Combined endovascular and open treatment to prevent increase in afterload in anastomotic pseudoaneurysm and aortobronchial fistula after surgery for aortic coarctation

We report the treatment of a patient who had presented with hemoptysis due to an aortobronchial fistula from an anastomotic pseudoaneurysm after extra-anatomic bypass for aortic coarctation. An aortobronchial fistula can often result from an aortic pseudoaneurysm and is associated with high mortalit...

Descripción completa

Detalles Bibliográficos
Autores principales: Nodari, Franco, Verrengia, Apollonia, Di Betta, Ernesto, Bonera, Giulia, Bonardelli, Stefano
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8515165/
https://www.ncbi.nlm.nih.gov/pubmed/34693088
http://dx.doi.org/10.1016/j.jvscit.2021.08.001
_version_ 1784583560142782464
author Nodari, Franco
Verrengia, Apollonia
Di Betta, Ernesto
Bonera, Giulia
Bonardelli, Stefano
author_facet Nodari, Franco
Verrengia, Apollonia
Di Betta, Ernesto
Bonera, Giulia
Bonardelli, Stefano
author_sort Nodari, Franco
collection PubMed
description We report the treatment of a patient who had presented with hemoptysis due to an aortobronchial fistula from an anastomotic pseudoaneurysm after extra-anatomic bypass for aortic coarctation. An aortobronchial fistula can often result from an aortic pseudoaneurysm and is associated with high mortality if not treated. We decided to use combined endovascular and open surgical treatment and obtained a satisfactory intraoperative result. The perioperative outcome and first follow-up visit were favorable. In recent years, endovascular repair of pathologic aortic conditions has increased; thus, we have placed the present case within the context of the relevant medical literature.
format Online
Article
Text
id pubmed-8515165
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-85151652021-10-21 Combined endovascular and open treatment to prevent increase in afterload in anastomotic pseudoaneurysm and aortobronchial fistula after surgery for aortic coarctation Nodari, Franco Verrengia, Apollonia Di Betta, Ernesto Bonera, Giulia Bonardelli, Stefano J Vasc Surg Cases Innov Tech Case report We report the treatment of a patient who had presented with hemoptysis due to an aortobronchial fistula from an anastomotic pseudoaneurysm after extra-anatomic bypass for aortic coarctation. An aortobronchial fistula can often result from an aortic pseudoaneurysm and is associated with high mortality if not treated. We decided to use combined endovascular and open surgical treatment and obtained a satisfactory intraoperative result. The perioperative outcome and first follow-up visit were favorable. In recent years, endovascular repair of pathologic aortic conditions has increased; thus, we have placed the present case within the context of the relevant medical literature. Elsevier 2021-09-15 /pmc/articles/PMC8515165/ /pubmed/34693088 http://dx.doi.org/10.1016/j.jvscit.2021.08.001 Text en © 2021 Published by Elsevier Inc. on behalf of Society for Vascular Surgery. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case report
Nodari, Franco
Verrengia, Apollonia
Di Betta, Ernesto
Bonera, Giulia
Bonardelli, Stefano
Combined endovascular and open treatment to prevent increase in afterload in anastomotic pseudoaneurysm and aortobronchial fistula after surgery for aortic coarctation
title Combined endovascular and open treatment to prevent increase in afterload in anastomotic pseudoaneurysm and aortobronchial fistula after surgery for aortic coarctation
title_full Combined endovascular and open treatment to prevent increase in afterload in anastomotic pseudoaneurysm and aortobronchial fistula after surgery for aortic coarctation
title_fullStr Combined endovascular and open treatment to prevent increase in afterload in anastomotic pseudoaneurysm and aortobronchial fistula after surgery for aortic coarctation
title_full_unstemmed Combined endovascular and open treatment to prevent increase in afterload in anastomotic pseudoaneurysm and aortobronchial fistula after surgery for aortic coarctation
title_short Combined endovascular and open treatment to prevent increase in afterload in anastomotic pseudoaneurysm and aortobronchial fistula after surgery for aortic coarctation
title_sort combined endovascular and open treatment to prevent increase in afterload in anastomotic pseudoaneurysm and aortobronchial fistula after surgery for aortic coarctation
topic Case report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8515165/
https://www.ncbi.nlm.nih.gov/pubmed/34693088
http://dx.doi.org/10.1016/j.jvscit.2021.08.001
work_keys_str_mv AT nodarifranco combinedendovascularandopentreatmenttopreventincreaseinafterloadinanastomoticpseudoaneurysmandaortobronchialfistulaaftersurgeryforaorticcoarctation
AT verrengiaapollonia combinedendovascularandopentreatmenttopreventincreaseinafterloadinanastomoticpseudoaneurysmandaortobronchialfistulaaftersurgeryforaorticcoarctation
AT dibettaernesto combinedendovascularandopentreatmenttopreventincreaseinafterloadinanastomoticpseudoaneurysmandaortobronchialfistulaaftersurgeryforaorticcoarctation
AT boneragiulia combinedendovascularandopentreatmenttopreventincreaseinafterloadinanastomoticpseudoaneurysmandaortobronchialfistulaaftersurgeryforaorticcoarctation
AT bonardellistefano combinedendovascularandopentreatmenttopreventincreaseinafterloadinanastomoticpseudoaneurysmandaortobronchialfistulaaftersurgeryforaorticcoarctation