The biomechanical effect of the relevant segments after facet-disectomy in different diameters under posterior lumbar percutaneous endoscopes: a three-dimensional finite element analysis
OBJECTIVE: To evaluate the biomechanical influence after percutaneous endoscopic lumbar facetectomy in different diameters on segmental range of motion (ROM) and intradiscal pressure (IDP) of the relevant segments by establishing three dimensional finite element (FE) model. METHODS: An intact L3–5 m...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8515756/ https://www.ncbi.nlm.nih.gov/pubmed/34649582 http://dx.doi.org/10.1186/s13018-021-02733-7 |
_version_ | 1784583676704587776 |
---|---|
author | Shi, Yin Xie, Yi-Zhou Zhou, Qun Yu, Yang Fan, Xiao-Hong |
author_facet | Shi, Yin Xie, Yi-Zhou Zhou, Qun Yu, Yang Fan, Xiao-Hong |
author_sort | Shi, Yin |
collection | PubMed |
description | OBJECTIVE: To evaluate the biomechanical influence after percutaneous endoscopic lumbar facetectomy in different diameters on segmental range of motion (ROM) and intradiscal pressure (IDP) of the relevant segments by establishing three dimensional finite element (FE) model. METHODS: An intact L3–5 model was successfully constructed from the CT of a healthy volunteer as Model A (MA). The Model B (MB), Model C (MC) and Model D (MD) were obtained through facetectomy on L4 inferior facet in diameters 7.5 mm, 10 mm and 15 mm on MA for simulation. The ROM and IDP of L3/4 and L4/5 of four models were all compared in forward flexion, backward extension, left and right bending, left and right rotation. RESULTS: Compared with MA, the ROM of L4/5 of MB, MC and MD all increased. MD changed more significantly than MB and MC in backward extension, right bending and right rotation. But that of MB and MC on L3/4 had no prominent change, while MD had a slight increase in backward extension. The IDP of MB and MC on L4/5 in six states was similar to MA, yet MD increased obviously in backward extension, right bending, left and right rotation. The IDP on L3/4 of MB and MC was resemble to MA in six conditions, nevertheless MD increased slightly only in backward extension. CONCLUSION: Compared with the facetectomy in diameters 7.5 mm and 10 mm, the mechanical effect brought by facetectomy in diameter 15 mm on the operating segment changed more significantly, and had a corresponding effect on the adjacent segments. |
format | Online Article Text |
id | pubmed-8515756 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-85157562021-10-20 The biomechanical effect of the relevant segments after facet-disectomy in different diameters under posterior lumbar percutaneous endoscopes: a three-dimensional finite element analysis Shi, Yin Xie, Yi-Zhou Zhou, Qun Yu, Yang Fan, Xiao-Hong J Orthop Surg Res Research Article OBJECTIVE: To evaluate the biomechanical influence after percutaneous endoscopic lumbar facetectomy in different diameters on segmental range of motion (ROM) and intradiscal pressure (IDP) of the relevant segments by establishing three dimensional finite element (FE) model. METHODS: An intact L3–5 model was successfully constructed from the CT of a healthy volunteer as Model A (MA). The Model B (MB), Model C (MC) and Model D (MD) were obtained through facetectomy on L4 inferior facet in diameters 7.5 mm, 10 mm and 15 mm on MA for simulation. The ROM and IDP of L3/4 and L4/5 of four models were all compared in forward flexion, backward extension, left and right bending, left and right rotation. RESULTS: Compared with MA, the ROM of L4/5 of MB, MC and MD all increased. MD changed more significantly than MB and MC in backward extension, right bending and right rotation. But that of MB and MC on L3/4 had no prominent change, while MD had a slight increase in backward extension. The IDP of MB and MC on L4/5 in six states was similar to MA, yet MD increased obviously in backward extension, right bending, left and right rotation. The IDP on L3/4 of MB and MC was resemble to MA in six conditions, nevertheless MD increased slightly only in backward extension. CONCLUSION: Compared with the facetectomy in diameters 7.5 mm and 10 mm, the mechanical effect brought by facetectomy in diameter 15 mm on the operating segment changed more significantly, and had a corresponding effect on the adjacent segments. BioMed Central 2021-10-14 /pmc/articles/PMC8515756/ /pubmed/34649582 http://dx.doi.org/10.1186/s13018-021-02733-7 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Shi, Yin Xie, Yi-Zhou Zhou, Qun Yu, Yang Fan, Xiao-Hong The biomechanical effect of the relevant segments after facet-disectomy in different diameters under posterior lumbar percutaneous endoscopes: a three-dimensional finite element analysis |
title | The biomechanical effect of the relevant segments after facet-disectomy in different diameters under posterior lumbar percutaneous endoscopes: a three-dimensional finite element analysis |
title_full | The biomechanical effect of the relevant segments after facet-disectomy in different diameters under posterior lumbar percutaneous endoscopes: a three-dimensional finite element analysis |
title_fullStr | The biomechanical effect of the relevant segments after facet-disectomy in different diameters under posterior lumbar percutaneous endoscopes: a three-dimensional finite element analysis |
title_full_unstemmed | The biomechanical effect of the relevant segments after facet-disectomy in different diameters under posterior lumbar percutaneous endoscopes: a three-dimensional finite element analysis |
title_short | The biomechanical effect of the relevant segments after facet-disectomy in different diameters under posterior lumbar percutaneous endoscopes: a three-dimensional finite element analysis |
title_sort | biomechanical effect of the relevant segments after facet-disectomy in different diameters under posterior lumbar percutaneous endoscopes: a three-dimensional finite element analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8515756/ https://www.ncbi.nlm.nih.gov/pubmed/34649582 http://dx.doi.org/10.1186/s13018-021-02733-7 |
work_keys_str_mv | AT shiyin thebiomechanicaleffectoftherelevantsegmentsafterfacetdisectomyindifferentdiametersunderposteriorlumbarpercutaneousendoscopesathreedimensionalfiniteelementanalysis AT xieyizhou thebiomechanicaleffectoftherelevantsegmentsafterfacetdisectomyindifferentdiametersunderposteriorlumbarpercutaneousendoscopesathreedimensionalfiniteelementanalysis AT zhouqun thebiomechanicaleffectoftherelevantsegmentsafterfacetdisectomyindifferentdiametersunderposteriorlumbarpercutaneousendoscopesathreedimensionalfiniteelementanalysis AT yuyang thebiomechanicaleffectoftherelevantsegmentsafterfacetdisectomyindifferentdiametersunderposteriorlumbarpercutaneousendoscopesathreedimensionalfiniteelementanalysis AT fanxiaohong thebiomechanicaleffectoftherelevantsegmentsafterfacetdisectomyindifferentdiametersunderposteriorlumbarpercutaneousendoscopesathreedimensionalfiniteelementanalysis AT shiyin biomechanicaleffectoftherelevantsegmentsafterfacetdisectomyindifferentdiametersunderposteriorlumbarpercutaneousendoscopesathreedimensionalfiniteelementanalysis AT xieyizhou biomechanicaleffectoftherelevantsegmentsafterfacetdisectomyindifferentdiametersunderposteriorlumbarpercutaneousendoscopesathreedimensionalfiniteelementanalysis AT zhouqun biomechanicaleffectoftherelevantsegmentsafterfacetdisectomyindifferentdiametersunderposteriorlumbarpercutaneousendoscopesathreedimensionalfiniteelementanalysis AT yuyang biomechanicaleffectoftherelevantsegmentsafterfacetdisectomyindifferentdiametersunderposteriorlumbarpercutaneousendoscopesathreedimensionalfiniteelementanalysis AT fanxiaohong biomechanicaleffectoftherelevantsegmentsafterfacetdisectomyindifferentdiametersunderposteriorlumbarpercutaneousendoscopesathreedimensionalfiniteelementanalysis |