Quantitative assessment of velocity and flow using compressed SENSE in children and young adults with adequate acquired temporal resolution

BACKGROUND: Phase contrast (PC) cardiovascular magnetic resonance (CMR) imaging with parallel imaging acceleration is established and validated for measuring velocity and flow. However, additional acceleration to further shorten acquisition times would be beneficial in patients with complex vasculat...

Descripción completa

Detalles Bibliográficos
Autores principales: Kocaoglu, Murat, Pednekar, Amol, Tkach, Jean A., Taylor, Michael D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8522244/
https://www.ncbi.nlm.nih.gov/pubmed/34663351
http://dx.doi.org/10.1186/s12968-021-00811-7
_version_ 1784585053320249344
author Kocaoglu, Murat
Pednekar, Amol
Tkach, Jean A.
Taylor, Michael D.
author_facet Kocaoglu, Murat
Pednekar, Amol
Tkach, Jean A.
Taylor, Michael D.
author_sort Kocaoglu, Murat
collection PubMed
description BACKGROUND: Phase contrast (PC) cardiovascular magnetic resonance (CMR) imaging with parallel imaging acceleration is established and validated for measuring velocity and flow. However, additional acceleration to further shorten acquisition times would be beneficial in patients with complex vasculature who need multiple PC-CMR measurements, especially pediatric patients with higher heart rates. METHODS: PC-CMR images acquired with compressed sensitivity encoding (C-SENSE) factors of 3 to 6 and standard of care PC-CMR with sensitivity encoding (SENSE) factor of 2 (S2) acquired as part of clinical CMR examinations performed between November 2020 and January 2021 were analyzed retrospectively. The velocity and flow through the ascending aorta (AAo), descending aorta (DAo), and superior vena cava (SVC) in a transverse plane at the level of pulmonary artery bifurcation were compared. Additionally, frequency power distribution and dynamic time warp distance were calculated for these acquisitions. To further validate the adequate temporal resolution requirement, patients with S2 PC-CMR in the same acquisition plane were added in frequency power distribution analysis. RESULTS: Twenty-eight patients (25 males; 15.9 ± 1.9 years; body surface area (BSA) 1.7 ± 0.2 m(2); heart rate 81 ± 16 bpm) underwent all five PC-CMR acquisitions during the study period. An additional 22 patients (16 males; 17.5 ± 7.7 years; BSA 1.6 ± 0.5 m(2); heart rate 91 ± 16 bpm) were included for frequency power spectrum analysis. As expected, scan time decreased with increasing C-SENSE acceleration factor = 3 (37.5 ± 6.5 s, 26.4 ± 7.6%), 4 (28.1 ± 4.9 s, 44.7 ± 5.6%), 5 (21.6 ± 3.6 s, 57.6 ± 4.4%), and 6 (19.1 ± 3.2 s, 62.3 ± 4.2%) relative to SENSE = 2 (51.3 ± 10.1 s) PC-CMR acquisition. Mean peak velocity, net flow, and cardiac output were comparable (p > 0.87) between the five PC-CMR acquisitions with mean differences less than < 4%, < 2%, and < 3% respectively. All individual blood vessels showed a non-significant dependence of difference in f(max99) (< 4 Hz, p > 0.2), and dynamic time warp distance (p > 0.3) on the C-SENSE acceleration factor used. There was a strongly correlated (r = 0.74) increase in f(max99) (10.5 ± 2.2, range: 7.1–16.4 Hz) with increasing heart rate. The computed minimum required cardiac phase number was 15 ± 2.0 (range: 11–20) over the heart rate of 86 ± 15 bpm (range: 58–113 bpm). CONCLUSIONS: Stroke volume, cardiac output, and mean peak velocity measurements using PC-CMR with C-SENSE of up to 6 agree with measurements by standard of care PC-CMR with SENSE = 2 and resulted in up to a 65% reduction in acquisition time. Adequate temporal sampling can be ensured by acquiring 20 cardiac phases throughout the entire cardiac cycle over a wide range of pediatric and young adult heart rates.
format Online
Article
Text
id pubmed-8522244
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-85222442021-10-22 Quantitative assessment of velocity and flow using compressed SENSE in children and young adults with adequate acquired temporal resolution Kocaoglu, Murat Pednekar, Amol Tkach, Jean A. Taylor, Michael D. J Cardiovasc Magn Reson Research BACKGROUND: Phase contrast (PC) cardiovascular magnetic resonance (CMR) imaging with parallel imaging acceleration is established and validated for measuring velocity and flow. However, additional acceleration to further shorten acquisition times would be beneficial in patients with complex vasculature who need multiple PC-CMR measurements, especially pediatric patients with higher heart rates. METHODS: PC-CMR images acquired with compressed sensitivity encoding (C-SENSE) factors of 3 to 6 and standard of care PC-CMR with sensitivity encoding (SENSE) factor of 2 (S2) acquired as part of clinical CMR examinations performed between November 2020 and January 2021 were analyzed retrospectively. The velocity and flow through the ascending aorta (AAo), descending aorta (DAo), and superior vena cava (SVC) in a transverse plane at the level of pulmonary artery bifurcation were compared. Additionally, frequency power distribution and dynamic time warp distance were calculated for these acquisitions. To further validate the adequate temporal resolution requirement, patients with S2 PC-CMR in the same acquisition plane were added in frequency power distribution analysis. RESULTS: Twenty-eight patients (25 males; 15.9 ± 1.9 years; body surface area (BSA) 1.7 ± 0.2 m(2); heart rate 81 ± 16 bpm) underwent all five PC-CMR acquisitions during the study period. An additional 22 patients (16 males; 17.5 ± 7.7 years; BSA 1.6 ± 0.5 m(2); heart rate 91 ± 16 bpm) were included for frequency power spectrum analysis. As expected, scan time decreased with increasing C-SENSE acceleration factor = 3 (37.5 ± 6.5 s, 26.4 ± 7.6%), 4 (28.1 ± 4.9 s, 44.7 ± 5.6%), 5 (21.6 ± 3.6 s, 57.6 ± 4.4%), and 6 (19.1 ± 3.2 s, 62.3 ± 4.2%) relative to SENSE = 2 (51.3 ± 10.1 s) PC-CMR acquisition. Mean peak velocity, net flow, and cardiac output were comparable (p > 0.87) between the five PC-CMR acquisitions with mean differences less than < 4%, < 2%, and < 3% respectively. All individual blood vessels showed a non-significant dependence of difference in f(max99) (< 4 Hz, p > 0.2), and dynamic time warp distance (p > 0.3) on the C-SENSE acceleration factor used. There was a strongly correlated (r = 0.74) increase in f(max99) (10.5 ± 2.2, range: 7.1–16.4 Hz) with increasing heart rate. The computed minimum required cardiac phase number was 15 ± 2.0 (range: 11–20) over the heart rate of 86 ± 15 bpm (range: 58–113 bpm). CONCLUSIONS: Stroke volume, cardiac output, and mean peak velocity measurements using PC-CMR with C-SENSE of up to 6 agree with measurements by standard of care PC-CMR with SENSE = 2 and resulted in up to a 65% reduction in acquisition time. Adequate temporal sampling can be ensured by acquiring 20 cardiac phases throughout the entire cardiac cycle over a wide range of pediatric and young adult heart rates. BioMed Central 2021-10-18 /pmc/articles/PMC8522244/ /pubmed/34663351 http://dx.doi.org/10.1186/s12968-021-00811-7 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Kocaoglu, Murat
Pednekar, Amol
Tkach, Jean A.
Taylor, Michael D.
Quantitative assessment of velocity and flow using compressed SENSE in children and young adults with adequate acquired temporal resolution
title Quantitative assessment of velocity and flow using compressed SENSE in children and young adults with adequate acquired temporal resolution
title_full Quantitative assessment of velocity and flow using compressed SENSE in children and young adults with adequate acquired temporal resolution
title_fullStr Quantitative assessment of velocity and flow using compressed SENSE in children and young adults with adequate acquired temporal resolution
title_full_unstemmed Quantitative assessment of velocity and flow using compressed SENSE in children and young adults with adequate acquired temporal resolution
title_short Quantitative assessment of velocity and flow using compressed SENSE in children and young adults with adequate acquired temporal resolution
title_sort quantitative assessment of velocity and flow using compressed sense in children and young adults with adequate acquired temporal resolution
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8522244/
https://www.ncbi.nlm.nih.gov/pubmed/34663351
http://dx.doi.org/10.1186/s12968-021-00811-7
work_keys_str_mv AT kocaoglumurat quantitativeassessmentofvelocityandflowusingcompressedsenseinchildrenandyoungadultswithadequateacquiredtemporalresolution
AT pednekaramol quantitativeassessmentofvelocityandflowusingcompressedsenseinchildrenandyoungadultswithadequateacquiredtemporalresolution
AT tkachjeana quantitativeassessmentofvelocityandflowusingcompressedsenseinchildrenandyoungadultswithadequateacquiredtemporalresolution
AT taylormichaeld quantitativeassessmentofvelocityandflowusingcompressedsenseinchildrenandyoungadultswithadequateacquiredtemporalresolution