Lysis reagents, cell numbers, and calculation method influence high-throughput measurement of HDL-mediated cholesterol efflux capacity

HDL-mediated cholesterol efflux capacity (CEC) may protect against cardiovascular disease. However, CEC assays are not standardized, hampering their application in large cohorts and comparison between studies. To improve standardization, we systematically investigated technical differences between e...

Descripción completa

Detalles Bibliográficos
Autores principales: Schachtl-Riess, Johanna F., Coassin, Stefan, Lamina, Claudia, Demetz, Egon, Streiter, Gertraud, Hilbe, Richard, Kronenberg, Florian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Society for Biochemistry and Molecular Biology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8521207/
https://www.ncbi.nlm.nih.gov/pubmed/34571016
http://dx.doi.org/10.1016/j.jlr.2021.100125
_version_ 1784584853510946816
author Schachtl-Riess, Johanna F.
Coassin, Stefan
Lamina, Claudia
Demetz, Egon
Streiter, Gertraud
Hilbe, Richard
Kronenberg, Florian
author_facet Schachtl-Riess, Johanna F.
Coassin, Stefan
Lamina, Claudia
Demetz, Egon
Streiter, Gertraud
Hilbe, Richard
Kronenberg, Florian
author_sort Schachtl-Riess, Johanna F.
collection PubMed
description HDL-mediated cholesterol efflux capacity (CEC) may protect against cardiovascular disease. However, CEC assays are not standardized, hampering their application in large cohorts and comparison between studies. To improve standardization, we systematically investigated technical differences between existing protocols that influence assay performance that have not been previously addressed. CEC was measured in 96-well plates using J774A.1 macrophages labeled with BODIPY-cholesterol and incubated for 4 h with 2% apolipoprotein B-depleted human serum. The time zero method, which calculates CEC using control wells, and the per-well method, which calculates CEC based on the actual content of BODIPY-cholesterol in each well, were compared in 506 samples. We showed that the per-well method had a considerably lower sample rejection rate (4.74% vs. 13.44%) and intra-assay (4.48% vs. 5.28%) and interassay coefficients of variation (two controls: 7.85%, 9.86% vs. 13.58%, 15.29%) compared with the time zero method. Correction for plate-to-plate differences using four controls on each plate also improved assay performance of both methods. In addition, we observed that the lysis reagent used had a significant effect. Compared with cholic acid, lysis with sodium hydroxide results in higher (P = 0.0082) and Triton X-100 in lower (P = 0.0028) CEC values. Furthermore, large cell seeding errors (30% variation) greatly biased CEC for both referencing methods (P < 0.0001) as measured by a resazurin assay. In conclusion, lysis reagents, cell numbers, and assay setup greatly impact the quality and reliability of CEC quantification and should be considered when this method is newly established in a laboratory.
format Online
Article
Text
id pubmed-8521207
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher American Society for Biochemistry and Molecular Biology
record_format MEDLINE/PubMed
spelling pubmed-85212072021-10-25 Lysis reagents, cell numbers, and calculation method influence high-throughput measurement of HDL-mediated cholesterol efflux capacity Schachtl-Riess, Johanna F. Coassin, Stefan Lamina, Claudia Demetz, Egon Streiter, Gertraud Hilbe, Richard Kronenberg, Florian J Lipid Res Methods HDL-mediated cholesterol efflux capacity (CEC) may protect against cardiovascular disease. However, CEC assays are not standardized, hampering their application in large cohorts and comparison between studies. To improve standardization, we systematically investigated technical differences between existing protocols that influence assay performance that have not been previously addressed. CEC was measured in 96-well plates using J774A.1 macrophages labeled with BODIPY-cholesterol and incubated for 4 h with 2% apolipoprotein B-depleted human serum. The time zero method, which calculates CEC using control wells, and the per-well method, which calculates CEC based on the actual content of BODIPY-cholesterol in each well, were compared in 506 samples. We showed that the per-well method had a considerably lower sample rejection rate (4.74% vs. 13.44%) and intra-assay (4.48% vs. 5.28%) and interassay coefficients of variation (two controls: 7.85%, 9.86% vs. 13.58%, 15.29%) compared with the time zero method. Correction for plate-to-plate differences using four controls on each plate also improved assay performance of both methods. In addition, we observed that the lysis reagent used had a significant effect. Compared with cholic acid, lysis with sodium hydroxide results in higher (P = 0.0082) and Triton X-100 in lower (P = 0.0028) CEC values. Furthermore, large cell seeding errors (30% variation) greatly biased CEC for both referencing methods (P < 0.0001) as measured by a resazurin assay. In conclusion, lysis reagents, cell numbers, and assay setup greatly impact the quality and reliability of CEC quantification and should be considered when this method is newly established in a laboratory. American Society for Biochemistry and Molecular Biology 2021-09-25 /pmc/articles/PMC8521207/ /pubmed/34571016 http://dx.doi.org/10.1016/j.jlr.2021.100125 Text en © 2021 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Methods
Schachtl-Riess, Johanna F.
Coassin, Stefan
Lamina, Claudia
Demetz, Egon
Streiter, Gertraud
Hilbe, Richard
Kronenberg, Florian
Lysis reagents, cell numbers, and calculation method influence high-throughput measurement of HDL-mediated cholesterol efflux capacity
title Lysis reagents, cell numbers, and calculation method influence high-throughput measurement of HDL-mediated cholesterol efflux capacity
title_full Lysis reagents, cell numbers, and calculation method influence high-throughput measurement of HDL-mediated cholesterol efflux capacity
title_fullStr Lysis reagents, cell numbers, and calculation method influence high-throughput measurement of HDL-mediated cholesterol efflux capacity
title_full_unstemmed Lysis reagents, cell numbers, and calculation method influence high-throughput measurement of HDL-mediated cholesterol efflux capacity
title_short Lysis reagents, cell numbers, and calculation method influence high-throughput measurement of HDL-mediated cholesterol efflux capacity
title_sort lysis reagents, cell numbers, and calculation method influence high-throughput measurement of hdl-mediated cholesterol efflux capacity
topic Methods
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8521207/
https://www.ncbi.nlm.nih.gov/pubmed/34571016
http://dx.doi.org/10.1016/j.jlr.2021.100125
work_keys_str_mv AT schachtlriessjohannaf lysisreagentscellnumbersandcalculationmethodinfluencehighthroughputmeasurementofhdlmediatedcholesteroleffluxcapacity
AT coassinstefan lysisreagentscellnumbersandcalculationmethodinfluencehighthroughputmeasurementofhdlmediatedcholesteroleffluxcapacity
AT laminaclaudia lysisreagentscellnumbersandcalculationmethodinfluencehighthroughputmeasurementofhdlmediatedcholesteroleffluxcapacity
AT demetzegon lysisreagentscellnumbersandcalculationmethodinfluencehighthroughputmeasurementofhdlmediatedcholesteroleffluxcapacity
AT streitergertraud lysisreagentscellnumbersandcalculationmethodinfluencehighthroughputmeasurementofhdlmediatedcholesteroleffluxcapacity
AT hilberichard lysisreagentscellnumbersandcalculationmethodinfluencehighthroughputmeasurementofhdlmediatedcholesteroleffluxcapacity
AT kronenbergflorian lysisreagentscellnumbersandcalculationmethodinfluencehighthroughputmeasurementofhdlmediatedcholesteroleffluxcapacity