Cargando…

Accuracy of Pretreatment Ultrasonography Assessment of Intra-Abdominal Spread in Epithelial Ovarian Cancer: A Prospective Study

The aim of this study was to test the accuracy of ultrasonography performed by gynecological oncologists for the preoperative assessment of epithelial ovarian cancer (EOC) spread in the pelvis and abdominal cavity. A prospective, observational cohort study was performed at a single tertiary cancer c...

Descripción completa

Detalles Bibliográficos
Autores principales: Tomasińska, Agnieszka, Stukan, Maciej, Badocha, Michał, Myszewska, Aleksandra
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8519008/
https://www.ncbi.nlm.nih.gov/pubmed/34573942
http://dx.doi.org/10.3390/diagnostics11091600
_version_ 1784584360211513344
author Tomasińska, Agnieszka
Stukan, Maciej
Badocha, Michał
Myszewska, Aleksandra
author_facet Tomasińska, Agnieszka
Stukan, Maciej
Badocha, Michał
Myszewska, Aleksandra
author_sort Tomasińska, Agnieszka
collection PubMed
description The aim of this study was to test the accuracy of ultrasonography performed by gynecological oncologists for the preoperative assessment of epithelial ovarian cancer (EOC) spread in the pelvis and abdominal cavity. A prospective, observational cohort study was performed at a single tertiary cancer care unit. Patients with suspected EOC were recruited and underwent comprehensive transvaginal and abdominal ultrasonography performed by a gynecological oncologist. Sixteen intra-abdominal localizations and parameters were assessed using ultrasonography and compared with surgical-pathological status (reference standard). Sensitivity, specificity, positive and negative predictive values, and overall accuracy were calculated. Differences were analyzed using Fisher’s exact and chi-square tests. Ultimately, we included 132 patients (median age 62 years), of whom 67% were in stage IIIC–IVB and 72% had serous cancer. Overall prediction accuracies for the involvement of the omentum, small bowel mesentery root, and frozen pelvis, and detecting ascites were >90%. Detecting the involvement of the pelvis peritoneum, liver and spleen hilum, and rectosigmoid colon, and predictions of disease stage and residual disease had overall accuracies of 80–90%. The lowest accuracy was for involvement of the abdominal peritoneum (69%) and diaphragm peritoneum (right 71%; left 75%) and surgical complexity prediction (77%). Stratification of results by presence or absence of ascites revealed significantly higher specificity of ultrasonography (clinically meaningful) for assessments of the abdominal/pelvic peritoneum, spleen hilum, and rectum wall, if there were ascites. A gynecological oncologist, experienced in surgery and sonology, performing comprehensive ultrasonography on patients with EOC can accurately detect intraperitoneal lesions and recognize critical disease manifestations and predict stage, surgical complexity, and residual disease, which allow accurate qualification of patients for primary debulking surgery or neoadjuvant chemotherapy.
format Online
Article
Text
id pubmed-8519008
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-85190082021-10-16 Accuracy of Pretreatment Ultrasonography Assessment of Intra-Abdominal Spread in Epithelial Ovarian Cancer: A Prospective Study Tomasińska, Agnieszka Stukan, Maciej Badocha, Michał Myszewska, Aleksandra Diagnostics (Basel) Article The aim of this study was to test the accuracy of ultrasonography performed by gynecological oncologists for the preoperative assessment of epithelial ovarian cancer (EOC) spread in the pelvis and abdominal cavity. A prospective, observational cohort study was performed at a single tertiary cancer care unit. Patients with suspected EOC were recruited and underwent comprehensive transvaginal and abdominal ultrasonography performed by a gynecological oncologist. Sixteen intra-abdominal localizations and parameters were assessed using ultrasonography and compared with surgical-pathological status (reference standard). Sensitivity, specificity, positive and negative predictive values, and overall accuracy were calculated. Differences were analyzed using Fisher’s exact and chi-square tests. Ultimately, we included 132 patients (median age 62 years), of whom 67% were in stage IIIC–IVB and 72% had serous cancer. Overall prediction accuracies for the involvement of the omentum, small bowel mesentery root, and frozen pelvis, and detecting ascites were >90%. Detecting the involvement of the pelvis peritoneum, liver and spleen hilum, and rectosigmoid colon, and predictions of disease stage and residual disease had overall accuracies of 80–90%. The lowest accuracy was for involvement of the abdominal peritoneum (69%) and diaphragm peritoneum (right 71%; left 75%) and surgical complexity prediction (77%). Stratification of results by presence or absence of ascites revealed significantly higher specificity of ultrasonography (clinically meaningful) for assessments of the abdominal/pelvic peritoneum, spleen hilum, and rectum wall, if there were ascites. A gynecological oncologist, experienced in surgery and sonology, performing comprehensive ultrasonography on patients with EOC can accurately detect intraperitoneal lesions and recognize critical disease manifestations and predict stage, surgical complexity, and residual disease, which allow accurate qualification of patients for primary debulking surgery or neoadjuvant chemotherapy. MDPI 2021-09-02 /pmc/articles/PMC8519008/ /pubmed/34573942 http://dx.doi.org/10.3390/diagnostics11091600 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Tomasińska, Agnieszka
Stukan, Maciej
Badocha, Michał
Myszewska, Aleksandra
Accuracy of Pretreatment Ultrasonography Assessment of Intra-Abdominal Spread in Epithelial Ovarian Cancer: A Prospective Study
title Accuracy of Pretreatment Ultrasonography Assessment of Intra-Abdominal Spread in Epithelial Ovarian Cancer: A Prospective Study
title_full Accuracy of Pretreatment Ultrasonography Assessment of Intra-Abdominal Spread in Epithelial Ovarian Cancer: A Prospective Study
title_fullStr Accuracy of Pretreatment Ultrasonography Assessment of Intra-Abdominal Spread in Epithelial Ovarian Cancer: A Prospective Study
title_full_unstemmed Accuracy of Pretreatment Ultrasonography Assessment of Intra-Abdominal Spread in Epithelial Ovarian Cancer: A Prospective Study
title_short Accuracy of Pretreatment Ultrasonography Assessment of Intra-Abdominal Spread in Epithelial Ovarian Cancer: A Prospective Study
title_sort accuracy of pretreatment ultrasonography assessment of intra-abdominal spread in epithelial ovarian cancer: a prospective study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8519008/
https://www.ncbi.nlm.nih.gov/pubmed/34573942
http://dx.doi.org/10.3390/diagnostics11091600
work_keys_str_mv AT tomasinskaagnieszka accuracyofpretreatmentultrasonographyassessmentofintraabdominalspreadinepithelialovariancanceraprospectivestudy
AT stukanmaciej accuracyofpretreatmentultrasonographyassessmentofintraabdominalspreadinepithelialovariancanceraprospectivestudy
AT badochamichał accuracyofpretreatmentultrasonographyassessmentofintraabdominalspreadinepithelialovariancanceraprospectivestudy
AT myszewskaaleksandra accuracyofpretreatmentultrasonographyassessmentofintraabdominalspreadinepithelialovariancanceraprospectivestudy