Design of clinical trials to assess diabetes treatment: Minimum duration of continuous glucose monitoring data to estimate time‐in‐ranges with the desired precision

AIM: To compute the uncertainty of time‐in‐ranges, such as time in range (TIR), time in tight range (TITR), time below range (TBR) and time above range (TAR), to evaluate glucose control and to determine the minimum duration of a trial to achieve the desired precision. MATERIALS AND METHODS: Four fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Camerlingo, Nunzio, Vettoretti, Martina, Sparacino, Giovanni, Facchinetti, Andrea, Mader, Julia K., Choudhary, Pratik, Del Favero, Simone
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Blackwell Publishing Ltd 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8518626/
https://www.ncbi.nlm.nih.gov/pubmed/34212483
http://dx.doi.org/10.1111/dom.14483