T) changes at 6, 8 and 10 min vs. 2 min data were evaluated before and after PtCO(2) correction. PtCO(2) overestimates PaCO(2) for high timestamps (median error 2.45, IQR −0.635–5.405, at 10 min vs. 2 min, p-value = 0.011), while the error is negligible after correction (median error 0.50, IQR = −2.21–3.19, p-value > 0.05). The correction allows removing differences also in PCO(2) and V(D)/V(T) changes. In HF patients PtCO(2) is a reliable PaCO(2) estimation at rest and at low exercise intensity. At high exercise intensity the overall response appears delayed but reproducible and the error can be overcome by mathematical modeling allowing an accurate estimation by PtCO(2) of PaCO(2) and V(D)/V(T). |
format | Online Article Text |
id | pubmed-8512849 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-85128492021-10-14 Comparison between PtCO(2) and PaCO(2) and Derived Parameters in Heart Failure Patients during Exercise: A Preliminary Study Contini, Mauro Angelucci, Alessandra Aliverti, Andrea Gugliandolo, Paola Pezzuto, Beatrice Berna, Giovanni Romani, Simona Tedesco, Calogero Claudio Agostoni, Piergiuseppe Sensors (Basel) Article Evaluation of arterial carbon dioxide pressure (PaCO(2)) and dead space to tidal volume ratio (V(D)/V(T)) during exercise is important for the identification of exercise limitation causes in heart failure (HF). However, repeated sampling of arterial or arterialized ear lobe capillary blood may be clumsy. The aim of our study was to estimate PaCO(2) by means of a non-invasive technique, transcutaneous PCO(2) (PtCO(2)), and to verify the correlation between PtCO(2) and PaCO(2) and between their derived parameters, such as V(D)/V(T), during exercise in HF patients. 29 cardiopulmonary exercise tests (CPET) performed on a bike with a ramp protocol aimed at achieving maximal effort in ≈10 min were analyzed. PaCO(2) and PtCO(2) values were collected at rest and every 2 min during active pedaling. The uncertainty of PCO(2) and V(D)/V(T) measurements were determined by analyzing the error between the two methods. The accuracy of PtCO(2) measurements vs. PaCO(2) decreases towards the end of exercise. Therefore, a correction to PtCO(2) that keeps into account the time of the measurement was implemented with a multiple regression model. PtCO(2) and V(D)/V(T) changes at 6, 8 and 10 min vs. 2 min data were evaluated before and after PtCO(2) correction. PtCO(2) overestimates PaCO(2) for high timestamps (median error 2.45, IQR −0.635–5.405, at 10 min vs. 2 min, p-value = 0.011), while the error is negligible after correction (median error 0.50, IQR = −2.21–3.19, p-value > 0.05). The correction allows removing differences also in PCO(2) and V(D)/V(T) changes. In HF patients PtCO(2) is a reliable PaCO(2) estimation at rest and at low exercise intensity. At high exercise intensity the overall response appears delayed but reproducible and the error can be overcome by mathematical modeling allowing an accurate estimation by PtCO(2) of PaCO(2) and V(D)/V(T). MDPI 2021-10-07 /pmc/articles/PMC8512849/ /pubmed/34640985 http://dx.doi.org/10.3390/s21196666 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Contini, Mauro Angelucci, Alessandra Aliverti, Andrea Gugliandolo, Paola Pezzuto, Beatrice Berna, Giovanni Romani, Simona Tedesco, Calogero Claudio Agostoni, Piergiuseppe Comparison between PtCO(2) and PaCO(2) and Derived Parameters in Heart Failure Patients during Exercise: A Preliminary Study |
title | Comparison between PtCO(2) and PaCO(2) and Derived Parameters in Heart Failure Patients during Exercise: A Preliminary Study |
title_full | Comparison between PtCO(2) and PaCO(2) and Derived Parameters in Heart Failure Patients during Exercise: A Preliminary Study |
title_fullStr | Comparison between PtCO(2) and PaCO(2) and Derived Parameters in Heart Failure Patients during Exercise: A Preliminary Study |
title_full_unstemmed | Comparison between PtCO(2) and PaCO(2) and Derived Parameters in Heart Failure Patients during Exercise: A Preliminary Study |
title_short | Comparison between PtCO(2) and PaCO(2) and Derived Parameters in Heart Failure Patients during Exercise: A Preliminary Study |
title_sort | comparison between ptco(2) and paco(2) and derived parameters in heart failure patients during exercise: a preliminary study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8512849/ https://www.ncbi.nlm.nih.gov/pubmed/34640985 http://dx.doi.org/10.3390/s21196666 |
work_keys_str_mv | AT continimauro comparisonbetweenptco2andpaco2andderivedparametersinheartfailurepatientsduringexerciseapreliminarystudy AT angeluccialessandra comparisonbetweenptco2andpaco2andderivedparametersinheartfailurepatientsduringexerciseapreliminarystudy AT alivertiandrea comparisonbetweenptco2andpaco2andderivedparametersinheartfailurepatientsduringexerciseapreliminarystudy AT gugliandolopaola comparisonbetweenptco2andpaco2andderivedparametersinheartfailurepatientsduringexerciseapreliminarystudy AT pezzutobeatrice comparisonbetweenptco2andpaco2andderivedparametersinheartfailurepatientsduringexerciseapreliminarystudy AT bernagiovanni comparisonbetweenptco2andpaco2andderivedparametersinheartfailurepatientsduringexerciseapreliminarystudy AT romanisimona comparisonbetweenptco2andpaco2andderivedparametersinheartfailurepatientsduringexerciseapreliminarystudy AT tedescocalogeroclaudio comparisonbetweenptco2andpaco2andderivedparametersinheartfailurepatientsduringexerciseapreliminarystudy AT agostonipiergiuseppe comparisonbetweenptco2andpaco2andderivedparametersinheartfailurepatientsduringexerciseapreliminarystudy |