Cargando…

Assessing the Suitability of Next-Generation Viral Outgrowth Assays to Measure Human Immunodeficiency Virus 1 Latent Reservoir Size

BACKGROUND: Evaluations of human immunodeficiency virus (HIV) curative interventions require reliable and efficient quantification of replication-competent latent reservoirs. The “classic” quantitative viral outgrowth assay (QVOA) has been regarded as the reference standard, although prohibitively r...

Descripción completa

Detalles Bibliográficos
Autores principales: Stone, Mars, Rosenbloom, Daniel I S, Bacchetti, Peter, Deng, Xutao, Dimapasoc, Melanie, Keating, Sheila, Bakkour, Sonia, Richman, Douglas D, Mellors, John W, Deeks, Steven G, Lai, Jun, Beg, Subul, Siliciano, Janet D, Pagliuzza, Amélie, Chomont, Nicolas, Lackman-Smith, Carol, Ptak, Roger G, Busch, Michael P
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8514180/
https://www.ncbi.nlm.nih.gov/pubmed/32147687
http://dx.doi.org/10.1093/infdis/jiaa089
Descripción
Sumario:BACKGROUND: Evaluations of human immunodeficiency virus (HIV) curative interventions require reliable and efficient quantification of replication-competent latent reservoirs. The “classic” quantitative viral outgrowth assay (QVOA) has been regarded as the reference standard, although prohibitively resource and labor intensive. We compared 6 “next-generation” viral outgrowth assays, using polymerase chain reaction or ultrasensitive p24 to assess their suitability as scalable proxies for QVOA. METHODS: Next-generation QVOAs were compared with classic QVOA using single leukapheresis-derived samples from 5 antiretroviral therapy–suppressed HIV-infected participants and 1 HIV-uninfected control; each laboratory tested blinded batches of 3 frozen and 1 fresh sample. Markov chain Monte Carlo methods estimated extra-Poisson variation at aliquot, batch, and laboratory levels. Models also estimated the effect of testing frozen versus fresh samples. RESULTS: Next-generation QVOAs had similar estimates of variation to QVOA. Assays with ultrasensitive readout reported higher infectious units per million values than classic QVOA. Within-batch testing had 2.5-fold extra-Poisson variation (95% credible interval [CI], 2.1–3.5-fold) for next-generation assays. Between-laboratory variation increased extra-Poisson variation to 3.4-fold (95% CI, 2.6–5.4-fold). Frozen storage did not substantially alter infectious units per million values (−18%; 95% CI, −52% to 39%). CONCLUSIONS: The data offer cautious support for use of next-generation QVOAs as proxies for more laborious QVOA, while providing greater sensitivities and dynamic ranges. Measurement of latent reservoirs in eradication strategies would benefit from high throughput and scalable assays.