Cargando…
Shape-sensing robotic-assisted bronchoscopy for pulmonary nodules: initial multicenter experience using the Ion™ Endoluminal System
BACKGROUND: Traditional bronchoscopy provides limited approach to peripheral nodules. Shape-sensing robotic-assisted bronchoscopy (SSRAB, Ion™ Endoluminal System) is a new tool for minimally invasive peripheral nodule biopsy. We sought to answer the research question: Does SSRAB facilitate sampling...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8520632/ https://www.ncbi.nlm.nih.gov/pubmed/34656103 http://dx.doi.org/10.1186/s12890-021-01693-2 |
_version_ | 1784584709216403456 |
---|---|
author | Simoff, Michael J. Pritchett, Michael A. Reisenauer, Janani S. Ost, David E. Majid, Adnan Keyes, Colleen Casal, Roberto F. Parikh, Mihir S. Diaz-Mendoza, Javier Fernandez-Bussy, Sebastian Folch, Erik E. |
author_facet | Simoff, Michael J. Pritchett, Michael A. Reisenauer, Janani S. Ost, David E. Majid, Adnan Keyes, Colleen Casal, Roberto F. Parikh, Mihir S. Diaz-Mendoza, Javier Fernandez-Bussy, Sebastian Folch, Erik E. |
author_sort | Simoff, Michael J. |
collection | PubMed |
description | BACKGROUND: Traditional bronchoscopy provides limited approach to peripheral nodules. Shape-sensing robotic-assisted bronchoscopy (SSRAB, Ion™ Endoluminal System) is a new tool for minimally invasive peripheral nodule biopsy. We sought to answer the research question: Does SSRAB facilitate sampling of pulmonary nodules during bronchoscopists’ initial experience? METHODS: The lead-in stage of a multicenter, single-arm, prospective evaluation of the Ion Endoluminal System (PRECIsE) is described. Enrolled subjects ≥ 18 years old had recent computed tomography evidence of one or more solid or semi-solid pulmonary nodules ≥ 1.0 to ≤ 3.5 cm in greatest dimension and in any part of the lung. Subjects were followed at 10- and 30-days post-procedure. This stage provided investigators and staff their first human experience with the SSRAB system; safety and procedure outcomes were analyzed descriptively. Neither diagnostic yield nor sensitivity for malignancy were assessed in this stage. Categorical variables are summarized by percentage; continuous variables are summarized by median/interquartile range (IQR). RESULTS: Sixty subjects were enrolled across 6 hospitals; 67 nodules were targeted for biopsy. Median axial, coronal and sagittal diameters were < 18 mm with a largest cardinal diameter of 20.0 mm. Most nodules were extraluminal and distance from the outer edge of the nodule to the pleura or nearest fissure was 4.0 mm (IQR: 0.0, 15.0). Median bronchial generation count to the target location was 7.0 (IQR: 6.0, 8.0). Procedure duration (catheter-in to catheter-out) was 66.5 min (IQR: 50.0, 85.5). Distance from the catheter tip to the closest edge of the virtual nodule was 7.0 mm (IQR: 2.0, 12.0). Biopsy completion was 97.0%. No pneumothorax or airway bleeding of any grade was reported. CONCLUSIONS: Bronchoscopists leveraged the Ion SSRAB’s functionality to drive the catheter safely in close proximity of the virtual target and to obtain biopsies. This initial, multicenter experience is encouraging, suggesting that SSRAB may play a role in the management of pulmonary nodules. Clinical Trial Registration identifier and date NCT03893539; 28/03/2019. |
format | Online Article Text |
id | pubmed-8520632 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-85206322021-10-20 Shape-sensing robotic-assisted bronchoscopy for pulmonary nodules: initial multicenter experience using the Ion™ Endoluminal System Simoff, Michael J. Pritchett, Michael A. Reisenauer, Janani S. Ost, David E. Majid, Adnan Keyes, Colleen Casal, Roberto F. Parikh, Mihir S. Diaz-Mendoza, Javier Fernandez-Bussy, Sebastian Folch, Erik E. BMC Pulm Med Research BACKGROUND: Traditional bronchoscopy provides limited approach to peripheral nodules. Shape-sensing robotic-assisted bronchoscopy (SSRAB, Ion™ Endoluminal System) is a new tool for minimally invasive peripheral nodule biopsy. We sought to answer the research question: Does SSRAB facilitate sampling of pulmonary nodules during bronchoscopists’ initial experience? METHODS: The lead-in stage of a multicenter, single-arm, prospective evaluation of the Ion Endoluminal System (PRECIsE) is described. Enrolled subjects ≥ 18 years old had recent computed tomography evidence of one or more solid or semi-solid pulmonary nodules ≥ 1.0 to ≤ 3.5 cm in greatest dimension and in any part of the lung. Subjects were followed at 10- and 30-days post-procedure. This stage provided investigators and staff their first human experience with the SSRAB system; safety and procedure outcomes were analyzed descriptively. Neither diagnostic yield nor sensitivity for malignancy were assessed in this stage. Categorical variables are summarized by percentage; continuous variables are summarized by median/interquartile range (IQR). RESULTS: Sixty subjects were enrolled across 6 hospitals; 67 nodules were targeted for biopsy. Median axial, coronal and sagittal diameters were < 18 mm with a largest cardinal diameter of 20.0 mm. Most nodules were extraluminal and distance from the outer edge of the nodule to the pleura or nearest fissure was 4.0 mm (IQR: 0.0, 15.0). Median bronchial generation count to the target location was 7.0 (IQR: 6.0, 8.0). Procedure duration (catheter-in to catheter-out) was 66.5 min (IQR: 50.0, 85.5). Distance from the catheter tip to the closest edge of the virtual nodule was 7.0 mm (IQR: 2.0, 12.0). Biopsy completion was 97.0%. No pneumothorax or airway bleeding of any grade was reported. CONCLUSIONS: Bronchoscopists leveraged the Ion SSRAB’s functionality to drive the catheter safely in close proximity of the virtual target and to obtain biopsies. This initial, multicenter experience is encouraging, suggesting that SSRAB may play a role in the management of pulmonary nodules. Clinical Trial Registration identifier and date NCT03893539; 28/03/2019. BioMed Central 2021-10-16 /pmc/articles/PMC8520632/ /pubmed/34656103 http://dx.doi.org/10.1186/s12890-021-01693-2 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Simoff, Michael J. Pritchett, Michael A. Reisenauer, Janani S. Ost, David E. Majid, Adnan Keyes, Colleen Casal, Roberto F. Parikh, Mihir S. Diaz-Mendoza, Javier Fernandez-Bussy, Sebastian Folch, Erik E. Shape-sensing robotic-assisted bronchoscopy for pulmonary nodules: initial multicenter experience using the Ion™ Endoluminal System |
title | Shape-sensing robotic-assisted bronchoscopy for pulmonary nodules: initial multicenter experience using the Ion™ Endoluminal System |
title_full | Shape-sensing robotic-assisted bronchoscopy for pulmonary nodules: initial multicenter experience using the Ion™ Endoluminal System |
title_fullStr | Shape-sensing robotic-assisted bronchoscopy for pulmonary nodules: initial multicenter experience using the Ion™ Endoluminal System |
title_full_unstemmed | Shape-sensing robotic-assisted bronchoscopy for pulmonary nodules: initial multicenter experience using the Ion™ Endoluminal System |
title_short | Shape-sensing robotic-assisted bronchoscopy for pulmonary nodules: initial multicenter experience using the Ion™ Endoluminal System |
title_sort | shape-sensing robotic-assisted bronchoscopy for pulmonary nodules: initial multicenter experience using the ion™ endoluminal system |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8520632/ https://www.ncbi.nlm.nih.gov/pubmed/34656103 http://dx.doi.org/10.1186/s12890-021-01693-2 |
work_keys_str_mv | AT simoffmichaelj shapesensingroboticassistedbronchoscopyforpulmonarynodulesinitialmulticenterexperienceusingtheionendoluminalsystem AT pritchettmichaela shapesensingroboticassistedbronchoscopyforpulmonarynodulesinitialmulticenterexperienceusingtheionendoluminalsystem AT reisenauerjananis shapesensingroboticassistedbronchoscopyforpulmonarynodulesinitialmulticenterexperienceusingtheionendoluminalsystem AT ostdavide shapesensingroboticassistedbronchoscopyforpulmonarynodulesinitialmulticenterexperienceusingtheionendoluminalsystem AT majidadnan shapesensingroboticassistedbronchoscopyforpulmonarynodulesinitialmulticenterexperienceusingtheionendoluminalsystem AT keyescolleen shapesensingroboticassistedbronchoscopyforpulmonarynodulesinitialmulticenterexperienceusingtheionendoluminalsystem AT casalrobertof shapesensingroboticassistedbronchoscopyforpulmonarynodulesinitialmulticenterexperienceusingtheionendoluminalsystem AT parikhmihirs shapesensingroboticassistedbronchoscopyforpulmonarynodulesinitialmulticenterexperienceusingtheionendoluminalsystem AT diazmendozajavier shapesensingroboticassistedbronchoscopyforpulmonarynodulesinitialmulticenterexperienceusingtheionendoluminalsystem AT fernandezbussysebastian shapesensingroboticassistedbronchoscopyforpulmonarynodulesinitialmulticenterexperienceusingtheionendoluminalsystem AT folcherike shapesensingroboticassistedbronchoscopyforpulmonarynodulesinitialmulticenterexperienceusingtheionendoluminalsystem |