Cargando…
Quality of life: modified triple-branched stent graft implantation versus frozen elephant trunk technique
OBJECTIVE: To compare the effects of modified triple-branched stent implantation and frozen elephant trunk technique on the quality of life (QoL) of acute Stanford Type A aortic dissection (AAAD) patients at different follow-up times. METHODS: Data from 175 AAAD survivors was collected which were di...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8513261/ https://www.ncbi.nlm.nih.gov/pubmed/34645494 http://dx.doi.org/10.1186/s13019-021-01683-9 |
_version_ | 1784583177020375040 |
---|---|
author | Luo, Zeng-Rong Tang, Mi-Rong Li, Jia-Hui Chen, Liang-Wan Yan, Liang-Liang |
author_facet | Luo, Zeng-Rong Tang, Mi-Rong Li, Jia-Hui Chen, Liang-Wan Yan, Liang-Liang |
author_sort | Luo, Zeng-Rong |
collection | PubMed |
description | OBJECTIVE: To compare the effects of modified triple-branched stent implantation and frozen elephant trunk technique on the quality of life (QoL) of acute Stanford Type A aortic dissection (AAAD) patients at different follow-up times. METHODS: Data from 175 AAAD survivors was collected which were divided into two groups according to different surgical techniques: (group A): modified triple-branched stent graft implantation; (group B): frozen elephant trunk. The SF-36 were used to assess the QoL at discharge (AD), the third postoperative month (POM3), and the twelfth postoperative month (POM12). RESULTS: (1) The total scores at each time of both groups showed lower than the normal level; Group A scored higher than group B at some time points in terms of some items (role physical, role emotion and mental health; all P = 0.000), and some items at POM3 or POM12 scored higher than at discharge (role physical, social function; both P = 0.000). (2) There were less patients with heavy self-perceived burden in group A than group B at discharge (P = 0.032) and patients with heavy self-perceived burden decreased over time. (3) Young postoperative AAD patients (P = 0.002) in group B (P = 0.005) with heavy self-perceived burden (P = 0.000), acute renal failure (P = 0.008), long LOS (P = 0.026) and blood loss (> 1000 mL/24 h) (P = 0.039) seemed to get a worse QoL. CONCLUSION: The impact on QoL of the modified triple-branched stent graft implantation technique seemed to be better than those of frozen elephant trunk surgery in role physical, role emotion and mental health. |
format | Online Article Text |
id | pubmed-8513261 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-85132612021-10-20 Quality of life: modified triple-branched stent graft implantation versus frozen elephant trunk technique Luo, Zeng-Rong Tang, Mi-Rong Li, Jia-Hui Chen, Liang-Wan Yan, Liang-Liang J Cardiothorac Surg Research Article OBJECTIVE: To compare the effects of modified triple-branched stent implantation and frozen elephant trunk technique on the quality of life (QoL) of acute Stanford Type A aortic dissection (AAAD) patients at different follow-up times. METHODS: Data from 175 AAAD survivors was collected which were divided into two groups according to different surgical techniques: (group A): modified triple-branched stent graft implantation; (group B): frozen elephant trunk. The SF-36 were used to assess the QoL at discharge (AD), the third postoperative month (POM3), and the twelfth postoperative month (POM12). RESULTS: (1) The total scores at each time of both groups showed lower than the normal level; Group A scored higher than group B at some time points in terms of some items (role physical, role emotion and mental health; all P = 0.000), and some items at POM3 or POM12 scored higher than at discharge (role physical, social function; both P = 0.000). (2) There were less patients with heavy self-perceived burden in group A than group B at discharge (P = 0.032) and patients with heavy self-perceived burden decreased over time. (3) Young postoperative AAD patients (P = 0.002) in group B (P = 0.005) with heavy self-perceived burden (P = 0.000), acute renal failure (P = 0.008), long LOS (P = 0.026) and blood loss (> 1000 mL/24 h) (P = 0.039) seemed to get a worse QoL. CONCLUSION: The impact on QoL of the modified triple-branched stent graft implantation technique seemed to be better than those of frozen elephant trunk surgery in role physical, role emotion and mental health. BioMed Central 2021-10-13 /pmc/articles/PMC8513261/ /pubmed/34645494 http://dx.doi.org/10.1186/s13019-021-01683-9 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Luo, Zeng-Rong Tang, Mi-Rong Li, Jia-Hui Chen, Liang-Wan Yan, Liang-Liang Quality of life: modified triple-branched stent graft implantation versus frozen elephant trunk technique |
title | Quality of life: modified triple-branched stent graft implantation versus frozen elephant trunk technique |
title_full | Quality of life: modified triple-branched stent graft implantation versus frozen elephant trunk technique |
title_fullStr | Quality of life: modified triple-branched stent graft implantation versus frozen elephant trunk technique |
title_full_unstemmed | Quality of life: modified triple-branched stent graft implantation versus frozen elephant trunk technique |
title_short | Quality of life: modified triple-branched stent graft implantation versus frozen elephant trunk technique |
title_sort | quality of life: modified triple-branched stent graft implantation versus frozen elephant trunk technique |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8513261/ https://www.ncbi.nlm.nih.gov/pubmed/34645494 http://dx.doi.org/10.1186/s13019-021-01683-9 |
work_keys_str_mv | AT luozengrong qualityoflifemodifiedtriplebranchedstentgraftimplantationversusfrozenelephanttrunktechnique AT tangmirong qualityoflifemodifiedtriplebranchedstentgraftimplantationversusfrozenelephanttrunktechnique AT lijiahui qualityoflifemodifiedtriplebranchedstentgraftimplantationversusfrozenelephanttrunktechnique AT chenliangwan qualityoflifemodifiedtriplebranchedstentgraftimplantationversusfrozenelephanttrunktechnique AT yanliangliang qualityoflifemodifiedtriplebranchedstentgraftimplantationversusfrozenelephanttrunktechnique |