Cargando…

Results and complications of minimally invasive medial plate osteosynthesis for distal metaphyseal tibial fractures: A prospective case series from Vietnam

INTRODUCTION AND IMPORTANCE: The treatment of a fractures in tibial distal metaphyseal remained controversial. The purpose of this study was to assess the results and complications of minimally invasive medial plate osteosynthesis for distal metaphyseal tibial fractures. MATERIAL AND METHOD: From Ap...

Descripción completa

Detalles Bibliográficos
Autores principales: Van Nguyen, Luong, Nguyen, Gioi Nang, Nguyen, Binh Lam, Bui, Ha Manh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8519768/
https://www.ncbi.nlm.nih.gov/pubmed/34691427
http://dx.doi.org/10.1016/j.amsu.2021.102886
_version_ 1784584520533540864
author Van Nguyen, Luong
Nguyen, Gioi Nang
Nguyen, Binh Lam
Bui, Ha Manh
author_facet Van Nguyen, Luong
Nguyen, Gioi Nang
Nguyen, Binh Lam
Bui, Ha Manh
author_sort Van Nguyen, Luong
collection PubMed
description INTRODUCTION AND IMPORTANCE: The treatment of a fractures in tibial distal metaphyseal remained controversial. The purpose of this study was to assess the results and complications of minimally invasive medial plate osteosynthesis for distal metaphyseal tibial fractures. MATERIAL AND METHOD: From April 2014 to December 2019, 70 patients were enrolled in the study who were underwent MIPPO for metaphyseal tibial fractures using a medial distal tibial locking plate in our hospital. Wound healing, alignment, full weight bearing time, function, and complications were recorded. RESULTS: All wounds primarily healed, just one fibular plating wound was deeply infected. All tibial fractures were solid union without secondary displacement. The average time back to walk without a crutch was 12,5 weeks. The mean AOFAS score was 89 at a mean of 15 months follow-up. There were seven cases of late infection, 14 patients of skin impingement by implants and nine cases of broken screws, who were older than 65 years old. No case was varus, valgus or rotation >5°. CONCLUSION: Minimally invasive medial plate osteosynthesis for the distal metaphyseal tibial fracture is safe and effective. This technique decreases the incidence of complications and can help patients to resume their function early. The implant impingement, late wound infections and screw breakage were the quite common complications in old patients but these complications could be simply resolved and did not affect the overall rehabilitation and functions of the patient.
format Online
Article
Text
id pubmed-8519768
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-85197682021-10-21 Results and complications of minimally invasive medial plate osteosynthesis for distal metaphyseal tibial fractures: A prospective case series from Vietnam Van Nguyen, Luong Nguyen, Gioi Nang Nguyen, Binh Lam Bui, Ha Manh Ann Med Surg (Lond) Case Series INTRODUCTION AND IMPORTANCE: The treatment of a fractures in tibial distal metaphyseal remained controversial. The purpose of this study was to assess the results and complications of minimally invasive medial plate osteosynthesis for distal metaphyseal tibial fractures. MATERIAL AND METHOD: From April 2014 to December 2019, 70 patients were enrolled in the study who were underwent MIPPO for metaphyseal tibial fractures using a medial distal tibial locking plate in our hospital. Wound healing, alignment, full weight bearing time, function, and complications were recorded. RESULTS: All wounds primarily healed, just one fibular plating wound was deeply infected. All tibial fractures were solid union without secondary displacement. The average time back to walk without a crutch was 12,5 weeks. The mean AOFAS score was 89 at a mean of 15 months follow-up. There were seven cases of late infection, 14 patients of skin impingement by implants and nine cases of broken screws, who were older than 65 years old. No case was varus, valgus or rotation >5°. CONCLUSION: Minimally invasive medial plate osteosynthesis for the distal metaphyseal tibial fracture is safe and effective. This technique decreases the incidence of complications and can help patients to resume their function early. The implant impingement, late wound infections and screw breakage were the quite common complications in old patients but these complications could be simply resolved and did not affect the overall rehabilitation and functions of the patient. Elsevier 2021-09-22 /pmc/articles/PMC8519768/ /pubmed/34691427 http://dx.doi.org/10.1016/j.amsu.2021.102886 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Series
Van Nguyen, Luong
Nguyen, Gioi Nang
Nguyen, Binh Lam
Bui, Ha Manh
Results and complications of minimally invasive medial plate osteosynthesis for distal metaphyseal tibial fractures: A prospective case series from Vietnam
title Results and complications of minimally invasive medial plate osteosynthesis for distal metaphyseal tibial fractures: A prospective case series from Vietnam
title_full Results and complications of minimally invasive medial plate osteosynthesis for distal metaphyseal tibial fractures: A prospective case series from Vietnam
title_fullStr Results and complications of minimally invasive medial plate osteosynthesis for distal metaphyseal tibial fractures: A prospective case series from Vietnam
title_full_unstemmed Results and complications of minimally invasive medial plate osteosynthesis for distal metaphyseal tibial fractures: A prospective case series from Vietnam
title_short Results and complications of minimally invasive medial plate osteosynthesis for distal metaphyseal tibial fractures: A prospective case series from Vietnam
title_sort results and complications of minimally invasive medial plate osteosynthesis for distal metaphyseal tibial fractures: a prospective case series from vietnam
topic Case Series
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8519768/
https://www.ncbi.nlm.nih.gov/pubmed/34691427
http://dx.doi.org/10.1016/j.amsu.2021.102886
work_keys_str_mv AT vannguyenluong resultsandcomplicationsofminimallyinvasivemedialplateosteosynthesisfordistalmetaphysealtibialfracturesaprospectivecaseseriesfromvietnam
AT nguyengioinang resultsandcomplicationsofminimallyinvasivemedialplateosteosynthesisfordistalmetaphysealtibialfracturesaprospectivecaseseriesfromvietnam
AT nguyenbinhlam resultsandcomplicationsofminimallyinvasivemedialplateosteosynthesisfordistalmetaphysealtibialfracturesaprospectivecaseseriesfromvietnam
AT buihamanh resultsandcomplicationsofminimallyinvasivemedialplateosteosynthesisfordistalmetaphysealtibialfracturesaprospectivecaseseriesfromvietnam