Determination of reference intervals from a laboratory database of an academic clinical research unit in a tertiary care teaching hospital and an audit of out of range values

BACKGROUND: Abnormal laboratory values are a common reason for the exclusion of participants in clinical studies, increasing the recruitment time and cost during conduct. The use of sample-specific reference intervals (RIs) may help to address this issue. Hence, the present study derived site-specif...

Descripción completa

Detalles Bibliográficos
Autores principales: Figer, Brinal H., Raj, Jeffrey Pradeep, Thaker, Saket J., Gogtay, Nithya Jaideep, Thatte, Urmila Mukund
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8525794/
https://www.ncbi.nlm.nih.gov/pubmed/34760646
http://dx.doi.org/10.4103/picr.PICR_71_20
_version_ 1784585753902186496
author Figer, Brinal H.
Raj, Jeffrey Pradeep
Thaker, Saket J.
Gogtay, Nithya Jaideep
Thatte, Urmila Mukund
author_facet Figer, Brinal H.
Raj, Jeffrey Pradeep
Thaker, Saket J.
Gogtay, Nithya Jaideep
Thatte, Urmila Mukund
author_sort Figer, Brinal H.
collection PubMed
description BACKGROUND: Abnormal laboratory values are a common reason for the exclusion of participants in clinical studies, increasing the recruitment time and cost during conduct. The use of sample-specific reference intervals (RIs) may help to address this issue. Hence, the present study derived site-specific RIs using the department laboratory database and compare the proportion of “out of range” (OOR) values between the new and the old RIs used by the trial site. METHODS: Institutional ethics committee approval was obtained. Data for hematology and biochemistry parameters were analyzed. Normality was assessed and RIs computed using nonparametric method. Data were partitioned for gender and descriptive statistics applied for demographics. The OOR values based on new RIs were compared with old RIs using Chi-squared tests. Between gender OOR proportions compared using Chi-squared test (significance at P< 0.05). Post hoc analysis was performed with Beasley's technique. RESULTS: Data of 601 participants were analyzed. The median (Inter Quartile Range) age was 22 (47) years and 64.72% were male. New RIs for key parameters were: Haemoglobin (9.3–16.5 g/dl), alanine aminotransferase (11.4–47.74 U/I), aspartate aminotransferase (8.8–58 U/I), total bilirubin (0.27–1.4 mg/dl), and creatinine (0.59–1.36 mg/dl). Post partitioning, the RI for hemoglobin (g/dl) was lower (8.72–15.72) in females. The proportion of OOR values were lower with new RIs relative to old laboratory RIs (P < 0.0001). CONCLUSION: A reduction in the proportion of OORs and a change in the upper and lower bound laboratory intervals with new RIs emphasize the need for sample-specific ranges to prevent unnecessary exclusions of volunteers from trials.
format Online
Article
Text
id pubmed-8525794
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-85257942021-11-09 Determination of reference intervals from a laboratory database of an academic clinical research unit in a tertiary care teaching hospital and an audit of out of range values Figer, Brinal H. Raj, Jeffrey Pradeep Thaker, Saket J. Gogtay, Nithya Jaideep Thatte, Urmila Mukund Perspect Clin Res Original Article BACKGROUND: Abnormal laboratory values are a common reason for the exclusion of participants in clinical studies, increasing the recruitment time and cost during conduct. The use of sample-specific reference intervals (RIs) may help to address this issue. Hence, the present study derived site-specific RIs using the department laboratory database and compare the proportion of “out of range” (OOR) values between the new and the old RIs used by the trial site. METHODS: Institutional ethics committee approval was obtained. Data for hematology and biochemistry parameters were analyzed. Normality was assessed and RIs computed using nonparametric method. Data were partitioned for gender and descriptive statistics applied for demographics. The OOR values based on new RIs were compared with old RIs using Chi-squared tests. Between gender OOR proportions compared using Chi-squared test (significance at P< 0.05). Post hoc analysis was performed with Beasley's technique. RESULTS: Data of 601 participants were analyzed. The median (Inter Quartile Range) age was 22 (47) years and 64.72% were male. New RIs for key parameters were: Haemoglobin (9.3–16.5 g/dl), alanine aminotransferase (11.4–47.74 U/I), aspartate aminotransferase (8.8–58 U/I), total bilirubin (0.27–1.4 mg/dl), and creatinine (0.59–1.36 mg/dl). Post partitioning, the RI for hemoglobin (g/dl) was lower (8.72–15.72) in females. The proportion of OOR values were lower with new RIs relative to old laboratory RIs (P < 0.0001). CONCLUSION: A reduction in the proportion of OORs and a change in the upper and lower bound laboratory intervals with new RIs emphasize the need for sample-specific ranges to prevent unnecessary exclusions of volunteers from trials. Wolters Kluwer - Medknow 2021 2021-08-21 /pmc/articles/PMC8525794/ /pubmed/34760646 http://dx.doi.org/10.4103/picr.PICR_71_20 Text en Copyright: © 2021 Perspectives in Clinical Research https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Figer, Brinal H.
Raj, Jeffrey Pradeep
Thaker, Saket J.
Gogtay, Nithya Jaideep
Thatte, Urmila Mukund
Determination of reference intervals from a laboratory database of an academic clinical research unit in a tertiary care teaching hospital and an audit of out of range values
title Determination of reference intervals from a laboratory database of an academic clinical research unit in a tertiary care teaching hospital and an audit of out of range values
title_full Determination of reference intervals from a laboratory database of an academic clinical research unit in a tertiary care teaching hospital and an audit of out of range values
title_fullStr Determination of reference intervals from a laboratory database of an academic clinical research unit in a tertiary care teaching hospital and an audit of out of range values
title_full_unstemmed Determination of reference intervals from a laboratory database of an academic clinical research unit in a tertiary care teaching hospital and an audit of out of range values
title_short Determination of reference intervals from a laboratory database of an academic clinical research unit in a tertiary care teaching hospital and an audit of out of range values
title_sort determination of reference intervals from a laboratory database of an academic clinical research unit in a tertiary care teaching hospital and an audit of out of range values
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8525794/
https://www.ncbi.nlm.nih.gov/pubmed/34760646
http://dx.doi.org/10.4103/picr.PICR_71_20
work_keys_str_mv AT figerbrinalh determinationofreferenceintervalsfromalaboratorydatabaseofanacademicclinicalresearchunitinatertiarycareteachinghospitalandanauditofoutofrangevalues
AT rajjeffreypradeep determinationofreferenceintervalsfromalaboratorydatabaseofanacademicclinicalresearchunitinatertiarycareteachinghospitalandanauditofoutofrangevalues
AT thakersaketj determinationofreferenceintervalsfromalaboratorydatabaseofanacademicclinicalresearchunitinatertiarycareteachinghospitalandanauditofoutofrangevalues
AT gogtaynithyajaideep determinationofreferenceintervalsfromalaboratorydatabaseofanacademicclinicalresearchunitinatertiarycareteachinghospitalandanauditofoutofrangevalues
AT thatteurmilamukund determinationofreferenceintervalsfromalaboratorydatabaseofanacademicclinicalresearchunitinatertiarycareteachinghospitalandanauditofoutofrangevalues