Point-of-Care Testing for Multiple Cardiac Markers Based on a Snail-Shaped Microfluidic Chip
Existing methods for detecting cardiac markers are difficult to be applied in point-of-care testing (POCT) due to complex operation, long time consumption, and low sensitivity. Here, we report a snail-shaped microfluidic chip (SMC) for the multiplex detection of cTnI, CK-MB, and Myo with high sensit...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8521045/ https://www.ncbi.nlm.nih.gov/pubmed/34671590 http://dx.doi.org/10.3389/fchem.2021.741058 |
_version_ | 1784584815611215872 |
---|---|
author | Yin, Binfeng Wan, Xinhua Qian, Changcheng Sohan, A. S. M. Muhtasim Fuad Wang, Songbai Zhou, Teng |
author_facet | Yin, Binfeng Wan, Xinhua Qian, Changcheng Sohan, A. S. M. Muhtasim Fuad Wang, Songbai Zhou, Teng |
author_sort | Yin, Binfeng |
collection | PubMed |
description | Existing methods for detecting cardiac markers are difficult to be applied in point-of-care testing (POCT) due to complex operation, long time consumption, and low sensitivity. Here, we report a snail-shaped microfluidic chip (SMC) for the multiplex detection of cTnI, CK-MB, and Myo with high sensitivity and a short detection time. The SMC consists of a sandwich structure: a channel layer with a mixer and reaction zone, a reaction layer coated with capture antibodies, and a base layer. The opening or closing of the microchannels is realized by controlling the downward movement of the press-type mechanical valve. The chemiluminescence method was used as a signal readout, and the experimental conditions were optimized. SMC could detect cTnI, CK-MB, and Myo at concentrations as low as 1.02, 1.37, and 4.15. The SMC will be a promising platform for a simultaneous determination of multianalytes and shows a potential application in POCT. |
format | Online Article Text |
id | pubmed-8521045 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-85210452021-10-19 Point-of-Care Testing for Multiple Cardiac Markers Based on a Snail-Shaped Microfluidic Chip Yin, Binfeng Wan, Xinhua Qian, Changcheng Sohan, A. S. M. Muhtasim Fuad Wang, Songbai Zhou, Teng Front Chem Chemistry Existing methods for detecting cardiac markers are difficult to be applied in point-of-care testing (POCT) due to complex operation, long time consumption, and low sensitivity. Here, we report a snail-shaped microfluidic chip (SMC) for the multiplex detection of cTnI, CK-MB, and Myo with high sensitivity and a short detection time. The SMC consists of a sandwich structure: a channel layer with a mixer and reaction zone, a reaction layer coated with capture antibodies, and a base layer. The opening or closing of the microchannels is realized by controlling the downward movement of the press-type mechanical valve. The chemiluminescence method was used as a signal readout, and the experimental conditions were optimized. SMC could detect cTnI, CK-MB, and Myo at concentrations as low as 1.02, 1.37, and 4.15. The SMC will be a promising platform for a simultaneous determination of multianalytes and shows a potential application in POCT. Frontiers Media S.A. 2021-10-04 /pmc/articles/PMC8521045/ /pubmed/34671590 http://dx.doi.org/10.3389/fchem.2021.741058 Text en Copyright © 2021 Yin, Wan, Qian, Sohan, Wang and Zhou. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Chemistry Yin, Binfeng Wan, Xinhua Qian, Changcheng Sohan, A. S. M. Muhtasim Fuad Wang, Songbai Zhou, Teng Point-of-Care Testing for Multiple Cardiac Markers Based on a Snail-Shaped Microfluidic Chip |
title | Point-of-Care Testing for Multiple Cardiac Markers Based on a Snail-Shaped Microfluidic Chip |
title_full | Point-of-Care Testing for Multiple Cardiac Markers Based on a Snail-Shaped Microfluidic Chip |
title_fullStr | Point-of-Care Testing for Multiple Cardiac Markers Based on a Snail-Shaped Microfluidic Chip |
title_full_unstemmed | Point-of-Care Testing for Multiple Cardiac Markers Based on a Snail-Shaped Microfluidic Chip |
title_short | Point-of-Care Testing for Multiple Cardiac Markers Based on a Snail-Shaped Microfluidic Chip |
title_sort | point-of-care testing for multiple cardiac markers based on a snail-shaped microfluidic chip |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8521045/ https://www.ncbi.nlm.nih.gov/pubmed/34671590 http://dx.doi.org/10.3389/fchem.2021.741058 |
work_keys_str_mv | AT yinbinfeng pointofcaretestingformultiplecardiacmarkersbasedonasnailshapedmicrofluidicchip AT wanxinhua pointofcaretestingformultiplecardiacmarkersbasedonasnailshapedmicrofluidicchip AT qianchangcheng pointofcaretestingformultiplecardiacmarkersbasedonasnailshapedmicrofluidicchip AT sohanasmmuhtasimfuad pointofcaretestingformultiplecardiacmarkersbasedonasnailshapedmicrofluidicchip AT wangsongbai pointofcaretestingformultiplecardiacmarkersbasedonasnailshapedmicrofluidicchip AT zhouteng pointofcaretestingformultiplecardiacmarkersbasedonasnailshapedmicrofluidicchip |