Cargando…

Plasma levels of D-dimer and fibrin degradation product are unreliable for diagnosing periprosthetic joint infection in patients undergoing re-revision arthroplasty

BACKGROUND: The preoperative diagnosis of periprosthetic joint infection (PJI) in patients undergoing re-revision arthroplasty is crucial, so we evaluated whether plasma levels of D-dimer and fibrin degradation product (FDP) could aid such diagnosis. METHODS: We retrospectively analyzed data on pati...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Hong, Xie, Jinwei, Wang, Duan, Huang, Qiang, Huang, Zeyu, Zhou, Zongke
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8524877/
https://www.ncbi.nlm.nih.gov/pubmed/34666806
http://dx.doi.org/10.1186/s13018-021-02764-0
_version_ 1784585563683160064
author Xu, Hong
Xie, Jinwei
Wang, Duan
Huang, Qiang
Huang, Zeyu
Zhou, Zongke
author_facet Xu, Hong
Xie, Jinwei
Wang, Duan
Huang, Qiang
Huang, Zeyu
Zhou, Zongke
author_sort Xu, Hong
collection PubMed
description BACKGROUND: The preoperative diagnosis of periprosthetic joint infection (PJI) in patients undergoing re-revision arthroplasty is crucial, so we evaluated whether plasma levels of D-dimer and fibrin degradation product (FDP) could aid such diagnosis. METHODS: We retrospectively analyzed data on patients who underwent re-revision hip or knee arthroplasty at our institute during 2008–2020. Patients were stratified into those who experienced PJI or not, based on 2013 International Consensus Meeting Criteria. Plasma levels of D-dimer and FDP as well as levels of the traditional inflammatory biomarkers C-reactive protein (CRP), erythrocyte sedimentation rate (ESR) and interleukin-6 were compared between the groups. The ability of these biomarkers to diagnose PJI was assessed based on the area under the receiver operating characteristic (AUC) curve, for which predictive cut-offs were optimized based on the Youden index. RESULTS: Based on a cut-off of 0.80 mg/L, D-dimer gave an AUC of 0.595, high sensitivity of 85.7% but poor specificity of 47.8%. Based on a cut-off of 2.80 mg/L, FDP gave an AUC of 0.550, poor sensitivity of 56.5% and poor specificity of 52.9%. CRP, ESR and interleukin-6 showed much better diagnostic ability, with AUCs > 0.82. The combination of CRP and interleukin-6 gave an AUC of 0.877, high sensitivity of 91.7% and acceptable specificity of 78.3%. CONCLUSIONS: Plasma levels of D-dimer and FDP may be inappropriate for diagnosing PJI in patients undergoing re-revision arthroplasty, whereas the combination of serum CRP and interleukin-6 may be effective.
format Online
Article
Text
id pubmed-8524877
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-85248772021-10-22 Plasma levels of D-dimer and fibrin degradation product are unreliable for diagnosing periprosthetic joint infection in patients undergoing re-revision arthroplasty Xu, Hong Xie, Jinwei Wang, Duan Huang, Qiang Huang, Zeyu Zhou, Zongke J Orthop Surg Res Research Article BACKGROUND: The preoperative diagnosis of periprosthetic joint infection (PJI) in patients undergoing re-revision arthroplasty is crucial, so we evaluated whether plasma levels of D-dimer and fibrin degradation product (FDP) could aid such diagnosis. METHODS: We retrospectively analyzed data on patients who underwent re-revision hip or knee arthroplasty at our institute during 2008–2020. Patients were stratified into those who experienced PJI or not, based on 2013 International Consensus Meeting Criteria. Plasma levels of D-dimer and FDP as well as levels of the traditional inflammatory biomarkers C-reactive protein (CRP), erythrocyte sedimentation rate (ESR) and interleukin-6 were compared between the groups. The ability of these biomarkers to diagnose PJI was assessed based on the area under the receiver operating characteristic (AUC) curve, for which predictive cut-offs were optimized based on the Youden index. RESULTS: Based on a cut-off of 0.80 mg/L, D-dimer gave an AUC of 0.595, high sensitivity of 85.7% but poor specificity of 47.8%. Based on a cut-off of 2.80 mg/L, FDP gave an AUC of 0.550, poor sensitivity of 56.5% and poor specificity of 52.9%. CRP, ESR and interleukin-6 showed much better diagnostic ability, with AUCs > 0.82. The combination of CRP and interleukin-6 gave an AUC of 0.877, high sensitivity of 91.7% and acceptable specificity of 78.3%. CONCLUSIONS: Plasma levels of D-dimer and FDP may be inappropriate for diagnosing PJI in patients undergoing re-revision arthroplasty, whereas the combination of serum CRP and interleukin-6 may be effective. BioMed Central 2021-10-19 /pmc/articles/PMC8524877/ /pubmed/34666806 http://dx.doi.org/10.1186/s13018-021-02764-0 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Xu, Hong
Xie, Jinwei
Wang, Duan
Huang, Qiang
Huang, Zeyu
Zhou, Zongke
Plasma levels of D-dimer and fibrin degradation product are unreliable for diagnosing periprosthetic joint infection in patients undergoing re-revision arthroplasty
title Plasma levels of D-dimer and fibrin degradation product are unreliable for diagnosing periprosthetic joint infection in patients undergoing re-revision arthroplasty
title_full Plasma levels of D-dimer and fibrin degradation product are unreliable for diagnosing periprosthetic joint infection in patients undergoing re-revision arthroplasty
title_fullStr Plasma levels of D-dimer and fibrin degradation product are unreliable for diagnosing periprosthetic joint infection in patients undergoing re-revision arthroplasty
title_full_unstemmed Plasma levels of D-dimer and fibrin degradation product are unreliable for diagnosing periprosthetic joint infection in patients undergoing re-revision arthroplasty
title_short Plasma levels of D-dimer and fibrin degradation product are unreliable for diagnosing periprosthetic joint infection in patients undergoing re-revision arthroplasty
title_sort plasma levels of d-dimer and fibrin degradation product are unreliable for diagnosing periprosthetic joint infection in patients undergoing re-revision arthroplasty
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8524877/
https://www.ncbi.nlm.nih.gov/pubmed/34666806
http://dx.doi.org/10.1186/s13018-021-02764-0
work_keys_str_mv AT xuhong plasmalevelsofddimerandfibrindegradationproductareunreliablefordiagnosingperiprostheticjointinfectioninpatientsundergoingrerevisionarthroplasty
AT xiejinwei plasmalevelsofddimerandfibrindegradationproductareunreliablefordiagnosingperiprostheticjointinfectioninpatientsundergoingrerevisionarthroplasty
AT wangduan plasmalevelsofddimerandfibrindegradationproductareunreliablefordiagnosingperiprostheticjointinfectioninpatientsundergoingrerevisionarthroplasty
AT huangqiang plasmalevelsofddimerandfibrindegradationproductareunreliablefordiagnosingperiprostheticjointinfectioninpatientsundergoingrerevisionarthroplasty
AT huangzeyu plasmalevelsofddimerandfibrindegradationproductareunreliablefordiagnosingperiprostheticjointinfectioninpatientsundergoingrerevisionarthroplasty
AT zhouzongke plasmalevelsofddimerandfibrindegradationproductareunreliablefordiagnosingperiprostheticjointinfectioninpatientsundergoingrerevisionarthroplasty