Cargando…

A Method for Expanding Mass Range on a Multi-Turn Time-of-Flight Mass Spectrometer by a Lap Superimposed Spectrum

A time-of-flight mass spectrometer that uses a closed-orbit flight path can achieve a high mass resolving power and a high mass accuracy with a small instrument footprint. It has long been known that a drawback to a closed flight path is an obtained spectrum may contain peaks by ions at a different...

Descripción completa

Detalles Bibliográficos
Autores principales: Hondo, Toshinobu, Toyoda, Michisato
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Mass Spectrometry Society of Japan 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8514288/
https://www.ncbi.nlm.nih.gov/pubmed/34703719
http://dx.doi.org/10.5702/massspectrometry.A0098
_version_ 1784583354800144384
author Hondo, Toshinobu
Toyoda, Michisato
author_facet Hondo, Toshinobu
Toyoda, Michisato
author_sort Hondo, Toshinobu
collection PubMed
description A time-of-flight mass spectrometer that uses a closed-orbit flight path can achieve a high mass resolving power and a high mass accuracy with a small instrument footprint. It has long been known that a drawback to a closed flight path is an obtained spectrum may contain peaks by ions at a different number of laps. A lower m/z ion may overtake higher m/z ions, resulting in the peak being superimposed on an acquired mass spectrum; therefore, such a mass bandwidth of the analyzer is limited to a narrow range given the current situation. However, recent research has documented a solution to the problem based on careful study of the equation of motion of an ion in a closed-path analyzer. All of the ions in the analyzer remain in motion in orbit by the nature of the closed flight path, thus resulting in a superimposed spectrum with the width of the orbital period of the highest mass in the sample matrix, which contains several different lap numbers. When target ions for the sample are known in advance, the time-of-flight for a given m/z can be determined regardless of the lap number under given analyzer conditions, and peak assignment can be self-validated by comparison to a mass spectrum acquired at a different lap condition. Furthermore, the m/z value for an unknown ion can also be determined by comparing time-of-flight values on spectra acquired at different lap conditions.
format Online
Article
Text
id pubmed-8514288
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Mass Spectrometry Society of Japan
record_format MEDLINE/PubMed
spelling pubmed-85142882021-10-25 A Method for Expanding Mass Range on a Multi-Turn Time-of-Flight Mass Spectrometer by a Lap Superimposed Spectrum Hondo, Toshinobu Toyoda, Michisato Mass Spectrom (Tokyo) Technical Report A time-of-flight mass spectrometer that uses a closed-orbit flight path can achieve a high mass resolving power and a high mass accuracy with a small instrument footprint. It has long been known that a drawback to a closed flight path is an obtained spectrum may contain peaks by ions at a different number of laps. A lower m/z ion may overtake higher m/z ions, resulting in the peak being superimposed on an acquired mass spectrum; therefore, such a mass bandwidth of the analyzer is limited to a narrow range given the current situation. However, recent research has documented a solution to the problem based on careful study of the equation of motion of an ion in a closed-path analyzer. All of the ions in the analyzer remain in motion in orbit by the nature of the closed flight path, thus resulting in a superimposed spectrum with the width of the orbital period of the highest mass in the sample matrix, which contains several different lap numbers. When target ions for the sample are known in advance, the time-of-flight for a given m/z can be determined regardless of the lap number under given analyzer conditions, and peak assignment can be self-validated by comparison to a mass spectrum acquired at a different lap condition. Furthermore, the m/z value for an unknown ion can also be determined by comparing time-of-flight values on spectra acquired at different lap conditions. The Mass Spectrometry Society of Japan 2021 2021-10-14 /pmc/articles/PMC8514288/ /pubmed/34703719 http://dx.doi.org/10.5702/massspectrometry.A0098 Text en Copyright © 2021 Toshinobu Hondo and Michisato Toyoda. https://creativecommons.org/licenses/by/2.5/This is an open-access article distributed under the terms of Creative Commons Attribution Non-Commercial 4.0 International License, which permits use, distribution, and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Technical Report
Hondo, Toshinobu
Toyoda, Michisato
A Method for Expanding Mass Range on a Multi-Turn Time-of-Flight Mass Spectrometer by a Lap Superimposed Spectrum
title A Method for Expanding Mass Range on a Multi-Turn Time-of-Flight Mass Spectrometer by a Lap Superimposed Spectrum
title_full A Method for Expanding Mass Range on a Multi-Turn Time-of-Flight Mass Spectrometer by a Lap Superimposed Spectrum
title_fullStr A Method for Expanding Mass Range on a Multi-Turn Time-of-Flight Mass Spectrometer by a Lap Superimposed Spectrum
title_full_unstemmed A Method for Expanding Mass Range on a Multi-Turn Time-of-Flight Mass Spectrometer by a Lap Superimposed Spectrum
title_short A Method for Expanding Mass Range on a Multi-Turn Time-of-Flight Mass Spectrometer by a Lap Superimposed Spectrum
title_sort method for expanding mass range on a multi-turn time-of-flight mass spectrometer by a lap superimposed spectrum
topic Technical Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8514288/
https://www.ncbi.nlm.nih.gov/pubmed/34703719
http://dx.doi.org/10.5702/massspectrometry.A0098
work_keys_str_mv AT hondotoshinobu amethodforexpandingmassrangeonamultiturntimeofflightmassspectrometerbyalapsuperimposedspectrum
AT toyodamichisato amethodforexpandingmassrangeonamultiturntimeofflightmassspectrometerbyalapsuperimposedspectrum
AT hondotoshinobu methodforexpandingmassrangeonamultiturntimeofflightmassspectrometerbyalapsuperimposedspectrum
AT toyodamichisato methodforexpandingmassrangeonamultiturntimeofflightmassspectrometerbyalapsuperimposedspectrum