Cargando…

Diagnostic accuracy of synovial fluid D-lactate for periprosthetic joint infection: a systematic review and meta-analysis

BACKGROUND: Periprosthetic joint infection is a grievous complication after arthroplasty that greatly affects the quality of life of patients. Rapid establishment of infection diagnosis is essential, but great challenges still exist. METHODS: We conducted research in the PubMed, Embase, and Cochrane...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Zhizhuo, Li, Chengxin, Wang, Guangxue, Shi, Lijun, Li, Tengqi, Fan, Xiaoyu, Xu, Xin, Wang, Peixu, Gao, Fuqiang, Sun, Wei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8520230/
https://www.ncbi.nlm.nih.gov/pubmed/34656157
http://dx.doi.org/10.1186/s13018-021-02778-8
_version_ 1784584625298866176
author Li, Zhizhuo
Li, Chengxin
Wang, Guangxue
Shi, Lijun
Li, Tengqi
Fan, Xiaoyu
Xu, Xin
Wang, Peixu
Gao, Fuqiang
Sun, Wei
author_facet Li, Zhizhuo
Li, Chengxin
Wang, Guangxue
Shi, Lijun
Li, Tengqi
Fan, Xiaoyu
Xu, Xin
Wang, Peixu
Gao, Fuqiang
Sun, Wei
author_sort Li, Zhizhuo
collection PubMed
description BACKGROUND: Periprosthetic joint infection is a grievous complication after arthroplasty that greatly affects the quality of life of patients. Rapid establishment of infection diagnosis is essential, but great challenges still exist. METHODS: We conducted research in the PubMed, Embase, and Cochrane databases to evaluate the diagnostic accuracy of D-lactate for PJI. Data extraction and quality assessment were completed independently by two reviewers. The pooled sensitivity, specificity, likelihood ratios, diagnostic odds ratio (DOR), summarized receiver operating characteristic curve (sROC), and area under the sROC curve (AUC) were constructed using the bivariate meta-analysis framework. RESULTS: Five eligible studies were included in the quantitative analysis. The pooled sensitivity and specificity of D-lactate for the diagnosis of PJI were 0.82 (95% CI 0.70–0.89) and 0.76 (95% CI 0.69–0.82), respectively. The value of the pooled diagnostic odds ratio (DOR) of D-lactate for PJI was 14.18 (95% CI 6.17–32.58), and the area under the curve (AUC) was 0.84 (95% CI 0.80–0.87). CONCLUSIONS: According to the results of our meta-analysis, D-lactate is a valuable synovial fluid marker for recognizing PJI, with high sensitivity and specificity.
format Online
Article
Text
id pubmed-8520230
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-85202302021-10-20 Diagnostic accuracy of synovial fluid D-lactate for periprosthetic joint infection: a systematic review and meta-analysis Li, Zhizhuo Li, Chengxin Wang, Guangxue Shi, Lijun Li, Tengqi Fan, Xiaoyu Xu, Xin Wang, Peixu Gao, Fuqiang Sun, Wei J Orthop Surg Res Systematic Review BACKGROUND: Periprosthetic joint infection is a grievous complication after arthroplasty that greatly affects the quality of life of patients. Rapid establishment of infection diagnosis is essential, but great challenges still exist. METHODS: We conducted research in the PubMed, Embase, and Cochrane databases to evaluate the diagnostic accuracy of D-lactate for PJI. Data extraction and quality assessment were completed independently by two reviewers. The pooled sensitivity, specificity, likelihood ratios, diagnostic odds ratio (DOR), summarized receiver operating characteristic curve (sROC), and area under the sROC curve (AUC) were constructed using the bivariate meta-analysis framework. RESULTS: Five eligible studies were included in the quantitative analysis. The pooled sensitivity and specificity of D-lactate for the diagnosis of PJI were 0.82 (95% CI 0.70–0.89) and 0.76 (95% CI 0.69–0.82), respectively. The value of the pooled diagnostic odds ratio (DOR) of D-lactate for PJI was 14.18 (95% CI 6.17–32.58), and the area under the curve (AUC) was 0.84 (95% CI 0.80–0.87). CONCLUSIONS: According to the results of our meta-analysis, D-lactate is a valuable synovial fluid marker for recognizing PJI, with high sensitivity and specificity. BioMed Central 2021-10-16 /pmc/articles/PMC8520230/ /pubmed/34656157 http://dx.doi.org/10.1186/s13018-021-02778-8 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Systematic Review
Li, Zhizhuo
Li, Chengxin
Wang, Guangxue
Shi, Lijun
Li, Tengqi
Fan, Xiaoyu
Xu, Xin
Wang, Peixu
Gao, Fuqiang
Sun, Wei
Diagnostic accuracy of synovial fluid D-lactate for periprosthetic joint infection: a systematic review and meta-analysis
title Diagnostic accuracy of synovial fluid D-lactate for periprosthetic joint infection: a systematic review and meta-analysis
title_full Diagnostic accuracy of synovial fluid D-lactate for periprosthetic joint infection: a systematic review and meta-analysis
title_fullStr Diagnostic accuracy of synovial fluid D-lactate for periprosthetic joint infection: a systematic review and meta-analysis
title_full_unstemmed Diagnostic accuracy of synovial fluid D-lactate for periprosthetic joint infection: a systematic review and meta-analysis
title_short Diagnostic accuracy of synovial fluid D-lactate for periprosthetic joint infection: a systematic review and meta-analysis
title_sort diagnostic accuracy of synovial fluid d-lactate for periprosthetic joint infection: a systematic review and meta-analysis
topic Systematic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8520230/
https://www.ncbi.nlm.nih.gov/pubmed/34656157
http://dx.doi.org/10.1186/s13018-021-02778-8
work_keys_str_mv AT lizhizhuo diagnosticaccuracyofsynovialfluiddlactateforperiprostheticjointinfectionasystematicreviewandmetaanalysis
AT lichengxin diagnosticaccuracyofsynovialfluiddlactateforperiprostheticjointinfectionasystematicreviewandmetaanalysis
AT wangguangxue diagnosticaccuracyofsynovialfluiddlactateforperiprostheticjointinfectionasystematicreviewandmetaanalysis
AT shilijun diagnosticaccuracyofsynovialfluiddlactateforperiprostheticjointinfectionasystematicreviewandmetaanalysis
AT litengqi diagnosticaccuracyofsynovialfluiddlactateforperiprostheticjointinfectionasystematicreviewandmetaanalysis
AT fanxiaoyu diagnosticaccuracyofsynovialfluiddlactateforperiprostheticjointinfectionasystematicreviewandmetaanalysis
AT xuxin diagnosticaccuracyofsynovialfluiddlactateforperiprostheticjointinfectionasystematicreviewandmetaanalysis
AT wangpeixu diagnosticaccuracyofsynovialfluiddlactateforperiprostheticjointinfectionasystematicreviewandmetaanalysis
AT gaofuqiang diagnosticaccuracyofsynovialfluiddlactateforperiprostheticjointinfectionasystematicreviewandmetaanalysis
AT sunwei diagnosticaccuracyofsynovialfluiddlactateforperiprostheticjointinfectionasystematicreviewandmetaanalysis