Cargando…
Artificial intelligence on COVID-19 pneumonia detection using chest xray images
Recent studies show the potential of artificial intelligence (AI) as a screening tool to detect COVID-19 pneumonia based on chest x-ray (CXR) images. However, issues on the datasets and study designs from medical and technical perspectives, as well as questions on the vulnerability and robustness of...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8516252/ https://www.ncbi.nlm.nih.gov/pubmed/34648509 http://dx.doi.org/10.1371/journal.pone.0257884 |
_version_ | 1784583760063234048 |
---|---|
author | Baltazar, Lei Rigi Manzanillo, Mojhune Gabriel Gaudillo, Joverlyn Viray, Ethel Dominique Domingo, Mario Tiangco, Beatrice Albia, Jason |
author_facet | Baltazar, Lei Rigi Manzanillo, Mojhune Gabriel Gaudillo, Joverlyn Viray, Ethel Dominique Domingo, Mario Tiangco, Beatrice Albia, Jason |
author_sort | Baltazar, Lei Rigi |
collection | PubMed |
description | Recent studies show the potential of artificial intelligence (AI) as a screening tool to detect COVID-19 pneumonia based on chest x-ray (CXR) images. However, issues on the datasets and study designs from medical and technical perspectives, as well as questions on the vulnerability and robustness of AI algorithms have emerged. In this study, we address these issues with a more realistic development of AI-driven COVID-19 pneumonia detection models by generating our own data through a retrospective clinical study to augment the dataset aggregated from external sources. We optimized five deep learning architectures, implemented development strategies by manipulating data distribution to quantitatively compare study designs, and introduced several detection scenarios to evaluate the robustness and diagnostic performance of the models. At the current level of data availability, the performance of the detection model depends on the hyperparameter tuning and has less dependency on the quantity of data. InceptionV3 attained the highest performance in distinguishing pneumonia from normal CXR in two-class detection scenario with sensitivity (Sn), specificity (Sp), and positive predictive value (PPV) of 96%. The models attained higher general performance of 91-96% Sn, 94-98% Sp, and 90-96% PPV in three-class compared to four-class detection scenario. InceptionV3 has the highest general performance with accuracy, F1-score, and g-mean of 96% in the three-class detection scenario. For COVID-19 pneumonia detection, InceptionV3 attained the highest performance with 86% Sn, 99% Sp, and 91% PPV with an AUC of 0.99 in distinguishing pneumonia from normal CXR. Its capability of differentiating COVID-19 pneumonia from normal and non-COVID-19 pneumonia attained 0.98 AUC and a micro-average of 0.99 for other classes. |
format | Online Article Text |
id | pubmed-8516252 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-85162522021-10-15 Artificial intelligence on COVID-19 pneumonia detection using chest xray images Baltazar, Lei Rigi Manzanillo, Mojhune Gabriel Gaudillo, Joverlyn Viray, Ethel Dominique Domingo, Mario Tiangco, Beatrice Albia, Jason PLoS One Research Article Recent studies show the potential of artificial intelligence (AI) as a screening tool to detect COVID-19 pneumonia based on chest x-ray (CXR) images. However, issues on the datasets and study designs from medical and technical perspectives, as well as questions on the vulnerability and robustness of AI algorithms have emerged. In this study, we address these issues with a more realistic development of AI-driven COVID-19 pneumonia detection models by generating our own data through a retrospective clinical study to augment the dataset aggregated from external sources. We optimized five deep learning architectures, implemented development strategies by manipulating data distribution to quantitatively compare study designs, and introduced several detection scenarios to evaluate the robustness and diagnostic performance of the models. At the current level of data availability, the performance of the detection model depends on the hyperparameter tuning and has less dependency on the quantity of data. InceptionV3 attained the highest performance in distinguishing pneumonia from normal CXR in two-class detection scenario with sensitivity (Sn), specificity (Sp), and positive predictive value (PPV) of 96%. The models attained higher general performance of 91-96% Sn, 94-98% Sp, and 90-96% PPV in three-class compared to four-class detection scenario. InceptionV3 has the highest general performance with accuracy, F1-score, and g-mean of 96% in the three-class detection scenario. For COVID-19 pneumonia detection, InceptionV3 attained the highest performance with 86% Sn, 99% Sp, and 91% PPV with an AUC of 0.99 in distinguishing pneumonia from normal CXR. Its capability of differentiating COVID-19 pneumonia from normal and non-COVID-19 pneumonia attained 0.98 AUC and a micro-average of 0.99 for other classes. Public Library of Science 2021-10-14 /pmc/articles/PMC8516252/ /pubmed/34648509 http://dx.doi.org/10.1371/journal.pone.0257884 Text en © 2021 Baltazar et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Baltazar, Lei Rigi Manzanillo, Mojhune Gabriel Gaudillo, Joverlyn Viray, Ethel Dominique Domingo, Mario Tiangco, Beatrice Albia, Jason Artificial intelligence on COVID-19 pneumonia detection using chest xray images |
title | Artificial intelligence on COVID-19 pneumonia detection using chest xray images |
title_full | Artificial intelligence on COVID-19 pneumonia detection using chest xray images |
title_fullStr | Artificial intelligence on COVID-19 pneumonia detection using chest xray images |
title_full_unstemmed | Artificial intelligence on COVID-19 pneumonia detection using chest xray images |
title_short | Artificial intelligence on COVID-19 pneumonia detection using chest xray images |
title_sort | artificial intelligence on covid-19 pneumonia detection using chest xray images |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8516252/ https://www.ncbi.nlm.nih.gov/pubmed/34648509 http://dx.doi.org/10.1371/journal.pone.0257884 |
work_keys_str_mv | AT baltazarleirigi artificialintelligenceoncovid19pneumoniadetectionusingchestxrayimages AT manzanillomojhunegabriel artificialintelligenceoncovid19pneumoniadetectionusingchestxrayimages AT gaudillojoverlyn artificialintelligenceoncovid19pneumoniadetectionusingchestxrayimages AT virayetheldominique artificialintelligenceoncovid19pneumoniadetectionusingchestxrayimages AT domingomario artificialintelligenceoncovid19pneumoniadetectionusingchestxrayimages AT tiangcobeatrice artificialintelligenceoncovid19pneumoniadetectionusingchestxrayimages AT albiajason artificialintelligenceoncovid19pneumoniadetectionusingchestxrayimages |