Cargando…
Carbon nanotube field-effect transistor (CNT-FET)-based biosensor for rapid detection of SARS-CoV-2 (COVID-19) surface spike protein S1
The large-scale diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is important for traceability and treatment during pandemic outbreaks. We developed a fast (2–3 min), easy-to-use, low-cost, and quantitative electrochemical biosensor based on carbon nanotube field-effect tran...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Authors. Published by Elsevier B.V.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8518145/ https://www.ncbi.nlm.nih.gov/pubmed/34715586 http://dx.doi.org/10.1016/j.bioelechem.2021.107982 |
_version_ | 1784584162498314240 |
---|---|
author | Zamzami, Mazin A. Rabbani, Gulam Ahmad, Abrar Basalah, Ahmad A. Al-Sabban, Wesam H. Nate Ahn, Saeyoung Choudhry, Hani |
author_facet | Zamzami, Mazin A. Rabbani, Gulam Ahmad, Abrar Basalah, Ahmad A. Al-Sabban, Wesam H. Nate Ahn, Saeyoung Choudhry, Hani |
author_sort | Zamzami, Mazin A. |
collection | PubMed |
description | The large-scale diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is important for traceability and treatment during pandemic outbreaks. We developed a fast (2–3 min), easy-to-use, low-cost, and quantitative electrochemical biosensor based on carbon nanotube field-effect transistor (CNT-FET) that allows digital detection of the SARS-CoV-2 S1 in fortifited saliva samples for quick and accurate detection of SARS-CoV-2 S1 antigens. The biosensor was developed on a Si/SiO(2) surface by CNT printing with the immobilization of a anti-SARS-CoV-2 S1. SARS-CoV-2 S1 antibody was immobilized on the CNT surface between the S-D channel area using a linker 1-pyrenebutanoic acid succinimidyl ester (PBASE) through non-covalent interaction. A commercial SARS-CoV-2 S1 antigen was used to characterize the electrical output of the CNT-FET biosensor. The SARS-CoV-2 S1 antigen in the 10 mM AA buffer pH 6.0 was effectively detected by the CNT-FET biosensor at concentrations from 0.1 fg/mL to 5.0 pg/mL. The limit of detection (LOD) of the developed CNT-FET biosensor was 4.12 fg/mL. The selectivity test was performed by using target SARS-CoV-2 S1 and non-target SARS-CoV-1 S1 and MERS-CoV S1 antigens in the 10 mM AA buffer pH 6.0. The biosensor showed high selectivity (no response to SARS-CoV-1 S1 or MERS-CoV S1 antigen) with SARS-CoV-2 S1 antigen detection in the 10 mM AA buffer pH 6.0. The biosensor is highly sensitive, saves time, and could be a helpful platform for rapid detection of SARS-CoV-2 S1 antigen from the patients saliva. |
format | Online Article Text |
id | pubmed-8518145 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | The Authors. Published by Elsevier B.V. |
record_format | MEDLINE/PubMed |
spelling | pubmed-85181452021-10-15 Carbon nanotube field-effect transistor (CNT-FET)-based biosensor for rapid detection of SARS-CoV-2 (COVID-19) surface spike protein S1 Zamzami, Mazin A. Rabbani, Gulam Ahmad, Abrar Basalah, Ahmad A. Al-Sabban, Wesam H. Nate Ahn, Saeyoung Choudhry, Hani Bioelectrochemistry Article The large-scale diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is important for traceability and treatment during pandemic outbreaks. We developed a fast (2–3 min), easy-to-use, low-cost, and quantitative electrochemical biosensor based on carbon nanotube field-effect transistor (CNT-FET) that allows digital detection of the SARS-CoV-2 S1 in fortifited saliva samples for quick and accurate detection of SARS-CoV-2 S1 antigens. The biosensor was developed on a Si/SiO(2) surface by CNT printing with the immobilization of a anti-SARS-CoV-2 S1. SARS-CoV-2 S1 antibody was immobilized on the CNT surface between the S-D channel area using a linker 1-pyrenebutanoic acid succinimidyl ester (PBASE) through non-covalent interaction. A commercial SARS-CoV-2 S1 antigen was used to characterize the electrical output of the CNT-FET biosensor. The SARS-CoV-2 S1 antigen in the 10 mM AA buffer pH 6.0 was effectively detected by the CNT-FET biosensor at concentrations from 0.1 fg/mL to 5.0 pg/mL. The limit of detection (LOD) of the developed CNT-FET biosensor was 4.12 fg/mL. The selectivity test was performed by using target SARS-CoV-2 S1 and non-target SARS-CoV-1 S1 and MERS-CoV S1 antigens in the 10 mM AA buffer pH 6.0. The biosensor showed high selectivity (no response to SARS-CoV-1 S1 or MERS-CoV S1 antigen) with SARS-CoV-2 S1 antigen detection in the 10 mM AA buffer pH 6.0. The biosensor is highly sensitive, saves time, and could be a helpful platform for rapid detection of SARS-CoV-2 S1 antigen from the patients saliva. The Authors. Published by Elsevier B.V. 2022-02 2021-10-15 /pmc/articles/PMC8518145/ /pubmed/34715586 http://dx.doi.org/10.1016/j.bioelechem.2021.107982 Text en © 2021 The Authors Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Article Zamzami, Mazin A. Rabbani, Gulam Ahmad, Abrar Basalah, Ahmad A. Al-Sabban, Wesam H. Nate Ahn, Saeyoung Choudhry, Hani Carbon nanotube field-effect transistor (CNT-FET)-based biosensor for rapid detection of SARS-CoV-2 (COVID-19) surface spike protein S1 |
title | Carbon nanotube field-effect transistor (CNT-FET)-based biosensor for rapid detection of SARS-CoV-2 (COVID-19) surface spike protein S1 |
title_full | Carbon nanotube field-effect transistor (CNT-FET)-based biosensor for rapid detection of SARS-CoV-2 (COVID-19) surface spike protein S1 |
title_fullStr | Carbon nanotube field-effect transistor (CNT-FET)-based biosensor for rapid detection of SARS-CoV-2 (COVID-19) surface spike protein S1 |
title_full_unstemmed | Carbon nanotube field-effect transistor (CNT-FET)-based biosensor for rapid detection of SARS-CoV-2 (COVID-19) surface spike protein S1 |
title_short | Carbon nanotube field-effect transistor (CNT-FET)-based biosensor for rapid detection of SARS-CoV-2 (COVID-19) surface spike protein S1 |
title_sort | carbon nanotube field-effect transistor (cnt-fet)-based biosensor for rapid detection of sars-cov-2 (covid-19) surface spike protein s1 |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8518145/ https://www.ncbi.nlm.nih.gov/pubmed/34715586 http://dx.doi.org/10.1016/j.bioelechem.2021.107982 |
work_keys_str_mv | AT zamzamimazina carbonnanotubefieldeffecttransistorcntfetbasedbiosensorforrapiddetectionofsarscov2covid19surfacespikeproteins1 AT rabbanigulam carbonnanotubefieldeffecttransistorcntfetbasedbiosensorforrapiddetectionofsarscov2covid19surfacespikeproteins1 AT ahmadabrar carbonnanotubefieldeffecttransistorcntfetbasedbiosensorforrapiddetectionofsarscov2covid19surfacespikeproteins1 AT basalahahmada carbonnanotubefieldeffecttransistorcntfetbasedbiosensorforrapiddetectionofsarscov2covid19surfacespikeproteins1 AT alsabbanwesamh carbonnanotubefieldeffecttransistorcntfetbasedbiosensorforrapiddetectionofsarscov2covid19surfacespikeproteins1 AT nateahnsaeyoung carbonnanotubefieldeffecttransistorcntfetbasedbiosensorforrapiddetectionofsarscov2covid19surfacespikeproteins1 AT choudhryhani carbonnanotubefieldeffecttransistorcntfetbasedbiosensorforrapiddetectionofsarscov2covid19surfacespikeproteins1 |