Cargando…
Prevalence and Significance of Patient Prosthesis Mismatch Following Edwards SAPIEN XT and SAPIEN 3 Transcatheter Aortic Valve Replacement
Background Severe patient prosthesis mismatch (sPPM) after surgical aortic valve replacement is associated with worse outcomes. Limited data exists on the impact of sPPM on outcomes after transcatheter aortic valve replacement (TAVR), especially regarding the newer generation valves. The aim of this...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8523339/ https://www.ncbi.nlm.nih.gov/pubmed/34692277 http://dx.doi.org/10.7759/cureus.18044 |
_version_ | 1784585281233485824 |
---|---|
author | Vallabhaneni, Srilakshmi Matka, Marsel Modi, Vivek Carey, Matthew Sarnoski, Christopher Durkin, Raymond Olenchock, Stephen Razzaghi, Mehdi Shirani, Jamshid |
author_facet | Vallabhaneni, Srilakshmi Matka, Marsel Modi, Vivek Carey, Matthew Sarnoski, Christopher Durkin, Raymond Olenchock, Stephen Razzaghi, Mehdi Shirani, Jamshid |
author_sort | Vallabhaneni, Srilakshmi |
collection | PubMed |
description | Background Severe patient prosthesis mismatch (sPPM) after surgical aortic valve replacement is associated with worse outcomes. Limited data exists on the impact of sPPM on outcomes after transcatheter aortic valve replacement (TAVR), especially regarding the newer generation valves. The aim of this study was to evaluate the incidence, determinants, and outcomes of sPPM in patients undergoing TAVR with Edwards SAPIEN XT (ES XT) and Edwards SAPIEN 3 (ES3) valves (Edwards Lifesciences, Irvine, CA, USA). Methods We retrospectively reviewed 366 patients who underwent TAVR with ES XT (n = 114) or ES3 (n = 252) valves between July 2012 and June 2018. sPPM was defined as indexed effective orifice area (iEOA) <0.65 cm(2)/m(2). Kaplan-Meier survival estimates were used to determine outcomes. Results Multivariate linear regression analysis was utilized to determine potential independent effects of PPM on outcomes. sPPM was present in 40 (11%) of the patients [8 (7%) ES XT and 32 (13%) ES3] and was associated with female sex, smaller left ventricular outflow tract (LVOT) diameter and aortic valve annular area, absence of prior coronary artery bypass graft (CABG) surgery, shorter height, higher body mass index, and smaller pre-TAVR valve area (all p < 0.05). Among those with ES3 valves, the incidence of sPPM was inversely proportional to the valve size (50%, 25%, 5% and 3% for 20-, 23-, 26- and 29-mm valve sizes, respectively; p < 0.001). At a mean follow-up period of 3.5 ± 1.5 years, there was no difference in all-cause mortality (22.5% vs. 25.6%, p = 0.89) or a composite endpoint of heart failure, arrhythmias, stroke, and myocardial infarction (30% vs. 34%, p = 0.24) in those with or without sPPM. Conclusion ES3 was associated with a higher incidence of sPPM, particularly with smaller valve sizes. However, the presence of sPPM as defined by iEOA was not an independent predictor of adverse outcomes in patients undergoing TAVR within an intermediate follow-up period. |
format | Online Article Text |
id | pubmed-8523339 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-85233392021-10-22 Prevalence and Significance of Patient Prosthesis Mismatch Following Edwards SAPIEN XT and SAPIEN 3 Transcatheter Aortic Valve Replacement Vallabhaneni, Srilakshmi Matka, Marsel Modi, Vivek Carey, Matthew Sarnoski, Christopher Durkin, Raymond Olenchock, Stephen Razzaghi, Mehdi Shirani, Jamshid Cureus Cardiac/Thoracic/Vascular Surgery Background Severe patient prosthesis mismatch (sPPM) after surgical aortic valve replacement is associated with worse outcomes. Limited data exists on the impact of sPPM on outcomes after transcatheter aortic valve replacement (TAVR), especially regarding the newer generation valves. The aim of this study was to evaluate the incidence, determinants, and outcomes of sPPM in patients undergoing TAVR with Edwards SAPIEN XT (ES XT) and Edwards SAPIEN 3 (ES3) valves (Edwards Lifesciences, Irvine, CA, USA). Methods We retrospectively reviewed 366 patients who underwent TAVR with ES XT (n = 114) or ES3 (n = 252) valves between July 2012 and June 2018. sPPM was defined as indexed effective orifice area (iEOA) <0.65 cm(2)/m(2). Kaplan-Meier survival estimates were used to determine outcomes. Results Multivariate linear regression analysis was utilized to determine potential independent effects of PPM on outcomes. sPPM was present in 40 (11%) of the patients [8 (7%) ES XT and 32 (13%) ES3] and was associated with female sex, smaller left ventricular outflow tract (LVOT) diameter and aortic valve annular area, absence of prior coronary artery bypass graft (CABG) surgery, shorter height, higher body mass index, and smaller pre-TAVR valve area (all p < 0.05). Among those with ES3 valves, the incidence of sPPM was inversely proportional to the valve size (50%, 25%, 5% and 3% for 20-, 23-, 26- and 29-mm valve sizes, respectively; p < 0.001). At a mean follow-up period of 3.5 ± 1.5 years, there was no difference in all-cause mortality (22.5% vs. 25.6%, p = 0.89) or a composite endpoint of heart failure, arrhythmias, stroke, and myocardial infarction (30% vs. 34%, p = 0.24) in those with or without sPPM. Conclusion ES3 was associated with a higher incidence of sPPM, particularly with smaller valve sizes. However, the presence of sPPM as defined by iEOA was not an independent predictor of adverse outcomes in patients undergoing TAVR within an intermediate follow-up period. Cureus 2021-09-17 /pmc/articles/PMC8523339/ /pubmed/34692277 http://dx.doi.org/10.7759/cureus.18044 Text en Copyright © 2021, Vallabhaneni et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Cardiac/Thoracic/Vascular Surgery Vallabhaneni, Srilakshmi Matka, Marsel Modi, Vivek Carey, Matthew Sarnoski, Christopher Durkin, Raymond Olenchock, Stephen Razzaghi, Mehdi Shirani, Jamshid Prevalence and Significance of Patient Prosthesis Mismatch Following Edwards SAPIEN XT and SAPIEN 3 Transcatheter Aortic Valve Replacement |
title | Prevalence and Significance of Patient Prosthesis Mismatch Following Edwards SAPIEN XT and SAPIEN 3 Transcatheter Aortic Valve Replacement |
title_full | Prevalence and Significance of Patient Prosthesis Mismatch Following Edwards SAPIEN XT and SAPIEN 3 Transcatheter Aortic Valve Replacement |
title_fullStr | Prevalence and Significance of Patient Prosthesis Mismatch Following Edwards SAPIEN XT and SAPIEN 3 Transcatheter Aortic Valve Replacement |
title_full_unstemmed | Prevalence and Significance of Patient Prosthesis Mismatch Following Edwards SAPIEN XT and SAPIEN 3 Transcatheter Aortic Valve Replacement |
title_short | Prevalence and Significance of Patient Prosthesis Mismatch Following Edwards SAPIEN XT and SAPIEN 3 Transcatheter Aortic Valve Replacement |
title_sort | prevalence and significance of patient prosthesis mismatch following edwards sapien xt and sapien 3 transcatheter aortic valve replacement |
topic | Cardiac/Thoracic/Vascular Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8523339/ https://www.ncbi.nlm.nih.gov/pubmed/34692277 http://dx.doi.org/10.7759/cureus.18044 |
work_keys_str_mv | AT vallabhanenisrilakshmi prevalenceandsignificanceofpatientprosthesismismatchfollowingedwardssapienxtandsapien3transcatheteraorticvalvereplacement AT matkamarsel prevalenceandsignificanceofpatientprosthesismismatchfollowingedwardssapienxtandsapien3transcatheteraorticvalvereplacement AT modivivek prevalenceandsignificanceofpatientprosthesismismatchfollowingedwardssapienxtandsapien3transcatheteraorticvalvereplacement AT careymatthew prevalenceandsignificanceofpatientprosthesismismatchfollowingedwardssapienxtandsapien3transcatheteraorticvalvereplacement AT sarnoskichristopher prevalenceandsignificanceofpatientprosthesismismatchfollowingedwardssapienxtandsapien3transcatheteraorticvalvereplacement AT durkinraymond prevalenceandsignificanceofpatientprosthesismismatchfollowingedwardssapienxtandsapien3transcatheteraorticvalvereplacement AT olenchockstephen prevalenceandsignificanceofpatientprosthesismismatchfollowingedwardssapienxtandsapien3transcatheteraorticvalvereplacement AT razzaghimehdi prevalenceandsignificanceofpatientprosthesismismatchfollowingedwardssapienxtandsapien3transcatheteraorticvalvereplacement AT shiranijamshid prevalenceandsignificanceofpatientprosthesismismatchfollowingedwardssapienxtandsapien3transcatheteraorticvalvereplacement |