Comparison of surgically induced astigmatism between anterior and total cornea in 2.2 mm steep meridian incision cataract surgery
BACKGROUND: This study aimed to compare surgically induced astigmatism (SIA) on the anterior and total cornea during cataract surgery through a 2.2 mm steep meridian incision. METHODS: The study included 69 left eyes of 69 patients who had undergone cataract surgery. The 69 eyes were classified into...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8524831/ https://www.ncbi.nlm.nih.gov/pubmed/34666720 http://dx.doi.org/10.1186/s12886-021-02131-x |
_version_ | 1784585554508120064 |
---|---|
author | Yoon, Young-chae Ha, Minji Whang, Woong-Joo |
author_facet | Yoon, Young-chae Ha, Minji Whang, Woong-Joo |
author_sort | Yoon, Young-chae |
collection | PubMed |
description | BACKGROUND: This study aimed to compare surgically induced astigmatism (SIA) on the anterior and total cornea during cataract surgery through a 2.2 mm steep meridian incision. METHODS: The study included 69 left eyes of 69 patients who had undergone cataract surgery. The 69 eyes were classified into three subgroups according to the preoperative steep meridian. Following phacoemulsification, an intraocular lens was inserted into the bag. The keratometric measurements were taken 12 months postoperatively, on the anterior cornea (automated keratometer and anterior keratometry [K] from a rotating Scheimpflug camera) and total cornea (equivalent K reading [EKR] 3.0 mm, EKR 4.5 mm, total corneal refractive power (TCRP) 2.0 mm ring, TCRP 3.0 mm zone, TCRP 4.0 mm zone). The SIA was analyzed for each parameter. RESULTS: On the double-angle polar plot, the summated vector mean values of SIA determined by the automated keratometer and Scheimpflug anterior K were 0.28 diopter (axis: 177°) and 0.37 diopter (axis: 175°) in with-the-rule (WTR) astigmatism; 0.03 diopter (axis: 156°) and 0.18 diopter (axis: 177°) in oblique astigmatism; 0.15 diopter (axis: 96°) and 0.17 diopter (axis: 73°) in against-the-rule (ATR) astigmatism. The mean SIAs on the total cornea ranged from 0.31 to 0.42 diopter in WTR astigmatism; from 0.16 to 0.27 diopter in oblique astigmatism; from 0.04 to 0.11 diopter in ATR astigmatism. Mean magnitude SIA ranged from 0.41 to 0.46 diopter on anterior corneal surface and 0.50 to 0.62 diopter on total cornea. J(0) and J(45) of the posterior cornea showed no significant changes after cataract surgery, and the changes in J(0) and J(45) did not show any statistical differences between the anterior and total cornea (all p > 0.05). CONCLUSIONS: There were no differences in the summed vector mean values of SIA between the anterior cornea and the total cornea. |
format | Online Article Text |
id | pubmed-8524831 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-85248312021-10-22 Comparison of surgically induced astigmatism between anterior and total cornea in 2.2 mm steep meridian incision cataract surgery Yoon, Young-chae Ha, Minji Whang, Woong-Joo BMC Ophthalmol Research Article BACKGROUND: This study aimed to compare surgically induced astigmatism (SIA) on the anterior and total cornea during cataract surgery through a 2.2 mm steep meridian incision. METHODS: The study included 69 left eyes of 69 patients who had undergone cataract surgery. The 69 eyes were classified into three subgroups according to the preoperative steep meridian. Following phacoemulsification, an intraocular lens was inserted into the bag. The keratometric measurements were taken 12 months postoperatively, on the anterior cornea (automated keratometer and anterior keratometry [K] from a rotating Scheimpflug camera) and total cornea (equivalent K reading [EKR] 3.0 mm, EKR 4.5 mm, total corneal refractive power (TCRP) 2.0 mm ring, TCRP 3.0 mm zone, TCRP 4.0 mm zone). The SIA was analyzed for each parameter. RESULTS: On the double-angle polar plot, the summated vector mean values of SIA determined by the automated keratometer and Scheimpflug anterior K were 0.28 diopter (axis: 177°) and 0.37 diopter (axis: 175°) in with-the-rule (WTR) astigmatism; 0.03 diopter (axis: 156°) and 0.18 diopter (axis: 177°) in oblique astigmatism; 0.15 diopter (axis: 96°) and 0.17 diopter (axis: 73°) in against-the-rule (ATR) astigmatism. The mean SIAs on the total cornea ranged from 0.31 to 0.42 diopter in WTR astigmatism; from 0.16 to 0.27 diopter in oblique astigmatism; from 0.04 to 0.11 diopter in ATR astigmatism. Mean magnitude SIA ranged from 0.41 to 0.46 diopter on anterior corneal surface and 0.50 to 0.62 diopter on total cornea. J(0) and J(45) of the posterior cornea showed no significant changes after cataract surgery, and the changes in J(0) and J(45) did not show any statistical differences between the anterior and total cornea (all p > 0.05). CONCLUSIONS: There were no differences in the summed vector mean values of SIA between the anterior cornea and the total cornea. BioMed Central 2021-10-19 /pmc/articles/PMC8524831/ /pubmed/34666720 http://dx.doi.org/10.1186/s12886-021-02131-x Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Yoon, Young-chae Ha, Minji Whang, Woong-Joo Comparison of surgically induced astigmatism between anterior and total cornea in 2.2 mm steep meridian incision cataract surgery |
title | Comparison of surgically induced astigmatism between anterior and total cornea in 2.2 mm steep meridian incision cataract surgery |
title_full | Comparison of surgically induced astigmatism between anterior and total cornea in 2.2 mm steep meridian incision cataract surgery |
title_fullStr | Comparison of surgically induced astigmatism between anterior and total cornea in 2.2 mm steep meridian incision cataract surgery |
title_full_unstemmed | Comparison of surgically induced astigmatism between anterior and total cornea in 2.2 mm steep meridian incision cataract surgery |
title_short | Comparison of surgically induced astigmatism between anterior and total cornea in 2.2 mm steep meridian incision cataract surgery |
title_sort | comparison of surgically induced astigmatism between anterior and total cornea in 2.2 mm steep meridian incision cataract surgery |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8524831/ https://www.ncbi.nlm.nih.gov/pubmed/34666720 http://dx.doi.org/10.1186/s12886-021-02131-x |
work_keys_str_mv | AT yoonyoungchae comparisonofsurgicallyinducedastigmatismbetweenanteriorandtotalcorneain22mmsteepmeridianincisioncataractsurgery AT haminji comparisonofsurgicallyinducedastigmatismbetweenanteriorandtotalcorneain22mmsteepmeridianincisioncataractsurgery AT whangwoongjoo comparisonofsurgicallyinducedastigmatismbetweenanteriorandtotalcorneain22mmsteepmeridianincisioncataractsurgery |