Cargando…
Risk Assessment of Aerosol Generation During Vitreoretinal Surgery Using High Speed Imaging Amidst the COVID-19 Pandemic
PURPOSE: The purpose of this study was to discuss the propensity of aerosol and droplet generation during vitreoretinal surgery using high speed imaging amidst the coronavirus disease 2019 (COVID-19) pandemic. METHODS: In an experimental set up, various steps of vitreoretinal surgery were performed...
Autores principales: | Jayadev, Chaitra, Mochi Basavaraj, Thirumalesh, Pandey, Khushboo, Pinto, Roven, Pandey, Shashi Prabha, Basu, Saptarshi, Roy, Abhijit Sinha, Shetty, Rohit |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Association for Research in Vision and Ophthalmology
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8525865/ https://www.ncbi.nlm.nih.gov/pubmed/34647963 http://dx.doi.org/10.1167/tvst.10.12.17 |