Combined endovascular and open treatment to prevent increase in afterload in anastomotic pseudoaneurysm and aortobronchial fistula after surgery for aortic coarctation

We report the treatment of a patient who had presented with hemoptysis due to an aortobronchial fistula from an anastomotic pseudoaneurysm after extra-anatomic bypass for aortic coarctation. An aortobronchial fistula can often result from an aortic pseudoaneurysm and is associated with high mortalit...