Cargando…
VentQsys: Low-cost open IoT system for [Formula: see text] monitoring in classrooms
In educational context, a source of nuisance for students is carbon dioxide ([Formula: see text] ) concentration due to closed rooms and lack of ventilation or circulatory air. Also, in the pandemic context, ventilation in indoor environments has been proven as a good tool to control the COVID-19 in...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8520892/ http://dx.doi.org/10.1007/s11276-021-02799-5 |
_version_ | 1784584777777545216 |
---|---|
author | Fayos-Jordan, Rafael Segura-Garcia, Jaume Soriano-Asensi, Antonio Felici-Castell, Santiago Felisi, Jose M. Alcaraz-Calero, Jose M. |
author_facet | Fayos-Jordan, Rafael Segura-Garcia, Jaume Soriano-Asensi, Antonio Felici-Castell, Santiago Felisi, Jose M. Alcaraz-Calero, Jose M. |
author_sort | Fayos-Jordan, Rafael |
collection | PubMed |
description | In educational context, a source of nuisance for students is carbon dioxide ([Formula: see text] ) concentration due to closed rooms and lack of ventilation or circulatory air. Also, in the pandemic context, ventilation in indoor environments has been proven as a good tool to control the COVID-19 infections. In this work, it is presented a low cost IoT-based open-hardware and open-software monitoring system to control ventilation, by measuring carbon dioxide ([Formula: see text] ), temperature and relative humidity. This system provides also support for automatic updating, auto-self calibration and adds some Cloud and Edge offloading of computational features for mapping functionalities. From the tests carried out, it is observed a good performance in terms of functionality, battery durability, compared to other measuring devices, more expensive than our proposal. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11276-021-02799-5. |
format | Online Article Text |
id | pubmed-8520892 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-85208922021-10-18 VentQsys: Low-cost open IoT system for [Formula: see text] monitoring in classrooms Fayos-Jordan, Rafael Segura-Garcia, Jaume Soriano-Asensi, Antonio Felici-Castell, Santiago Felisi, Jose M. Alcaraz-Calero, Jose M. Wireless Netw Original Paper In educational context, a source of nuisance for students is carbon dioxide ([Formula: see text] ) concentration due to closed rooms and lack of ventilation or circulatory air. Also, in the pandemic context, ventilation in indoor environments has been proven as a good tool to control the COVID-19 infections. In this work, it is presented a low cost IoT-based open-hardware and open-software monitoring system to control ventilation, by measuring carbon dioxide ([Formula: see text] ), temperature and relative humidity. This system provides also support for automatic updating, auto-self calibration and adds some Cloud and Edge offloading of computational features for mapping functionalities. From the tests carried out, it is observed a good performance in terms of functionality, battery durability, compared to other measuring devices, more expensive than our proposal. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11276-021-02799-5. Springer US 2021-10-18 2021 /pmc/articles/PMC8520892/ http://dx.doi.org/10.1007/s11276-021-02799-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Paper Fayos-Jordan, Rafael Segura-Garcia, Jaume Soriano-Asensi, Antonio Felici-Castell, Santiago Felisi, Jose M. Alcaraz-Calero, Jose M. VentQsys: Low-cost open IoT system for [Formula: see text] monitoring in classrooms |
title | VentQsys: Low-cost open IoT system for [Formula: see text] monitoring in classrooms |
title_full | VentQsys: Low-cost open IoT system for [Formula: see text] monitoring in classrooms |
title_fullStr | VentQsys: Low-cost open IoT system for [Formula: see text] monitoring in classrooms |
title_full_unstemmed | VentQsys: Low-cost open IoT system for [Formula: see text] monitoring in classrooms |
title_short | VentQsys: Low-cost open IoT system for [Formula: see text] monitoring in classrooms |
title_sort | ventqsys: low-cost open iot system for [formula: see text] monitoring in classrooms |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8520892/ http://dx.doi.org/10.1007/s11276-021-02799-5 |
work_keys_str_mv | AT fayosjordanrafael ventqsyslowcostopeniotsystemforformulaseetextmonitoringinclassrooms AT seguragarciajaume ventqsyslowcostopeniotsystemforformulaseetextmonitoringinclassrooms AT sorianoasensiantonio ventqsyslowcostopeniotsystemforformulaseetextmonitoringinclassrooms AT felicicastellsantiago ventqsyslowcostopeniotsystemforformulaseetextmonitoringinclassrooms AT felisijosem ventqsyslowcostopeniotsystemforformulaseetextmonitoringinclassrooms AT alcarazcalerojosem ventqsyslowcostopeniotsystemforformulaseetextmonitoringinclassrooms |