Cargando…
Public toilets with insufficient ventilation present high cross infection risk
Due to insufficient ventilation, public toilets present high risks for cross-infection. The study investigated 61 public toilets to identify the causes and locations of biological contaminated sources. Airborne and surface bacterial contamination, carbon dioxide concentration, and surface ammonia le...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8523564/ https://www.ncbi.nlm.nih.gov/pubmed/34663838 http://dx.doi.org/10.1038/s41598-021-00166-0 |
_version_ | 1784585329507827712 |
---|---|
author | Lee, M. C. Jeffrey Tham, K. W. |
author_facet | Lee, M. C. Jeffrey Tham, K. W. |
author_sort | Lee, M. C. Jeffrey |
collection | PubMed |
description | Due to insufficient ventilation, public toilets present high risks for cross-infection. The study investigated 61 public toilets to identify the causes and locations of biological contaminated sources. Airborne and surface bacterial contamination, carbon dioxide concentration, and surface ammonia levels were measured. Both bacterial contamination and CO(2) are higher in non-ventilated toilets compared to their ventilated counterparts. Bacteria colony forming units (CFUs) in a public toilet with poor ventilation can reach 5 times the number of CFUs outside of the toilet. This suggests that non-ventilated public toilets present a higher risk of cross-infection. Areas near all kinds of sanitary equipment (toilet bowls, squat toilets and urinals) were highly contaminated, indicating that enhanced cleaning regimes are necessary. Further, lidless trash bins present a higher risk as contaminated matter within the trash bins is not inhibited from being released into the environment. Ventilation and cleaning need to be improved to mitigate the risk of cross-infection in public toilets. |
format | Online Article Text |
id | pubmed-8523564 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-85235642021-10-20 Public toilets with insufficient ventilation present high cross infection risk Lee, M. C. Jeffrey Tham, K. W. Sci Rep Article Due to insufficient ventilation, public toilets present high risks for cross-infection. The study investigated 61 public toilets to identify the causes and locations of biological contaminated sources. Airborne and surface bacterial contamination, carbon dioxide concentration, and surface ammonia levels were measured. Both bacterial contamination and CO(2) are higher in non-ventilated toilets compared to their ventilated counterparts. Bacteria colony forming units (CFUs) in a public toilet with poor ventilation can reach 5 times the number of CFUs outside of the toilet. This suggests that non-ventilated public toilets present a higher risk of cross-infection. Areas near all kinds of sanitary equipment (toilet bowls, squat toilets and urinals) were highly contaminated, indicating that enhanced cleaning regimes are necessary. Further, lidless trash bins present a higher risk as contaminated matter within the trash bins is not inhibited from being released into the environment. Ventilation and cleaning need to be improved to mitigate the risk of cross-infection in public toilets. Nature Publishing Group UK 2021-10-18 /pmc/articles/PMC8523564/ /pubmed/34663838 http://dx.doi.org/10.1038/s41598-021-00166-0 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Lee, M. C. Jeffrey Tham, K. W. Public toilets with insufficient ventilation present high cross infection risk |
title | Public toilets with insufficient ventilation present high cross infection risk |
title_full | Public toilets with insufficient ventilation present high cross infection risk |
title_fullStr | Public toilets with insufficient ventilation present high cross infection risk |
title_full_unstemmed | Public toilets with insufficient ventilation present high cross infection risk |
title_short | Public toilets with insufficient ventilation present high cross infection risk |
title_sort | public toilets with insufficient ventilation present high cross infection risk |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8523564/ https://www.ncbi.nlm.nih.gov/pubmed/34663838 http://dx.doi.org/10.1038/s41598-021-00166-0 |
work_keys_str_mv | AT leemcjeffrey publictoiletswithinsufficientventilationpresenthighcrossinfectionrisk AT thamkw publictoiletswithinsufficientventilationpresenthighcrossinfectionrisk |