Cargando…
Comparison of the canal transportation of ProTaper GOLD, WaveOne GOLD, and TruNatomy in simulated double-curved canals
BACKGROUND: In root canal preparations, it is important to maintain the original canal shape. However, it is difficult to accomplish this, especially due to the complex canal anatomy. This study aimed to compare the shaping ability of the ProTaper GOLD, WaveOne GOLD, and newly developed TruNatomy in...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8520641/ https://www.ncbi.nlm.nih.gov/pubmed/34656099 http://dx.doi.org/10.1186/s12903-021-01854-z |
_version_ | 1784584711186677760 |
---|---|
author | Kim, HyeWon Jeon, Su-Jin Seo, Min-Seock |
author_facet | Kim, HyeWon Jeon, Su-Jin Seo, Min-Seock |
author_sort | Kim, HyeWon |
collection | PubMed |
description | BACKGROUND: In root canal preparations, it is important to maintain the original canal shape. However, it is difficult to accomplish this, especially due to the complex canal anatomy. This study aimed to compare the shaping ability of the ProTaper GOLD, WaveOne GOLD, and newly developed TruNatomy in simulated S-shaped canals. METHODS: The root canals of 60 S-shaped resin blocks were dyed using ink and photographed. The blocks were then randomly divided into three groups: group ProTaper GOLD (n = 20), WaveOne GOLD (n = 20), and TruNatomy (n = 20). The simulated canals were instrumented according to the NiTi file system and photographed again after being dyed with red ink. The pre- and post-preparation images were superimposed, and the amount of resin removed from both the mesial and distal sides of the canal measured up to 9 mm from the apical terminus, with a 1 mm increment. The preparation time was also calculated. A paired t-test was used to determine the degree of deviation at different levels within the groups. To compare the degree of transportation at different levels between the groups, one-way ANOVA and Kruskal–Wallis tests were performed according to the normality. RESULTS: TruNatomy showed a significant deviation between the mesial and distal sides of the canal only in the coronal area at 6, 7, 8, and 9 mm levels of the canal (p < 0.05). When comparing the amount of transportation in the 3 groups at 9 different levels, TruNatomy showed significantly less canal transportation than the other groups at the 3-and 5-mm levels of the canal (p < 0.05), while ProTaper GOLD showed the largest amount of transportation in the apical curved area at the 2 and 3 mm levels (p < 0.05). TruNatomy removed less resin than other groups in all sections (p < 0.05), while ProTaper GOLD removed slightly more resin than WaveOne GOLD; however, there was no significant difference (p = 0.043). Shaping time was the least for TruNatomy, followed by the WaveOne GOLD and ProTaper GOLD (p < 0.05). CONCLUSIONS: TruNatomy maintained the original apical canal curvature in S-shaped curved canals better than ProTaper GOLD and WaveOne GOLD. |
format | Online Article Text |
id | pubmed-8520641 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-85206412021-10-20 Comparison of the canal transportation of ProTaper GOLD, WaveOne GOLD, and TruNatomy in simulated double-curved canals Kim, HyeWon Jeon, Su-Jin Seo, Min-Seock BMC Oral Health Research Article BACKGROUND: In root canal preparations, it is important to maintain the original canal shape. However, it is difficult to accomplish this, especially due to the complex canal anatomy. This study aimed to compare the shaping ability of the ProTaper GOLD, WaveOne GOLD, and newly developed TruNatomy in simulated S-shaped canals. METHODS: The root canals of 60 S-shaped resin blocks were dyed using ink and photographed. The blocks were then randomly divided into three groups: group ProTaper GOLD (n = 20), WaveOne GOLD (n = 20), and TruNatomy (n = 20). The simulated canals were instrumented according to the NiTi file system and photographed again after being dyed with red ink. The pre- and post-preparation images were superimposed, and the amount of resin removed from both the mesial and distal sides of the canal measured up to 9 mm from the apical terminus, with a 1 mm increment. The preparation time was also calculated. A paired t-test was used to determine the degree of deviation at different levels within the groups. To compare the degree of transportation at different levels between the groups, one-way ANOVA and Kruskal–Wallis tests were performed according to the normality. RESULTS: TruNatomy showed a significant deviation between the mesial and distal sides of the canal only in the coronal area at 6, 7, 8, and 9 mm levels of the canal (p < 0.05). When comparing the amount of transportation in the 3 groups at 9 different levels, TruNatomy showed significantly less canal transportation than the other groups at the 3-and 5-mm levels of the canal (p < 0.05), while ProTaper GOLD showed the largest amount of transportation in the apical curved area at the 2 and 3 mm levels (p < 0.05). TruNatomy removed less resin than other groups in all sections (p < 0.05), while ProTaper GOLD removed slightly more resin than WaveOne GOLD; however, there was no significant difference (p = 0.043). Shaping time was the least for TruNatomy, followed by the WaveOne GOLD and ProTaper GOLD (p < 0.05). CONCLUSIONS: TruNatomy maintained the original apical canal curvature in S-shaped curved canals better than ProTaper GOLD and WaveOne GOLD. BioMed Central 2021-10-16 /pmc/articles/PMC8520641/ /pubmed/34656099 http://dx.doi.org/10.1186/s12903-021-01854-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Kim, HyeWon Jeon, Su-Jin Seo, Min-Seock Comparison of the canal transportation of ProTaper GOLD, WaveOne GOLD, and TruNatomy in simulated double-curved canals |
title | Comparison of the canal transportation of ProTaper GOLD, WaveOne GOLD, and TruNatomy in simulated double-curved canals |
title_full | Comparison of the canal transportation of ProTaper GOLD, WaveOne GOLD, and TruNatomy in simulated double-curved canals |
title_fullStr | Comparison of the canal transportation of ProTaper GOLD, WaveOne GOLD, and TruNatomy in simulated double-curved canals |
title_full_unstemmed | Comparison of the canal transportation of ProTaper GOLD, WaveOne GOLD, and TruNatomy in simulated double-curved canals |
title_short | Comparison of the canal transportation of ProTaper GOLD, WaveOne GOLD, and TruNatomy in simulated double-curved canals |
title_sort | comparison of the canal transportation of protaper gold, waveone gold, and trunatomy in simulated double-curved canals |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8520641/ https://www.ncbi.nlm.nih.gov/pubmed/34656099 http://dx.doi.org/10.1186/s12903-021-01854-z |
work_keys_str_mv | AT kimhyewon comparisonofthecanaltransportationofprotapergoldwaveonegoldandtrunatomyinsimulateddoublecurvedcanals AT jeonsujin comparisonofthecanaltransportationofprotapergoldwaveonegoldandtrunatomyinsimulateddoublecurvedcanals AT seominseock comparisonofthecanaltransportationofprotapergoldwaveonegoldandtrunatomyinsimulateddoublecurvedcanals |