Cargando…

Artificial intelligence on COVID-19 pneumonia detection using chest xray images

Recent studies show the potential of artificial intelligence (AI) as a screening tool to detect COVID-19 pneumonia based on chest x-ray (CXR) images. However, issues on the datasets and study designs from medical and technical perspectives, as well as questions on the vulnerability and robustness of...

Descripción completa

Detalles Bibliográficos
Autores principales: Baltazar, Lei Rigi, Manzanillo, Mojhune Gabriel, Gaudillo, Joverlyn, Viray, Ethel Dominique, Domingo, Mario, Tiangco, Beatrice, Albia, Jason
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8516252/
https://www.ncbi.nlm.nih.gov/pubmed/34648509
http://dx.doi.org/10.1371/journal.pone.0257884
_version_ 1784583760063234048
author Baltazar, Lei Rigi
Manzanillo, Mojhune Gabriel
Gaudillo, Joverlyn
Viray, Ethel Dominique
Domingo, Mario
Tiangco, Beatrice
Albia, Jason
author_facet Baltazar, Lei Rigi
Manzanillo, Mojhune Gabriel
Gaudillo, Joverlyn
Viray, Ethel Dominique
Domingo, Mario
Tiangco, Beatrice
Albia, Jason
author_sort Baltazar, Lei Rigi
collection PubMed
description Recent studies show the potential of artificial intelligence (AI) as a screening tool to detect COVID-19 pneumonia based on chest x-ray (CXR) images. However, issues on the datasets and study designs from medical and technical perspectives, as well as questions on the vulnerability and robustness of AI algorithms have emerged. In this study, we address these issues with a more realistic development of AI-driven COVID-19 pneumonia detection models by generating our own data through a retrospective clinical study to augment the dataset aggregated from external sources. We optimized five deep learning architectures, implemented development strategies by manipulating data distribution to quantitatively compare study designs, and introduced several detection scenarios to evaluate the robustness and diagnostic performance of the models. At the current level of data availability, the performance of the detection model depends on the hyperparameter tuning and has less dependency on the quantity of data. InceptionV3 attained the highest performance in distinguishing pneumonia from normal CXR in two-class detection scenario with sensitivity (Sn), specificity (Sp), and positive predictive value (PPV) of 96%. The models attained higher general performance of 91-96% Sn, 94-98% Sp, and 90-96% PPV in three-class compared to four-class detection scenario. InceptionV3 has the highest general performance with accuracy, F1-score, and g-mean of 96% in the three-class detection scenario. For COVID-19 pneumonia detection, InceptionV3 attained the highest performance with 86% Sn, 99% Sp, and 91% PPV with an AUC of 0.99 in distinguishing pneumonia from normal CXR. Its capability of differentiating COVID-19 pneumonia from normal and non-COVID-19 pneumonia attained 0.98 AUC and a micro-average of 0.99 for other classes.
format Online
Article
Text
id pubmed-8516252
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-85162522021-10-15 Artificial intelligence on COVID-19 pneumonia detection using chest xray images Baltazar, Lei Rigi Manzanillo, Mojhune Gabriel Gaudillo, Joverlyn Viray, Ethel Dominique Domingo, Mario Tiangco, Beatrice Albia, Jason PLoS One Research Article Recent studies show the potential of artificial intelligence (AI) as a screening tool to detect COVID-19 pneumonia based on chest x-ray (CXR) images. However, issues on the datasets and study designs from medical and technical perspectives, as well as questions on the vulnerability and robustness of AI algorithms have emerged. In this study, we address these issues with a more realistic development of AI-driven COVID-19 pneumonia detection models by generating our own data through a retrospective clinical study to augment the dataset aggregated from external sources. We optimized five deep learning architectures, implemented development strategies by manipulating data distribution to quantitatively compare study designs, and introduced several detection scenarios to evaluate the robustness and diagnostic performance of the models. At the current level of data availability, the performance of the detection model depends on the hyperparameter tuning and has less dependency on the quantity of data. InceptionV3 attained the highest performance in distinguishing pneumonia from normal CXR in two-class detection scenario with sensitivity (Sn), specificity (Sp), and positive predictive value (PPV) of 96%. The models attained higher general performance of 91-96% Sn, 94-98% Sp, and 90-96% PPV in three-class compared to four-class detection scenario. InceptionV3 has the highest general performance with accuracy, F1-score, and g-mean of 96% in the three-class detection scenario. For COVID-19 pneumonia detection, InceptionV3 attained the highest performance with 86% Sn, 99% Sp, and 91% PPV with an AUC of 0.99 in distinguishing pneumonia from normal CXR. Its capability of differentiating COVID-19 pneumonia from normal and non-COVID-19 pneumonia attained 0.98 AUC and a micro-average of 0.99 for other classes. Public Library of Science 2021-10-14 /pmc/articles/PMC8516252/ /pubmed/34648509 http://dx.doi.org/10.1371/journal.pone.0257884 Text en © 2021 Baltazar et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Baltazar, Lei Rigi
Manzanillo, Mojhune Gabriel
Gaudillo, Joverlyn
Viray, Ethel Dominique
Domingo, Mario
Tiangco, Beatrice
Albia, Jason
Artificial intelligence on COVID-19 pneumonia detection using chest xray images
title Artificial intelligence on COVID-19 pneumonia detection using chest xray images
title_full Artificial intelligence on COVID-19 pneumonia detection using chest xray images
title_fullStr Artificial intelligence on COVID-19 pneumonia detection using chest xray images
title_full_unstemmed Artificial intelligence on COVID-19 pneumonia detection using chest xray images
title_short Artificial intelligence on COVID-19 pneumonia detection using chest xray images
title_sort artificial intelligence on covid-19 pneumonia detection using chest xray images
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8516252/
https://www.ncbi.nlm.nih.gov/pubmed/34648509
http://dx.doi.org/10.1371/journal.pone.0257884
work_keys_str_mv AT baltazarleirigi artificialintelligenceoncovid19pneumoniadetectionusingchestxrayimages
AT manzanillomojhunegabriel artificialintelligenceoncovid19pneumoniadetectionusingchestxrayimages
AT gaudillojoverlyn artificialintelligenceoncovid19pneumoniadetectionusingchestxrayimages
AT virayetheldominique artificialintelligenceoncovid19pneumoniadetectionusingchestxrayimages
AT domingomario artificialintelligenceoncovid19pneumoniadetectionusingchestxrayimages
AT tiangcobeatrice artificialintelligenceoncovid19pneumoniadetectionusingchestxrayimages
AT albiajason artificialintelligenceoncovid19pneumoniadetectionusingchestxrayimages